Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar

Thomas T. Lee, Barth A Green, David R. Petrin

Research output: Contribution to journalArticle

59 Citations (Scopus)

Abstract

Study Design. A retrospective review of a clinical series. Objective. To evaluate the use of a rigid cervical collar alone as the treatment for stable Jefferson fracture, and to devise an algorithm for treatment of Jefferson fracture with or without an associated cervical injury. Summary of Background Data. The traditional treatment for Jefferson fracture, if there is no indication for surgery, is immobilization by halo vesst. Because halo vest placement is associated with intracranial infection and a significant degree if patient discomfort, slightly less rigid forms of externa immobilization may be useful for the treatment of stable Jefferson fractures. No standard protocol calling for the use of one form of stabilization device has been reported. Materials. The medical records and radiographs of 16 consecutive patients with Jefferson fracture during a 2-year period were reviewed. Each patient underwent a complete cervical radiograph series and a computed tomographic scan. The mean C1 lateral mass displacement was 1.8 mm. Cervical spine radiographs, including lateral flexion-extension views were obtained 10 to 12 weeks after injury before the removal of an external immobilization device. Results. Of these 16 patients, 1 sustained a complete injury, and 7 sustained an incomplete injury. Eight patients were neurologically intact. Twelve patients sustained a stable Jefferson fracture and were treated with a rigid cervical collar (Miami-J collar [Jerome Medical, Moorestown, NJ]) alone from 10 to 12 weeks. The patient sustaining the complete neurologic injury died of multisystem trauma. All 15 live patients showed no instability on their follow-up plain radiographs before the removal of an external stabilization device. Six patients underwent further plain radiographs approximately 1 year after the fracture and similarly demonstrated no instability. Conclusions. Isolated stable burst fracture of the atlas can be treated effectively with a rigid cervical collar alone for 10 to 12 weeks with good neurologic recovery and segmental stability. Unstable Jefferson fractures with concurrent unstable fracture of other cervical vertebrae, especially C2, requires surgical stabilization.

Original languageEnglish
Pages (from-to)1963-1967
Number of pages5
JournalSpine
Volume23
Issue number18
DOIs
StatePublished - Sep 15 1998
Externally publishedYes

Fingerprint

Atlases
Immobilization
Wounds and Injuries
Therapeutics
Equipment and Supplies
Nervous System Trauma
Cervical Vertebrae
Nervous System
Medical Records
Spine

Keywords

  • Atlas fracture
  • Cervical collar
  • Immobilization
  • Jefferson fracture
  • Spinal trauma

ASJC Scopus subject areas

  • Physiology
  • Clinical Neurology
  • Orthopedics and Sports Medicine

Cite this

Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar. / Lee, Thomas T.; Green, Barth A; Petrin, David R.

In: Spine, Vol. 23, No. 18, 15.09.1998, p. 1963-1967.

Research output: Contribution to journalArticle

Lee, Thomas T. ; Green, Barth A ; Petrin, David R. / Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar. In: Spine. 1998 ; Vol. 23, No. 18. pp. 1963-1967.
@article{d86bc79de34a411794ae03db3392ac2b,
title = "Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar",
abstract = "Study Design. A retrospective review of a clinical series. Objective. To evaluate the use of a rigid cervical collar alone as the treatment for stable Jefferson fracture, and to devise an algorithm for treatment of Jefferson fracture with or without an associated cervical injury. Summary of Background Data. The traditional treatment for Jefferson fracture, if there is no indication for surgery, is immobilization by halo vesst. Because halo vest placement is associated with intracranial infection and a significant degree if patient discomfort, slightly less rigid forms of externa immobilization may be useful for the treatment of stable Jefferson fractures. No standard protocol calling for the use of one form of stabilization device has been reported. Materials. The medical records and radiographs of 16 consecutive patients with Jefferson fracture during a 2-year period were reviewed. Each patient underwent a complete cervical radiograph series and a computed tomographic scan. The mean C1 lateral mass displacement was 1.8 mm. Cervical spine radiographs, including lateral flexion-extension views were obtained 10 to 12 weeks after injury before the removal of an external immobilization device. Results. Of these 16 patients, 1 sustained a complete injury, and 7 sustained an incomplete injury. Eight patients were neurologically intact. Twelve patients sustained a stable Jefferson fracture and were treated with a rigid cervical collar (Miami-J collar [Jerome Medical, Moorestown, NJ]) alone from 10 to 12 weeks. The patient sustaining the complete neurologic injury died of multisystem trauma. All 15 live patients showed no instability on their follow-up plain radiographs before the removal of an external stabilization device. Six patients underwent further plain radiographs approximately 1 year after the fracture and similarly demonstrated no instability. Conclusions. Isolated stable burst fracture of the atlas can be treated effectively with a rigid cervical collar alone for 10 to 12 weeks with good neurologic recovery and segmental stability. Unstable Jefferson fractures with concurrent unstable fracture of other cervical vertebrae, especially C2, requires surgical stabilization.",
keywords = "Atlas fracture, Cervical collar, Immobilization, Jefferson fracture, Spinal trauma",
author = "Lee, {Thomas T.} and Green, {Barth A} and Petrin, {David R.}",
year = "1998",
month = "9",
day = "15",
doi = "10.1097/00007632-199809150-00008",
language = "English",
volume = "23",
pages = "1963--1967",
journal = "Spine",
issn = "0362-2436",
publisher = "Lippincott Williams and Wilkins",
number = "18",

}

TY - JOUR

T1 - Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar

AU - Lee, Thomas T.

