TY - JOUR
T1 - Thoracoabdominal compression and respiratory system compliance in HIV- infected infants
AU - Platzker, Arnold C.G.
AU - Colin, Andrew A.
AU - Chen, Xin C.
AU - Hiatt, Peter
AU - Hunter, Janice
AU - Koumbourlis, Anatassios C.
AU - Schluchter, Mark D.
AU - Ting, Andrew
AU - Wohl, Mary Ellen
PY - 2000/1/1
Y1 - 2000/1/1
N2 - The thoracoabdominal compression technique (TAC) is used to measure expiratory flow in infants. We investigated whether TAC caused a change in total thoracic compliance (Crs), resistance (Rrs), and respiratory system time constant (Trs). We studied 41 infants (mean age, 12.4 mo; SD, 7.5) from five centers studying longitudinal lung and cardiovascular function of infants from HIV-infected mothers. We measured Crs, Rrs, and Trs before and after TAC. Changes in Crs, Rrs, and Trs after TAC were not dependent on the length of time since TAC. Crs and Trs were reduced after TAC, p = 0.013 and p = 0.003, respectively, whereas Rrs did not change. When compared with uninfected infants, HIV-infected infants had a larger post-pre TAC percent decline in Crs (p = 0.003) and a post-pre TAC rise in mean Rrs (p = 0.03). These differences remained significant after adjusting for sex and age. When performing infant pulmonary function testing, TAC itself produces a temporary decrease in Crs and Trs that is more significant in infants at risk for abnormal lung volume or compliance. Therefore, the sequence of performing the infant lung function parameters should be the same each time the testing is repeated with TAC as the last parameter tested at each testing session.
AB - The thoracoabdominal compression technique (TAC) is used to measure expiratory flow in infants. We investigated whether TAC caused a change in total thoracic compliance (Crs), resistance (Rrs), and respiratory system time constant (Trs). We studied 41 infants (mean age, 12.4 mo; SD, 7.5) from five centers studying longitudinal lung and cardiovascular function of infants from HIV-infected mothers. We measured Crs, Rrs, and Trs before and after TAC. Changes in Crs, Rrs, and Trs after TAC were not dependent on the length of time since TAC. Crs and Trs were reduced after TAC, p = 0.013 and p = 0.003, respectively, whereas Rrs did not change. When compared with uninfected infants, HIV-infected infants had a larger post-pre TAC percent decline in Crs (p = 0.003) and a post-pre TAC rise in mean Rrs (p = 0.03). These differences remained significant after adjusting for sex and age. When performing infant pulmonary function testing, TAC itself produces a temporary decrease in Crs and Trs that is more significant in infants at risk for abnormal lung volume or compliance. Therefore, the sequence of performing the infant lung function parameters should be the same each time the testing is repeated with TAC as the last parameter tested at each testing session.
UR - http://www.scopus.com/inward/record.url?scp=0034126092&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034126092&partnerID=8YFLogxK
U2 - 10.1164/ajrccm.161.5.9902066
DO - 10.1164/ajrccm.161.5.9902066
M3 - Article
C2 - 10806156
AN - SCOPUS:0034126092
VL - 161
SP - 1567
EP - 1571
JO - American Journal of Respiratory and Critical Care Medicine
JF - American Journal of Respiratory and Critical Care Medicine
SN - 1073-449X
IS - 5
ER -