The short-term blood biocompatibility of poly(hydroxyethyl methacrylate-co-methyl methacrylate) in an in vitro flow system measured by digital videomicroscopy.

N. P. Desai, J. A. Hubbell

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

An in vitro flow system for short-term blood biocompatibility testing of solution-castable polymeric biomaterials was developed. This system was relatively free of artefacts resulting from blood contact with materials other than the test material itself. In conjunction with epifluorescence videomicroscopy and digital image processing, this method provided a high resolution, quantitative, continuous analysis of platelet adhesion, aggregation, thrombus formation, and embolization on the biomaterial surface. This system was well suited for performing biochemical assays on post-contact blood for assessment of platelet activation and release as additional measures of the thrombogenicity of the test material. This method for biomaterials evaluation in vitro was demonstrated by a detailed examination of copolymers of hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA). Videomicroscopic analysis of fluorescently labelled platelets adhering per unit area of the polymer surface after 5 min of flow at a wall shear rate of 500 s-1 showed a dramatic decrease with increasing HEMA fraction in the polymer. The release of serotonin and thromboxane A2 by platelets decreased with increasing HEMA fraction. Reflection interference contrast microscopy was used to examine focal contacts of platelets on the copolymer surfaces as a qualitative measure of the platelet-surface interaction. A polymer-dependent gradation in contact extent and morphology was observed, ranging from large contacts on P(MMA) to none on P(HEMA).

Original languageEnglish
Pages (from-to)123-146
Number of pages24
JournalJournal of biomaterials science. Polymer edition
Volume1
Issue number2
StatePublished - Dec 1 1989
Externally publishedYes

Fingerprint

Video Microscopy
Platelets
Biocompatibility
Blood
Blood Platelets
Biocompatible Materials
Polymers
Biomaterials
Methacrylates
Interference Microscopy
Materials Testing
Copolymers
Thromboxane A2
Focal Adhesions
Platelet Activation
Platelet Aggregation
Artifacts
Serotonin
Thrombosis
Shear deformation

ASJC Scopus subject areas

  • Biophysics

Cite this

@article{e7f53cd2553b49e082d3a9f6c510f4e7,
title = "The short-term blood biocompatibility of poly(hydroxyethyl methacrylate-co-methyl methacrylate) in an in vitro flow system measured by digital videomicroscopy.",
abstract = "An in vitro flow system for short-term blood biocompatibility testing of solution-castable polymeric biomaterials was developed. This system was relatively free of artefacts resulting from blood contact with materials other than the test material itself. In conjunction with epifluorescence videomicroscopy and digital image processing, this method provided a high resolution, quantitative, continuous analysis of platelet adhesion, aggregation, thrombus formation, and embolization on the biomaterial surface. This system was well suited for performing biochemical assays on post-contact blood for assessment of platelet activation and release as additional measures of the thrombogenicity of the test material. This method for biomaterials evaluation in vitro was demonstrated by a detailed examination of copolymers of hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA). Videomicroscopic analysis of fluorescently labelled platelets adhering per unit area of the polymer surface after 5 min of flow at a wall shear rate of 500 s-1 showed a dramatic decrease with increasing HEMA fraction in the polymer. The release of serotonin and thromboxane A2 by platelets decreased with increasing HEMA fraction. Reflection interference contrast microscopy was used to examine focal contacts of platelets on the copolymer surfaces as a qualitative measure of the platelet-surface interaction. A polymer-dependent gradation in contact extent and morphology was observed, ranging from large contacts on P(MMA) to none on P(HEMA).",
author = "Desai, {N. P.} and Hubbell, {J. A.}",
year = "1989",
month = "12",
day = "1",
language = "English",
volume = "1",
pages = "123--146",
journal = "Journal of Biomaterials Science, Polymer Edition",
issn = "0920-5063",
publisher = "Taylor and Francis Ltd.",
number = "2",

}

TY - JOUR

T1 - The short-term blood biocompatibility of poly(hydroxyethyl methacrylate-co-methyl methacrylate) in an in vitro flow system measured by digital videomicroscopy.

AU - Desai, N. P.

AU - Hubbell, J. A.

PY - 1989/12/1

Y1 - 1989/12/1

N2 - An in vitro flow system for short-term blood biocompatibility testing of solution-castable polymeric biomaterials was developed. This system was relatively free of artefacts resulting from blood contact with materials other than the test material itself. In conjunction with epifluorescence videomicroscopy and digital image processing, this method provided a high resolution, quantitative, continuous analysis of platelet adhesion, aggregation, thrombus formation, and embolization on the biomaterial surface. This system was well suited for performing biochemical assays on post-contact blood for assessment of platelet activation and release as additional measures of the thrombogenicity of the test material. This method for biomaterials evaluation in vitro was demonstrated by a detailed examination of copolymers of hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA). Videomicroscopic analysis of fluorescently labelled platelets adhering per unit area of the polymer surface after 5 min of flow at a wall shear rate of 500 s-1 showed a dramatic decrease with increasing HEMA fraction in the polymer. The release of serotonin and thromboxane A2 by platelets decreased with increasing HEMA fraction. Reflection interference contrast microscopy was used to examine focal contacts of platelets on the copolymer surfaces as a qualitative measure of the platelet-surface interaction. A polymer-dependent gradation in contact extent and morphology was observed, ranging from large contacts on P(MMA) to none on P(HEMA).

AB - An in vitro flow system for short-term blood biocompatibility testing of solution-castable polymeric biomaterials was developed. This system was relatively free of artefacts resulting from blood contact with materials other than the test material itself. In conjunction with epifluorescence videomicroscopy and digital image processing, this method provided a high resolution, quantitative, continuous analysis of platelet adhesion, aggregation, thrombus formation, and embolization on the biomaterial surface. This system was well suited for performing biochemical assays on post-contact blood for assessment of platelet activation and release as additional measures of the thrombogenicity of the test material. This method for biomaterials evaluation in vitro was demonstrated by a detailed examination of copolymers of hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA). Videomicroscopic analysis of fluorescently labelled platelets adhering per unit area of the polymer surface after 5 min of flow at a wall shear rate of 500 s-1 showed a dramatic decrease with increasing HEMA fraction in the polymer. The release of serotonin and thromboxane A2 by platelets decreased with increasing HEMA fraction. Reflection interference contrast microscopy was used to examine focal contacts of platelets on the copolymer surfaces as a qualitative measure of the platelet-surface interaction. A polymer-dependent gradation in contact extent and morphology was observed, ranging from large contacts on P(MMA) to none on P(HEMA).

UR - http://www.scopus.com/inward/record.url?scp=0024869255&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024869255&partnerID=8YFLogxK

M3 - Article

C2 - 2488848

AN - SCOPUS:0024869255

VL - 1

SP - 123

EP - 146

JO - Journal of Biomaterials Science, Polymer Edition

JF - Journal of Biomaterials Science, Polymer Edition

SN - 0920-5063

IS - 2

ER -