TH‐D‐M100F‐06: Surface Smoothing of a Tubular Structure Using a Non‐Shrinking Algorithm

Y. Chen, K. Paskalev, E. Horwitz, R. Price, M. Buyyounouski, C. ma, Alan Pollack

Research output: Contribution to journalArticle

Abstract

Purpose: The modeling of a 3D structure by interpolating a stack of 2D contours may result in an unrealistic faceted shape, even though each contour is smooth. A difficulty with geometric smoothing is that the surface can shrink after a number of iterations. This work investigates the use of a non‐shrinking smoothing algorithm in structure delineation for radiotherapy treatment planning. Materials and methods: The surface of a tubular structure is parameterized by an interpolating function using original contour data points in cylindrical coordinates. The center of the polar coordinates for each axial contour is placed on a smooth fitting function while the contour is still a single‐valued function. By interpolation the surface is re‐sampled into a set of evenly spaced vertices. In an iterative process each vertex is shifted by an average displacement vector from its neighbor vertices and scaled by a factor. Each step of iteration involves two shifts for every vertex with the scaling factor in opposite signs, in order to avoid shrinkage. The iterative process stops after a desired smoothness is achieved with all average displacement vectors smaller than a specified tolerance. This method is tested on five prostate IMRT cases. The axial contours of smoothed structure are displayed with the original contours for validation by three physicians. Results: The resulting surface appeared smooth in all projections. The physician approved the new contours for all five patients. The volume change for each structure was less than 2%. Treatment planning using smoothed CTVs and PTVs reduced the numbers of MU and MLC segments by 8 – 11%. Conclusions: A technique was developed for smoothing a structure surface constructed using 2D contours. The calculation was fast for 3D contouring. Our planning results suggested that unrealistically irregular target shapes can have adverse effects on dose conformity and delivery efficiency.

Original languageEnglish (US)
Pages (from-to)2637
Number of pages1
JournalMedical Physics
Volume34
Issue number6
DOIs
StatePublished - 2007
Externally publishedYes

Fingerprint

Physicians
Prostate
Radiotherapy
Therapeutics

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

TH‐D‐M100F‐06 : Surface Smoothing of a Tubular Structure Using a Non‐Shrinking Algorithm. / Chen, Y.; Paskalev, K.; Horwitz, E.; Price, R.; Buyyounouski, M.; ma, C.; Pollack, Alan.

In: Medical Physics, Vol. 34, No. 6, 2007, p. 2637.

Research output: Contribution to journalArticle

Chen, Y, Paskalev, K, Horwitz, E, Price, R, Buyyounouski, M, ma, C & Pollack, A 2007, 'TH‐D‐M100F‐06: Surface Smoothing of a Tubular Structure Using a Non‐Shrinking Algorithm', Medical Physics, vol. 34, no. 6, pp. 2637. https://doi.org/10.1118/1.2761706
Chen, Y. ; Paskalev, K. ; Horwitz, E. ; Price, R. ; Buyyounouski, M. ; ma, C. ; Pollack, Alan. / TH‐D‐M100F‐06 : Surface Smoothing of a Tubular Structure Using a Non‐Shrinking Algorithm. In: Medical Physics. 2007 ; Vol. 34, No. 6. pp. 2637.
@article{d10b02dd5c444b6fb0ab715ce6339e0d,
title = "TH‐D‐M100F‐06: Surface Smoothing of a Tubular Structure Using a Non‐Shrinking Algorithm",
abstract = "Purpose: The modeling of a 3D structure by interpolating a stack of 2D contours may result in an unrealistic faceted shape, even though each contour is smooth. A difficulty with geometric smoothing is that the surface can shrink after a number of iterations. This work investigates the use of a non‐shrinking smoothing algorithm in structure delineation for radiotherapy treatment planning. Materials and methods: The surface of a tubular structure is parameterized by an interpolating function using original contour data points in cylindrical coordinates. The center of the polar coordinates for each axial contour is placed on a smooth fitting function while the contour is still a single‐valued function. By interpolation the surface is re‐sampled into a set of evenly spaced vertices. In an iterative process each vertex is shifted by an average displacement vector from its neighbor vertices and scaled by a factor. Each step of iteration involves two shifts for every vertex with the scaling factor in opposite signs, in order to avoid shrinkage. The iterative process stops after a desired smoothness is achieved with all average displacement vectors smaller than a specified tolerance. This method is tested on five prostate IMRT cases. The axial contours of smoothed structure are displayed with the original contours for validation by three physicians. Results: The resulting surface appeared smooth in all projections. The physician approved the new contours for all five patients. The volume change for each structure was less than 2{\%}. Treatment planning using smoothed CTVs and PTVs reduced the numbers of MU and MLC segments by 8 – 11{\%}. Conclusions: A technique was developed for smoothing a structure surface constructed using 2D contours. The calculation was fast for 3D contouring. Our planning results suggested that unrealistically irregular target shapes can have adverse effects on dose conformity and delivery efficiency.",
author = "Y. Chen and K. Paskalev and E. Horwitz and R. Price and M. Buyyounouski and C. ma and Alan Pollack",
year = "2007",
doi = "10.1118/1.2761706",
language = "English (US)",
volume = "34",
pages = "2637",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - TH‐D‐M100F‐06

