Use of a qualitative horse-side test to measure serum amyloid a in mares with experimentally induced ascending placentitis

Igor F. Canisso, Barry A. Ball, Carolyn Cray, Edward L. Squires, Mats H. Troedsson

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

The objectives of this study were to assess (1) changes in serum amyloid A (SAA) detected by a lateral flow device (LFD) in mares with experimental placentitis and (2) to assess the correlation of this assay with a quantitative immunoassay. Horse mares carrying normal pregnancies were assigned to a control group (n = 12) and to a group with experimentally induced ascending placentitis (n = 13). Blood samples were obtained immediately before inoculation and/or initial sampling for control mares and then daily for 12days or until abortion. Concentration of SAA was analyzed using a turbidometric immunoassay. Retrospectively, samples -9, -6, -3, and 0days from abortion (DFA) were analyzed. Day 0 was defined as the day of abortion for mares in the placentitis group and the last sampling day for mares in the control group. Based on the LFD results, there were significant differences between mares in the control group and mares in the group with experimentally induced placentitis (P < .0001). There was a progressive increase in SAA from -6 to 0 DFA determined by the LFD. There were no significant differences among examiners (P > .05). The results obtained using the commercial LFD were moderately correlated (ρ = 0.51; P < .001) with the concentrations of SAA determined by the turbidometric assay. Five of 91 LFDs (i.e., 5.5%) failed to provide any reading. The LFD for determination of SAA appears to be a useful tool for quick assessment of whether inflammation is present; however, quantitative evaluation may still be warranted.

Original languageEnglish (US)
Pages (from-to)54-59
Number of pages6
JournalJournal of Equine Veterinary Science
Volume35
Issue number1
DOIs
StatePublished - Jan 1 2015

Fingerprint

Serum Amyloid A Protein
amyloid
blood serum
Amyloid
mares
Horses
horses
Equipment and Supplies
abortion (animals)
Serum
Immunoassay
Control Groups
testing
immunoassays
Reading
sampling
Inflammation
Pregnancy
assays
inflammation

Keywords

  • Abortion
  • Diagnostic marker
  • Inflammation
  • Placentitis
  • SAA

ASJC Scopus subject areas

  • Equine

Cite this

Use of a qualitative horse-side test to measure serum amyloid a in mares with experimentally induced ascending placentitis. / Canisso, Igor F.; Ball, Barry A.; Cray, Carolyn; Squires, Edward L.; Troedsson, Mats H.

In: Journal of Equine Veterinary Science, Vol. 35, No. 1, 01.01.2015, p. 54-59.

Research output: Contribution to journalArticle

Canisso, Igor F. ; Ball, Barry A. ; Cray, Carolyn ; Squires, Edward L. ; Troedsson, Mats H. / Use of a qualitative horse-side test to measure serum amyloid a in mares with experimentally induced ascending placentitis. In: Journal of Equine Veterinary Science. 2015 ; Vol. 35, No. 1. pp. 54-59.
@article{bf07b0074e5846ca8f224c4fe81ccdb7,
title = "Use of a qualitative horse-side test to measure serum amyloid a in mares with experimentally induced ascending placentitis",
abstract = "The objectives of this study were to assess (1) changes in serum amyloid A (SAA) detected by a lateral flow device (LFD) in mares with experimental placentitis and (2) to assess the correlation of this assay with a quantitative immunoassay. Horse mares carrying normal pregnancies were assigned to a control group (n = 12) and to a group with experimentally induced ascending placentitis (n = 13). Blood samples were obtained immediately before inoculation and/or initial sampling for control mares and then daily for 12days or until abortion. Concentration of SAA was analyzed using a turbidometric immunoassay. Retrospectively, samples -9, -6, -3, and 0days from abortion (DFA) were analyzed. Day 0 was defined as the day of abortion for mares in the placentitis group and the last sampling day for mares in the control group. Based on the LFD results, there were significant differences between mares in the control group and mares in the group with experimentally induced placentitis (P < .0001). There was a progressive increase in SAA from -6 to 0 DFA determined by the LFD. There were no significant differences among examiners (P > .05). The results obtained using the commercial LFD were moderately correlated (ρ = 0.51; P < .001) with the concentrations of SAA determined by the turbidometric assay. Five of 91 LFDs (i.e., 5.5{\%}) failed to provide any reading. The LFD for determination of SAA appears to be a useful tool for quick assessment of whether inflammation is present; however, quantitative evaluation may still be warranted.",
keywords = "Abortion, Diagnostic marker, Inflammation, Placentitis, SAA",
author = "Canisso, {Igor F.} and Ball, {Barry A.} and Carolyn Cray and Squires, {Edward L.} and Troedsson, {Mats H.}",
year = "2015",
month = "1",
day = "1",
doi = "10.1016/j.jevs.2014.11.007",
language = "English (US)",
volume = "35",
pages = "54--59",
journal = "Journal of Equine Veterinary Science",
issn = "0737-0806",
publisher = "W.B. Saunders Ltd",
number = "1",

