Simultaneous fundus imaging and optical coherence tomography of the mouse retina

Omer P. Kocaoglu, Stephen R. Uhlhorn, Eleut Hernandez, Roger A. Juarez, Russell Will, Jean-Marie A Parel, Fabrice Manns

Research output: Contribution to journalArticle

42 Citations (Scopus)

Abstract

PURPOSE. To develop a retinal imaging system suitable for routine examination or screening of mouse models and to demonstrate the feasibility of simultaneously acquiring fundus and optical coherence tomography (OCT) images. METHODS. The imaging system is composed of a photographic slit lamp for biomicroscopic examination of the fundus, an OCT interferometer, an OCT beam delivery system designed for the mouse eye, and a mouse positioning stage. Image acquisition was controlled with software that displays the fundus and OCT images in real time, and allows the user to control the position of the OCT beam spot on the fundus image display. The anesthetized mouse was placed in a cylindrical holder on the positioning stage, and a single operator adjusted the position of mouse. RESULTS. Fundus images and OCT scans were successfully acquired in both eyes of 8 C57BL/6 mice. Once the animal is anesthetized and placed in the holder, a typical imaging experiment takes less than 2 minutes. The retinal vasculature, pigmentation, nerve fiber arrangement, and optic nerve head were clearly visible on the fundus images. The quality of the OCT images was sufficient to allow measurement of the total, inner, and outer retinal thicknesses and to visualize the optic nerve head excavation. CONCLUSIONS. The study demonstrates the feasibility of acquiring simultaneous fundus and OCT images of the mouse retina, by a single operator, in a manner suitable for routine evaluation of mouse models of retinal disease.

Original languageEnglish
Pages (from-to)1283-1289
Number of pages7
JournalInvestigative Ophthalmology and Visual Science
Volume48
Issue number3
DOIs
StatePublished - Mar 1 2007

Fingerprint

Optical Coherence Tomography
Retina
Optic Disk
Retinal Diseases
Pigmentation
Feasibility Studies
Inbred C57BL Mouse
Nerve Fibers
Software

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Simultaneous fundus imaging and optical coherence tomography of the mouse retina. / Kocaoglu, Omer P.; Uhlhorn, Stephen R.; Hernandez, Eleut; Juarez, Roger A.; Will, Russell; Parel, Jean-Marie A; Manns, Fabrice.

In: Investigative Ophthalmology and Visual Science, Vol. 48, No. 3, 01.03.2007, p. 1283-1289.

Research output: Contribution to journalArticle

Kocaoglu, Omer P. ; Uhlhorn, Stephen R. ; Hernandez, Eleut ; Juarez, Roger A. ; Will, Russell ; Parel, Jean-Marie A ; Manns, Fabrice. / Simultaneous fundus imaging and optical coherence tomography of the mouse retina. In: Investigative Ophthalmology and Visual Science. 2007 ; Vol. 48, No. 3. pp. 1283-1289.
@article{f1ccec891003465c80c9102b405d2abd,
title = "Simultaneous fundus imaging and optical coherence tomography of the mouse retina",
abstract = "PURPOSE. To develop a retinal imaging system suitable for routine examination or screening of mouse models and to demonstrate the feasibility of simultaneously acquiring fundus and optical coherence tomography (OCT) images. METHODS. The imaging system is composed of a photographic slit lamp for biomicroscopic examination of the fundus, an OCT interferometer, an OCT beam delivery system designed for the mouse eye, and a mouse positioning stage. Image acquisition was controlled with software that displays the fundus and OCT images in real time, and allows the user to control the position of the OCT beam spot on the fundus image display. The anesthetized mouse was placed in a cylindrical holder on the positioning stage, and a single operator adjusted the position of mouse. RESULTS. Fundus images and OCT scans were successfully acquired in both eyes of 8 C57BL/6 mice. Once the animal is anesthetized and placed in the holder, a typical imaging experiment takes less than 2 minutes. The retinal vasculature, pigmentation, nerve fiber arrangement, and optic nerve head were clearly visible on the fundus images. The quality of the OCT images was sufficient to allow measurement of the total, inner, and outer retinal thicknesses and to visualize the optic nerve head excavation. CONCLUSIONS. The study demonstrates the feasibility of acquiring simultaneous fundus and OCT images of the mouse retina, by a single operator, in a manner suitable for routine evaluation of mouse models of retinal disease.",
author = "Kocaoglu, {Omer P.} and Uhlhorn, {Stephen R.} and Eleut Hernandez and Juarez, {Roger A.} and Russell Will and Parel, {Jean-Marie A} and Fabrice Manns",
year = "2007",
month = "3",
day = "1",
doi = "10.1167/iovs.06-0732",
language = "English",
volume = "48",
pages = "1283--1289",
journal = "Investigative Ophthalmology and Visual Science",
issn = "0146-0404",
publisher = "Association for Research in Vision and Ophthalmology Inc.",
number = "3",

