Use of high frequency ultrasound to detect changes in skin integrity: An image evaluation validation procedure

Mary Jo Grap, Ruth Srednicki Burk, Valentina Lucas, Cindy Munro, Paul A. Wetzel, Christine M. Schubert

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Objectives: High frequency ultrasound (HFUS) scanning may be used for prevention, detection and monitoring of pressure ulcers in patients at risk and is amenable for portable, bedside use by a variety of clinicians. Limited data are available about the criteria to determine an ideal image or measures of tissue changes representative of tissue injury. We developed and evaluated criteria for overall image quality and measures of tissue integrity. Methods: In 40 mechanically ventilated adults in 3 ICUs, 241 HFUS sacral images were evaluated for agreement using criteria for overall image quality and tissue changes (dermal, hypodermal layer thickness and layer density). Results: HFUS sacral images (. N=. 241) were evaluated in three analyses and showed poor agreement in all three analyses using the specific criteria for global quality, however when criteria were collapsed agreement was good to substantial. Evaluator agreement for layer thickness and layer density was also good. Conclusions: A global rating is adequate for identifying good images. Agreement for measurements of layer thickness and density were also good and may be useful to identify early changes in tissue integrity leading to tissue injury. Additional data are needed concerning the association of changes in layer thickness and layer density to eventual tissue injury.

Original languageEnglish (US)
Pages (from-to)141-147
Number of pages7
JournalIntensive and Critical Care Nursing
Volume31
Issue number3
DOIs
StatePublished - Jan 1 2015
Externally publishedYes

Fingerprint

Skin
Wounds and Injuries
Pressure Ulcer

Keywords

  • Critical care
  • Evaluation
  • High frequency ultrasound
  • Pressure ulcers
  • Prevention

ASJC Scopus subject areas

  • Critical Care

Cite this

Use of high frequency ultrasound to detect changes in skin integrity : An image evaluation validation procedure. / Grap, Mary Jo; Burk, Ruth Srednicki; Lucas, Valentina; Munro, Cindy; Wetzel, Paul A.; Schubert, Christine M.

In: Intensive and Critical Care Nursing, Vol. 31, No. 3, 01.01.2015, p. 141-147.

Research output: Contribution to journalArticle

Grap, Mary Jo ; Burk, Ruth Srednicki ; Lucas, Valentina ; Munro, Cindy ; Wetzel, Paul A. ; Schubert, Christine M. / Use of high frequency ultrasound to detect changes in skin integrity : An image evaluation validation procedure. In: Intensive and Critical Care Nursing. 2015 ; Vol. 31, No. 3. pp. 141-147.
@article{79b2b490f56140b19adff497aa15353a,
title = "Use of high frequency ultrasound to detect changes in skin integrity: An image evaluation validation procedure",
abstract = "Objectives: High frequency ultrasound (HFUS) scanning may be used for prevention, detection and monitoring of pressure ulcers in patients at risk and is amenable for portable, bedside use by a variety of clinicians. Limited data are available about the criteria to determine an ideal image or measures of tissue changes representative of tissue injury. We developed and evaluated criteria for overall image quality and measures of tissue integrity. Methods: In 40 mechanically ventilated adults in 3 ICUs, 241 HFUS sacral images were evaluated for agreement using criteria for overall image quality and tissue changes (dermal, hypodermal layer thickness and layer density). Results: HFUS sacral images (. N=. 241) were evaluated in three analyses and showed poor agreement in all three analyses using the specific criteria for global quality, however when criteria were collapsed agreement was good to substantial. Evaluator agreement for layer thickness and layer density was also good. Conclusions: A global rating is adequate for identifying good images. Agreement for measurements of layer thickness and density were also good and may be useful to identify early changes in tissue integrity leading to tissue injury. Additional data are needed concerning the association of changes in layer thickness and layer density to eventual tissue injury.",
keywords = "Critical care, Evaluation, High frequency ultrasound, Pressure ulcers, Prevention",
author = "Grap, {Mary Jo} and Burk, {Ruth Srednicki} and Valentina Lucas and Cindy Munro and Wetzel, {Paul A.} and Schubert, {Christine M.}",
year = "2015",
month = "1",
day = "1",
doi = "10.1016/j.iccn.2014.08.002",
language = "English (US)",
volume = "31",
pages = "141--147",
journal = "Intensive and Critical Care Nursing",
issn = "0964-3397",
publisher = "Churchill Livingstone",
number = "3",

}

TY - JOUR

T1 - Use of high frequency ultrasound to detect changes in skin integrity

T2 - An image evaluation validation procedure

AU - Grap, Mary Jo

AU - Burk, Ruth Srednicki

AU - Lucas, Valentina

AU - Munro, Cindy

AU - Wetzel, Paul A.

AU - Schubert, Christine M.

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Objectives: High frequency ultrasound (HFUS) scanning may be used for prevention, detection and monitoring of pressure ulcers in patients at risk and is amenable for portable, bedside use by a variety of clinicians. Limited data are available about the criteria to determine an ideal image or measures of tissue changes representative of tissue injury. We developed and evaluated criteria for overall image quality and measures of tissue integrity. Methods: In 40 mechanically ventilated adults in 3 ICUs, 241 HFUS sacral images were evaluated for agreement using criteria for overall image quality and tissue changes (dermal, hypodermal layer thickness and layer density). Results: HFUS sacral images (. N=. 241) were evaluated in three analyses and showed poor agreement in all three analyses using the specific criteria for global quality, however when criteria were collapsed agreement was good to substantial. Evaluator agreement for layer thickness and layer density was also good. Conclusions: A global rating is adequate for identifying good images. Agreement for measurements of layer thickness and density were also good and may be useful to identify early changes in tissue integrity leading to tissue injury. Additional data are needed concerning the association of changes in layer thickness and layer density to eventual tissue injury.

AB - Objectives: High frequency ultrasound (HFUS) scanning may be used for prevention, detection and monitoring of pressure ulcers in patients at risk and is amenable for portable, bedside use by a variety of clinicians. Limited data are available about the criteria to determine an ideal image or measures of tissue changes representative of tissue injury. We developed and evaluated criteria for overall image quality and measures of tissue integrity. Methods: In 40 mechanically ventilated adults in 3 ICUs, 241 HFUS sacral images were evaluated for agreement using criteria for overall image quality and tissue changes (dermal, hypodermal layer thickness and layer density). Results: HFUS sacral images (. N=. 241) were evaluated in three analyses and showed poor agreement in all three analyses using the specific criteria for global quality, however when criteria were collapsed agreement was good to substantial. Evaluator agreement for layer thickness and layer density was also good. Conclusions: A global rating is adequate for identifying good images. Agreement for measurements of layer thickness and density were also good and may be useful to identify early changes in tissue integrity leading to tissue injury. Additional data are needed concerning the association of changes in layer thickness and layer density to eventual tissue injury.

KW - Critical care

KW - Evaluation

KW - High frequency ultrasound

KW - Pressure ulcers

KW - Prevention

UR - http://www.scopus.com/inward/record.url?scp=84930583534&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84930583534&partnerID=8YFLogxK

U2 - 10.1016/j.iccn.2014.08.002

DO - 10.1016/j.iccn.2014.08.002

M3 - Article

C2 - 25439140

AN - SCOPUS:84930583534

VL - 31

SP - 141

EP - 147

JO - Intensive and Critical Care Nursing

JF - Intensive and Critical Care Nursing

SN - 0964-3397

IS - 3

ER -