}

TY - JOUR

T1 - Use of a qualitative horse-side test to measure serum amyloid a in mares with experimentally induced ascending placentitis

AU - Canisso, Igor F.

AU - Ball, Barry A.

AU - Cray, Carolyn

AU - Squires, Edward L.

AU - Troedsson, Mats H.

PY - 2015/1/1

Y1 - 2015/1/1

N2 - The objectives of this study were to assess (1) changes in serum amyloid A (SAA) detected by a lateral flow device (LFD) in mares with experimental placentitis and (2) to assess the correlation of this assay with a quantitative immunoassay. Horse mares carrying normal pregnancies were assigned to a control group (n = 12) and to a group with experimentally induced ascending placentitis (n = 13). Blood samples were obtained immediately before inoculation and/or initial sampling for control mares and then daily for 12days or until abortion. Concentration of SAA was analyzed using a turbidometric immunoassay. Retrospectively, samples -9, -6, -3, and 0days from abortion (DFA) were analyzed. Day 0 was defined as the day of abortion for mares in the placentitis group and the last sampling day for mares in the control group. Based on the LFD results, there were significant differences between mares in the control group and mares in the group with experimentally induced placentitis (P < .0001). There was a progressive increase in SAA from -6 to 0 DFA determined by the LFD. There were no significant differences among examiners (P > .05). The results obtained using the commercial LFD were moderately correlated (ρ = 0.51; P < .001) with the concentrations of SAA determined by the turbidometric assay. Five of 91 LFDs (i.e., 5.5%) failed to provide any reading. The LFD for determination of SAA appears to be a useful tool for quick assessment of whether inflammation is present; however, quantitative evaluation may still be warranted.

AB - The objectives of this study were to assess (1) changes in serum amyloid A (SAA) detected by a lateral flow device (LFD) in mares with experimental placentitis and (2) to assess the correlation of this assay with a quantitative immunoassay. Horse mares carrying normal pregnancies were assigned to a control group (n = 12) and to a group with experimentally induced ascending placentitis (n = 13). Blood samples were obtained immediately before inoculation and/or initial sampling for control mares and then daily for 12days or until abortion. Concentration of SAA was analyzed using a turbidometric immunoassay. Retrospectively, samples -9, -6, -3, and 0days from abortion (DFA) were analyzed. Day 0 was defined as the day of abortion for mares in the placentitis group and the last sampling day for mares in the control group. Based on the LFD results, there were significant differences between mares in the control group and mares in the group with experimentally induced placentitis (P < .0001). There was a progressive increase in SAA from -6 to 0 DFA determined by the LFD. There were no significant differences among examiners (P > .05). The results obtained using the commercial LFD were moderately correlated (ρ = 0.51; P < .001) with the concentrations of SAA determined by the turbidometric assay. Five of 91 LFDs (i.e., 5.5%) failed to provide any reading. The LFD for determination of SAA appears to be a useful tool for quick assessment of whether inflammation is present; however, quantitative evaluation may still be warranted.

KW - Abortion

KW - Diagnostic marker

KW - Inflammation

KW - Placentitis

KW - SAA

UR - http://www.scopus.com/inward/record.url?scp=84925122151&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84925122151&partnerID=8YFLogxK

U2 - 10.1016/j.jevs.2014.11.007

DO - 10.1016/j.jevs.2014.11.007

M3 - Article

AN - SCOPUS:84925122151

VL - 35

SP - 54

EP - 59

JO - Journal of Equine Veterinary Science

JF - Journal of Equine Veterinary Science

SN - 0737-0806

IS - 1

ER -