The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device

Morey J. Kolber, Kristina Beekhuizen, Ming Shun S Cheng, Ira Fiebert

Research output: Contribution to journalArticle

48 Citations (Scopus)

Abstract

Although hand-held dynamometry is considered an objective method of measuring strength, the reliability of the procedure can be compromised by inadequate tester strength and insufficient stabilization of the dynamometer and subject. The purpose of this study was to investigate the test-retest reliability of a hand-held dynamometer with the use of a portable stabilization device while testing the shoulder internal and external rotator musculature. The isometric strength of the shoulder rotator musculature was tested twice in 30 asymptomatic adult volunteers (15 male and 15 female) between 18 and 63 years of age by using an intrasession design. Consistency of the testing protocol was maintained through the use of an arm stabilization apparatus, which fixed the arm in 30° of the scapular plane and a portable dynamometer stabilization device. Intraclass correlation coefficients (ICC's) were high, ranging from ICC (3,1) = 0.971-0.972 for the test-retest trials of internal and external rotation. There was no significant difference between sessions one and two for maximum internal rotation (p = 0.431) and maximum external rotation strength (p = 0.780). The results indicate that the testing protocol with stabilization device is a reliable method for measuring strength of the internal and external rotator shoulder musculature.

Original languageEnglish
Pages (from-to)119-124
Number of pages6
JournalPhysiotherapy Theory and Practice
Volume23
Issue number2
DOIs
StatePublished - Mar 1 2007

Fingerprint

Hand
Equipment and Supplies
Arm
Reproducibility of Results
Volunteers

ASJC Scopus subject areas

  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device. / Kolber, Morey J.; Beekhuizen, Kristina; Cheng, Ming Shun S; Fiebert, Ira.

In: Physiotherapy Theory and Practice, Vol. 23, No. 2, 01.03.2007, p. 119-124.

Research output: Contribution to journalArticle

@article{85e39a0dbaf948ccbb6c435d6fff89b5,
title = "The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device",
abstract = "Although hand-held dynamometry is considered an objective method of measuring strength, the reliability of the procedure can be compromised by inadequate tester strength and insufficient stabilization of the dynamometer and subject. The purpose of this study was to investigate the test-retest reliability of a hand-held dynamometer with the use of a portable stabilization device while testing the shoulder internal and external rotator musculature. The isometric strength of the shoulder rotator musculature was tested twice in 30 asymptomatic adult volunteers (15 male and 15 female) between 18 and 63 years of age by using an intrasession design. Consistency of the testing protocol was maintained through the use of an arm stabilization apparatus, which fixed the arm in 30° of the scapular plane and a portable dynamometer stabilization device. Intraclass correlation coefficients (ICC's) were high, ranging from ICC (3,1) = 0.971-0.972 for the test-retest trials of internal and external rotation. There was no significant difference between sessions one and two for maximum internal rotation (p = 0.431) and maximum external rotation strength (p = 0.780). The results indicate that the testing protocol with stabilization device is a reliable method for measuring strength of the internal and external rotator shoulder musculature.",
author = "Kolber, {Morey J.} and Kristina Beekhuizen and Cheng, {Ming Shun S} and Ira Fiebert",
year = "2007",
month = "3",
day = "1",
doi = "10.1080/09593980701213032",
language = "English",
volume = "23",
pages = "119--124",
journal = "Physiotherapy Theory and Practice",
issn = "0959-3985",
publisher = "Informa Healthcare",
number = "2",

}

TY - JOUR

T1 - The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device

AU - Kolber, Morey J.

AU - Beekhuizen, Kristina

AU - Cheng, Ming Shun S

AU - Fiebert, Ira

PY - 2007/3/1

Y1 - 2007/3/1

N2 - Although hand-held dynamometry is considered an objective method of measuring strength, the reliability of the procedure can be compromised by inadequate tester strength and insufficient stabilization of the dynamometer and subject. The purpose of this study was to investigate the test-retest reliability of a hand-held dynamometer with the use of a portable stabilization device while testing the shoulder internal and external rotator musculature. The isometric strength of the shoulder rotator musculature was tested twice in 30 asymptomatic adult volunteers (15 male and 15 female) between 18 and 63 years of age by using an intrasession design. Consistency of the testing protocol was maintained through the use of an arm stabilization apparatus, which fixed the arm in 30° of the scapular plane and a portable dynamometer stabilization device. Intraclass correlation coefficients (ICC's) were high, ranging from ICC (3,1) = 0.971-0.972 for the test-retest trials of internal and external rotation. There was no significant difference between sessions one and two for maximum internal rotation (p = 0.431) and maximum external rotation strength (p = 0.780). The results indicate that the testing protocol with stabilization device is a reliable method for measuring strength of the internal and external rotator shoulder musculature.

AB - Although hand-held dynamometry is considered an objective method of measuring strength, the reliability of the procedure can be compromised by inadequate tester strength and insufficient stabilization of the dynamometer and subject. The purpose of this study was to investigate the test-retest reliability of a hand-held dynamometer with the use of a portable stabilization device while testing the shoulder internal and external rotator musculature. The isometric strength of the shoulder rotator musculature was tested twice in 30 asymptomatic adult volunteers (15 male and 15 female) between 18 and 63 years of age by using an intrasession design. Consistency of the testing protocol was maintained through the use of an arm stabilization apparatus, which fixed the arm in 30° of the scapular plane and a portable dynamometer stabilization device. Intraclass correlation coefficients (ICC's) were high, ranging from ICC (3,1) = 0.971-0.972 for the test-retest trials of internal and external rotation. There was no significant difference between sessions one and two for maximum internal rotation (p = 0.431) and maximum external rotation strength (p = 0.780). The results indicate that the testing protocol with stabilization device is a reliable method for measuring strength of the internal and external rotator shoulder musculature.

UR - http://www.scopus.com/inward/record.url?scp=34249742657&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34249742657&partnerID=8YFLogxK

U2 - 10.1080/09593980701213032

DO - 10.1080/09593980701213032

M3 - Article

C2 - 17530541

AN - SCOPUS:34249742657

VL - 23

SP - 119

EP - 124

JO - Physiotherapy Theory and Practice

JF - Physiotherapy Theory and Practice

SN - 0959-3985

IS - 2

ER -