Ultraviolet powder versus ultraviolet gel for assessing environmental cleaning

Luisa Munoz-Price, Yovanit Fajardo-Aquino, Kristopher Arheart

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

We compared cleaning rates associated with use of a white ultraviolet (UV) powder versus a transparent UV gel among units with various degrees of previous experience with UV powder. The study outcome was the presence of discordant cleaning (removal of powder without the removal of gel, or vice versa). We found higher frequency of discordance in high-experience units (31%) than in no-experience units (8%) (P<001). In 92% of discordant findings, the powder was removed but not the gel (P<.001). These findings suggest preferential cleaning of visible UV targets among units with high levels of previous experience with powder.

Original languageEnglish
Pages (from-to)192-195
Number of pages4
JournalInfection Control and Hospital Epidemiology
Volume33
Issue number2
DOIs
StatePublished - Feb 1 2012

Fingerprint

Powders
Gels
Outcome Assessment (Health Care)

ASJC Scopus subject areas

  • Microbiology (medical)
  • Epidemiology
  • Infectious Diseases

Cite this

Ultraviolet powder versus ultraviolet gel for assessing environmental cleaning. / Munoz-Price, Luisa; Fajardo-Aquino, Yovanit; Arheart, Kristopher.

In: Infection Control and Hospital Epidemiology, Vol. 33, No. 2, 01.02.2012, p. 192-195.

Research output: Contribution to journalArticle

Munoz-Price, Luisa ; Fajardo-Aquino, Yovanit ; Arheart, Kristopher. / Ultraviolet powder versus ultraviolet gel for assessing environmental cleaning. In: Infection Control and Hospital Epidemiology. 2012 ; Vol. 33, No. 2. pp. 192-195.
@article{6d43a7d636704c27bdc485c4a564f9c1,
title = "Ultraviolet powder versus ultraviolet gel for assessing environmental cleaning",
abstract = "We compared cleaning rates associated with use of a white ultraviolet (UV) powder versus a transparent UV gel among units with various degrees of previous experience with UV powder. The study outcome was the presence of discordant cleaning (removal of powder without the removal of gel, or vice versa). We found higher frequency of discordance in high-experience units (31{\%}) than in no-experience units (8{\%}) (P<001). In 92{\%} of discordant findings, the powder was removed but not the gel (P<.001). These findings suggest preferential cleaning of visible UV targets among units with high levels of previous experience with powder.",
author = "Luisa Munoz-Price and Yovanit Fajardo-Aquino and Kristopher Arheart",
year = "2012",
month = "2",
day = "1",
doi = "10.1086/663713",
language = "English",
volume = "33",
pages = "192--195",
journal = "Infection Control and Hospital Epidemiology",
issn = "0899-823X",
publisher = "University of Chicago Press",
number = "2",

}

TY - JOUR

T1 - Ultraviolet powder versus ultraviolet gel for assessing environmental cleaning

AU - Munoz-Price, Luisa

AU - Fajardo-Aquino, Yovanit

AU - Arheart, Kristopher

PY - 2012/2/1

Y1 - 2012/2/1

N2 - We compared cleaning rates associated with use of a white ultraviolet (UV) powder versus a transparent UV gel among units with various degrees of previous experience with UV powder. The study outcome was the presence of discordant cleaning (removal of powder without the removal of gel, or vice versa). We found higher frequency of discordance in high-experience units (31%) than in no-experience units (8%) (P<001). In 92% of discordant findings, the powder was removed but not the gel (P<.001). These findings suggest preferential cleaning of visible UV targets among units with high levels of previous experience with powder.

AB - We compared cleaning rates associated with use of a white ultraviolet (UV) powder versus a transparent UV gel among units with various degrees of previous experience with UV powder. The study outcome was the presence of discordant cleaning (removal of powder without the removal of gel, or vice versa). We found higher frequency of discordance in high-experience units (31%) than in no-experience units (8%) (P<001). In 92% of discordant findings, the powder was removed but not the gel (P<.001). These findings suggest preferential cleaning of visible UV targets among units with high levels of previous experience with powder.

UR - http://www.scopus.com/inward/record.url?scp=84855527006&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84855527006&partnerID=8YFLogxK

U2 - 10.1086/663713

DO - 10.1086/663713

M3 - Article

C2 - 22227990

AN - SCOPUS:84855527006

VL - 33

SP - 192

EP - 195

JO - Infection Control and Hospital Epidemiology

JF - Infection Control and Hospital Epidemiology

SN - 0899-823X

IS - 2