T2 - Surface Smoothing of a Tubular Structure Using a Non‐Shrinking Algorithm

AU - Chen, Y.

AU - Paskalev, K.

AU - Horwitz, E.

AU - Price, R.

AU - Buyyounouski, M.

AU - ma, C.

AU - Pollack, Alan

PY - 2007

Y1 - 2007

N2 - Purpose: The modeling of a 3D structure by interpolating a stack of 2D contours may result in an unrealistic faceted shape, even though each contour is smooth. A difficulty with geometric smoothing is that the surface can shrink after a number of iterations. This work investigates the use of a non‐shrinking smoothing algorithm in structure delineation for radiotherapy treatment planning. Materials and methods: The surface of a tubular structure is parameterized by an interpolating function using original contour data points in cylindrical coordinates. The center of the polar coordinates for each axial contour is placed on a smooth fitting function while the contour is still a single‐valued function. By interpolation the surface is re‐sampled into a set of evenly spaced vertices. In an iterative process each vertex is shifted by an average displacement vector from its neighbor vertices and scaled by a factor. Each step of iteration involves two shifts for every vertex with the scaling factor in opposite signs, in order to avoid shrinkage. The iterative process stops after a desired smoothness is achieved with all average displacement vectors smaller than a specified tolerance. This method is tested on five prostate IMRT cases. The axial contours of smoothed structure are displayed with the original contours for validation by three physicians. Results: The resulting surface appeared smooth in all projections. The physician approved the new contours for all five patients. The volume change for each structure was less than 2%. Treatment planning using smoothed CTVs and PTVs reduced the numbers of MU and MLC segments by 8 – 11%. Conclusions: A technique was developed for smoothing a structure surface constructed using 2D contours. The calculation was fast for 3D contouring. Our planning results suggested that unrealistically irregular target shapes can have adverse effects on dose conformity and delivery efficiency.

AB - Purpose: The modeling of a 3D structure by interpolating a stack of 2D contours may result in an unrealistic faceted shape, even though each contour is smooth. A difficulty with geometric smoothing is that the surface can shrink after a number of iterations. This work investigates the use of a non‐shrinking smoothing algorithm in structure delineation for radiotherapy treatment planning. Materials and methods: The surface of a tubular structure is parameterized by an interpolating function using original contour data points in cylindrical coordinates. The center of the polar coordinates for each axial contour is placed on a smooth fitting function while the contour is still a single‐valued function. By interpolation the surface is re‐sampled into a set of evenly spaced vertices. In an iterative process each vertex is shifted by an average displacement vector from its neighbor vertices and scaled by a factor. Each step of iteration involves two shifts for every vertex with the scaling factor in opposite signs, in order to avoid shrinkage. The iterative process stops after a desired smoothness is achieved with all average displacement vectors smaller than a specified tolerance. This method is tested on five prostate IMRT cases. The axial contours of smoothed structure are displayed with the original contours for validation by three physicians. Results: The resulting surface appeared smooth in all projections. The physician approved the new contours for all five patients. The volume change for each structure was less than 2%. Treatment planning using smoothed CTVs and PTVs reduced the numbers of MU and MLC segments by 8 – 11%. Conclusions: A technique was developed for smoothing a structure surface constructed using 2D contours. The calculation was fast for 3D contouring. Our planning results suggested that unrealistically irregular target shapes can have adverse effects on dose conformity and delivery efficiency.

UR - http://www.scopus.com/inward/record.url?scp=85024802997&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024802997&partnerID=8YFLogxK

U2 - 10.1118/1.2761706

DO - 10.1118/1.2761706

M3 - Article

AN - SCOPUS:85024802997

VL - 34

SP - 2637

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -