Termination criteria for jacked precast high-strength prestressed concrete pipe piles

Junwei Liu, Zhongmiao Zhang, Feng Yu, Qingda Yang

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Precast high-strength prestressed concrete pipe piles installed by the jacking method have received wide use as deep foundations in China. Adoption of appropriate termination criteria during installation is the key issue to ensure design capacity or avoid conservative design for jacked piles. A database including 1228 field load tests on jacked concrete pipe piles is collected in this study to establish empirical correlations between the final jacking force and the ultimate capacity. Using the pile slenderness ratio as the fundamental parameter, a total of 14 correlations are derived to apply for various categories of soil conditions. Among them, the ratio of pile capacity to jacking force for piles in stiff clay and firm clay exhibits the greatest magnitude and trend of increase with increasing pile slenderness ratio. Moreover, two jacked concrete pipe piles in silty clay are instrumented and load-tested as an independent case to examine the consistency of the proposed correlations. The two test piles are installed in accordance with a double-control termination criterion that involves the requirements of both final penetration and final jacking force. The load transfer behaviour of the piles has revealed that their performances satisfy all the design requirements.

Original languageEnglish
Pages (from-to)268-279
Number of pages12
JournalProceedings of the Institution of Civil Engineers: Geotechnical Engineering
Volume166
Issue number3
DOIs
StatePublished - Jun 1 2013

Fingerprint

Concrete pipe
Prestressed concrete
Piles
pile
pipe
Clay
clay
silty clay
penetration

Keywords

  • Field testing & monitoring
  • Geotechnical engineering
  • Piles & piling

ASJC Scopus subject areas

  • Earth and Planetary Sciences (miscellaneous)
  • Geotechnical Engineering and Engineering Geology

Cite this

Termination criteria for jacked precast high-strength prestressed concrete pipe piles. / Liu, Junwei; Zhang, Zhongmiao; Yu, Feng; Yang, Qingda.

In: Proceedings of the Institution of Civil Engineers: Geotechnical Engineering, Vol. 166, No. 3, 01.06.2013, p. 268-279.

Research output: Contribution to journalArticle

@article{16afd968a3e740c981245e4f67f24336,
title = "Termination criteria for jacked precast high-strength prestressed concrete pipe piles",
abstract = "Precast high-strength prestressed concrete pipe piles installed by the jacking method have received wide use as deep foundations in China. Adoption of appropriate termination criteria during installation is the key issue to ensure design capacity or avoid conservative design for jacked piles. A database including 1228 field load tests on jacked concrete pipe piles is collected in this study to establish empirical correlations between the final jacking force and the ultimate capacity. Using the pile slenderness ratio as the fundamental parameter, a total of 14 correlations are derived to apply for various categories of soil conditions. Among them, the ratio of pile capacity to jacking force for piles in stiff clay and firm clay exhibits the greatest magnitude and trend of increase with increasing pile slenderness ratio. Moreover, two jacked concrete pipe piles in silty clay are instrumented and load-tested as an independent case to examine the consistency of the proposed correlations. The two test piles are installed in accordance with a double-control termination criterion that involves the requirements of both final penetration and final jacking force. The load transfer behaviour of the piles has revealed that their performances satisfy all the design requirements.",
keywords = "Field testing & monitoring, Geotechnical engineering, Piles & piling",
author = "Junwei Liu and Zhongmiao Zhang and Feng Yu and Qingda Yang",
year = "2013",
month = "6",
day = "1",
doi = "10.1680/geng.10.00083",
language = "English",
volume = "166",
pages = "268--279",
journal = "Proceedings of the Institution of Civil Engineers: Geotechnical Engineering",
issn = "1353-2618",
publisher = "ICE Publishing Ltd.",
number = "3",

}

TY - JOUR

T1 - Termination criteria for jacked precast high-strength prestressed concrete pipe piles

AU - Liu, Junwei

AU - Zhang, Zhongmiao

AU - Yu, Feng

AU - Yang, Qingda

PY - 2013/6/1

Y1 - 2013/6/1

N2 - Precast high-strength prestressed concrete pipe piles installed by the jacking method have received wide use as deep foundations in China. Adoption of appropriate termination criteria during installation is the key issue to ensure design capacity or avoid conservative design for jacked piles. A database including 1228 field load tests on jacked concrete pipe piles is collected in this study to establish empirical correlations between the final jacking force and the ultimate capacity. Using the pile slenderness ratio as the fundamental parameter, a total of 14 correlations are derived to apply for various categories of soil conditions. Among them, the ratio of pile capacity to jacking force for piles in stiff clay and firm clay exhibits the greatest magnitude and trend of increase with increasing pile slenderness ratio. Moreover, two jacked concrete pipe piles in silty clay are instrumented and load-tested as an independent case to examine the consistency of the proposed correlations. The two test piles are installed in accordance with a double-control termination criterion that involves the requirements of both final penetration and final jacking force. The load transfer behaviour of the piles has revealed that their performances satisfy all the design requirements.

AB - Precast high-strength prestressed concrete pipe piles installed by the jacking method have received wide use as deep foundations in China. Adoption of appropriate termination criteria during installation is the key issue to ensure design capacity or avoid conservative design for jacked piles. A database including 1228 field load tests on jacked concrete pipe piles is collected in this study to establish empirical correlations between the final jacking force and the ultimate capacity. Using the pile slenderness ratio as the fundamental parameter, a total of 14 correlations are derived to apply for various categories of soil conditions. Among them, the ratio of pile capacity to jacking force for piles in stiff clay and firm clay exhibits the greatest magnitude and trend of increase with increasing pile slenderness ratio. Moreover, two jacked concrete pipe piles in silty clay are instrumented and load-tested as an independent case to examine the consistency of the proposed correlations. The two test piles are installed in accordance with a double-control termination criterion that involves the requirements of both final penetration and final jacking force. The load transfer behaviour of the piles has revealed that their performances satisfy all the design requirements.

KW - Field testing & monitoring

KW - Geotechnical engineering

KW - Piles & piling

UR - http://www.scopus.com/inward/record.url?scp=84885005826&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885005826&partnerID=8YFLogxK

U2 - 10.1680/geng.10.00083

DO - 10.1680/geng.10.00083

M3 - Article

AN - SCOPUS:84885005826

VL - 166

SP - 268

EP - 279

JO - Proceedings of the Institution of Civil Engineers: Geotechnical Engineering

JF - Proceedings of the Institution of Civil Engineers: Geotechnical Engineering

SN - 1353-2618

IS - 3

ER -