AU - Green, Barth A

AU - Petrin, David R.

PY - 1998/9/15

Y1 - 1998/9/15

N2 - Study Design. A retrospective review of a clinical series. Objective. To evaluate the use of a rigid cervical collar alone as the treatment for stable Jefferson fracture, and to devise an algorithm for treatment of Jefferson fracture with or without an associated cervical injury. Summary of Background Data. The traditional treatment for Jefferson fracture, if there is no indication for surgery, is immobilization by halo vesst. Because halo vest placement is associated with intracranial infection and a significant degree if patient discomfort, slightly less rigid forms of externa immobilization may be useful for the treatment of stable Jefferson fractures. No standard protocol calling for the use of one form of stabilization device has been reported. Materials. The medical records and radiographs of 16 consecutive patients with Jefferson fracture during a 2-year period were reviewed. Each patient underwent a complete cervical radiograph series and a computed tomographic scan. The mean C1 lateral mass displacement was 1.8 mm. Cervical spine radiographs, including lateral flexion-extension views were obtained 10 to 12 weeks after injury before the removal of an external immobilization device. Results. Of these 16 patients, 1 sustained a complete injury, and 7 sustained an incomplete injury. Eight patients were neurologically intact. Twelve patients sustained a stable Jefferson fracture and were treated with a rigid cervical collar (Miami-J collar [Jerome Medical, Moorestown, NJ]) alone from 10 to 12 weeks. The patient sustaining the complete neurologic injury died of multisystem trauma. All 15 live patients showed no instability on their follow-up plain radiographs before the removal of an external stabilization device. Six patients underwent further plain radiographs approximately 1 year after the fracture and similarly demonstrated no instability. Conclusions. Isolated stable burst fracture of the atlas can be treated effectively with a rigid cervical collar alone for 10 to 12 weeks with good neurologic recovery and segmental stability. Unstable Jefferson fractures with concurrent unstable fracture of other cervical vertebrae, especially C2, requires surgical stabilization.

AB - Study Design. A retrospective review of a clinical series. Objective. To evaluate the use of a rigid cervical collar alone as the treatment for stable Jefferson fracture, and to devise an algorithm for treatment of Jefferson fracture with or without an associated cervical injury. Summary of Background Data. The traditional treatment for Jefferson fracture, if there is no indication for surgery, is immobilization by halo vesst. Because halo vest placement is associated with intracranial infection and a significant degree if patient discomfort, slightly less rigid forms of externa immobilization may be useful for the treatment of stable Jefferson fractures. No standard protocol calling for the use of one form of stabilization device has been reported. Materials. The medical records and radiographs of 16 consecutive patients with Jefferson fracture during a 2-year period were reviewed. Each patient underwent a complete cervical radiograph series and a computed tomographic scan. The mean C1 lateral mass displacement was 1.8 mm. Cervical spine radiographs, including lateral flexion-extension views were obtained 10 to 12 weeks after injury before the removal of an external immobilization device. Results. Of these 16 patients, 1 sustained a complete injury, and 7 sustained an incomplete injury. Eight patients were neurologically intact. Twelve patients sustained a stable Jefferson fracture and were treated with a rigid cervical collar (Miami-J collar [Jerome Medical, Moorestown, NJ]) alone from 10 to 12 weeks. The patient sustaining the complete neurologic injury died of multisystem trauma. All 15 live patients showed no instability on their follow-up plain radiographs before the removal of an external stabilization device. Six patients underwent further plain radiographs approximately 1 year after the fracture and similarly demonstrated no instability. Conclusions. Isolated stable burst fracture of the atlas can be treated effectively with a rigid cervical collar alone for 10 to 12 weeks with good neurologic recovery and segmental stability. Unstable Jefferson fractures with concurrent unstable fracture of other cervical vertebrae, especially C2, requires surgical stabilization.

KW - Atlas fracture

KW - Cervical collar

KW - Immobilization

KW - Jefferson fracture

KW - Spinal trauma

UR - http://www.scopus.com/inward/record.url?scp=0032530543&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032530543&partnerID=8YFLogxK

U2 - 10.1097/00007632-199809150-00008

DO - 10.1097/00007632-199809150-00008

M3 - Article

C2 - 9779528

AN - SCOPUS:0032530543

VL - 23

SP - 1963

EP - 1967

JO - Spine

JF - Spine

SN - 0362-2436

IS - 18

ER -