T1 - The use of Bowman's layer vertical topographic thickness map in the diagnosis of keratoconus
AU - Abou Shousha, Mohamed
AU - Perez, Victor L.
AU - Fraga Santini Canto, Ana Paula
AU - Vaddavalli, Pravin K.
AU - Sayyad, Fouad E.
AU - Cabot, Florence
AU - Feuer, William J.
AU - Wang, Jianhua
AU - Yoo, Sonia H.
N1 - Copyright:
Copyright 2014 Elsevier B.V., All rights reserved.
PY - 2014/5
Y1 - 2014/5
N2 - Purpose To evaluate the use of Bowman's layer (BL) vertical topographic thickness maps in diagnosing keratoconus (KC). Design Prospective, case control, interventional case series. Participants A total of 42 eyes: 22 eyes of 15 normal subjects and 20 eyes of 15 patients with KC. Intervention Bowman's layer 2-dimensional 9-mm vertical topographic thickness maps were created using custom-made ultra high-resolution optical coherence tomography. Main Outcome Measures Bowman's layer average and minimum thicknesses of the inferior half of the cornea, Bowman's ectasia index (BEI; defined as BL minimum thickness of the inferior half of the cornea divided by BL average thickness of the superior half of the cornea multiplied by 100), BEI-Max (defined as BL minimum thickness of the inferior half of the cornea divided by BL maximum thickness of the superior half of the cornea multiplied by 100), keratometric astigmatism (Ast-K) of patients with KC, and average keratometric (Avg-K) readings. Results In patients with KC, BL vertical thickness maps disclosed localized relative inferior thinning of the BL. Inferior BL average thickness (normal = 15±2, KC = 12±3 μm), inferior BL minimum thickness (normal = 13±2, KC = 7±3 μm), BEI (normal = 91±7, KC = 48±14), and BEI-Max (normal = 75±8; KC = 40±13) all showed highly significant differences in KC compared with normal subjects (P<0.001). Receiver operating characteristic (ROC) curve analysis showed excellent predictive accuracy for BEI and BEI-Max with 100% sensitivity and specificity (area under the curve [AUC] of 1) with cutoff values of 80 and 60, respectively. The AUC of inferior BL average thickness and minimum thickness were 0.87 and 0.96 with a sensitivity of 80% and 93%, respectively, and a specificity of 93% and 93%, respectively. Inferior BL average thickness, inferior BL minimum thickness, BEI, and BEI-Max correlated highly to Ast-K (R = -0.72, -0.82, -0.84, and -0.82, respectively; P<0.001) and to Avg-K (R = -0.62, P<0.001; R = -0.59, P = 0.001; R = -0.60, P<0.001; and R = -0.59, P = 0.001, respectively). Conclusions Bowman's layer vertical topographic thickness maps of patients with KC disclose characteristic localized relative inferior thinning. Inferior BL average thickness, inferior BL minimum thickness, BEI, and BEI-Max are qualitative and quantitative indices for the diagnosis of KC that accurately correlate with the severity of KC. In our pilot study, BEI and BEI-Max showed excellent accuracy, sensitivity, and specificity in the diagnosis of KC.
AB - Purpose To evaluate the use of Bowman's layer (BL) vertical topographic thickness maps in diagnosing keratoconus (KC). Design Prospective, case control, interventional case series. Participants A total of 42 eyes: 22 eyes of 15 normal subjects and 20 eyes of 15 patients with KC. Intervention Bowman's layer 2-dimensional 9-mm vertical topographic thickness maps were created using custom-made ultra high-resolution optical coherence tomography. Main Outcome Measures Bowman's layer average and minimum thicknesses of the inferior half of the cornea, Bowman's ectasia index (BEI; defined as BL minimum thickness of the inferior half of the cornea divided by BL average thickness of the superior half of the cornea multiplied by 100), BEI-Max (defined as BL minimum thickness of the inferior half of the cornea divided by BL maximum thickness of the superior half of the cornea multiplied by 100), keratometric astigmatism (Ast-K) of patients with KC, and average keratometric (Avg-K) readings. Results In patients with KC, BL vertical thickness maps disclosed localized relative inferior thinning of the BL. Inferior BL average thickness (normal = 15±2, KC = 12±3 μm), inferior BL minimum thickness (normal = 13±2, KC = 7±3 μm), BEI (normal = 91±7, KC = 48±14), and BEI-Max (normal = 75±8; KC = 40±13) all showed highly significant differences in KC compared with normal subjects (P<0.001). Receiver operating characteristic (ROC) curve analysis showed excellent predictive accuracy for BEI and BEI-Max with 100% sensitivity and specificity (area under the curve [AUC] of 1) with cutoff values of 80 and 60, respectively. The AUC of inferior BL average thickness and minimum thickness were 0.87 and 0.96 with a sensitivity of 80% and 93%, respectively, and a specificity of 93% and 93%, respectively. Inferior BL average thickness, inferior BL minimum thickness, BEI, and BEI-Max correlated highly to Ast-K (R = -0.72, -0.82, -0.84, and -0.82, respectively; P<0.001) and to Avg-K (R = -0.62, P<0.001; R = -0.59, P = 0.001; R = -0.60, P<0.001; and R = -0.59, P = 0.001, respectively). Conclusions Bowman's layer vertical topographic thickness maps of patients with KC disclose characteristic localized relative inferior thinning. Inferior BL average thickness, inferior BL minimum thickness, BEI, and BEI-Max are qualitative and quantitative indices for the diagnosis of KC that accurately correlate with the severity of KC. In our pilot study, BEI and BEI-Max showed excellent accuracy, sensitivity, and specificity in the diagnosis of KC.
UR - http://www.scopus.com/inward/record.url?scp=84899925583&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84899925583&partnerID=8YFLogxK
U2 - 10.1016/j.ophtha.2013.11.034
DO - 10.1016/j.ophtha.2013.11.034
M3 - Article
C2 - 24468653
AN - SCOPUS:84899925583
VL - 121
SP - 988
EP - 993
JO - Ophthalmology
JF - Ophthalmology
SN - 0161-6420
IS - 5
ER -