}

TY - JOUR

T1 - Simultaneous fundus imaging and optical coherence tomography of the mouse retina

AU - Kocaoglu, Omer P.

AU - Uhlhorn, Stephen R.

AU - Hernandez, Eleut

AU - Juarez, Roger A.

AU - Will, Russell

AU - Parel, Jean-Marie A

AU - Manns, Fabrice

PY - 2007/3/1

Y1 - 2007/3/1

N2 - PURPOSE. To develop a retinal imaging system suitable for routine examination or screening of mouse models and to demonstrate the feasibility of simultaneously acquiring fundus and optical coherence tomography (OCT) images. METHODS. The imaging system is composed of a photographic slit lamp for biomicroscopic examination of the fundus, an OCT interferometer, an OCT beam delivery system designed for the mouse eye, and a mouse positioning stage. Image acquisition was controlled with software that displays the fundus and OCT images in real time, and allows the user to control the position of the OCT beam spot on the fundus image display. The anesthetized mouse was placed in a cylindrical holder on the positioning stage, and a single operator adjusted the position of mouse. RESULTS. Fundus images and OCT scans were successfully acquired in both eyes of 8 C57BL/6 mice. Once the animal is anesthetized and placed in the holder, a typical imaging experiment takes less than 2 minutes. The retinal vasculature, pigmentation, nerve fiber arrangement, and optic nerve head were clearly visible on the fundus images. The quality of the OCT images was sufficient to allow measurement of the total, inner, and outer retinal thicknesses and to visualize the optic nerve head excavation. CONCLUSIONS. The study demonstrates the feasibility of acquiring simultaneous fundus and OCT images of the mouse retina, by a single operator, in a manner suitable for routine evaluation of mouse models of retinal disease.

AB - PURPOSE. To develop a retinal imaging system suitable for routine examination or screening of mouse models and to demonstrate the feasibility of simultaneously acquiring fundus and optical coherence tomography (OCT) images. METHODS. The imaging system is composed of a photographic slit lamp for biomicroscopic examination of the fundus, an OCT interferometer, an OCT beam delivery system designed for the mouse eye, and a mouse positioning stage. Image acquisition was controlled with software that displays the fundus and OCT images in real time, and allows the user to control the position of the OCT beam spot on the fundus image display. The anesthetized mouse was placed in a cylindrical holder on the positioning stage, and a single operator adjusted the position of mouse. RESULTS. Fundus images and OCT scans were successfully acquired in both eyes of 8 C57BL/6 mice. Once the animal is anesthetized and placed in the holder, a typical imaging experiment takes less than 2 minutes. The retinal vasculature, pigmentation, nerve fiber arrangement, and optic nerve head were clearly visible on the fundus images. The quality of the OCT images was sufficient to allow measurement of the total, inner, and outer retinal thicknesses and to visualize the optic nerve head excavation. CONCLUSIONS. The study demonstrates the feasibility of acquiring simultaneous fundus and OCT images of the mouse retina, by a single operator, in a manner suitable for routine evaluation of mouse models of retinal disease.

UR - http://www.scopus.com/inward/record.url?scp=34047256564&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34047256564&partnerID=8YFLogxK

U2 - 10.1167/iovs.06-0732

DO - 10.1167/iovs.06-0732

M3 - Article

C2 - 17325174

AN - SCOPUS:34047256564

VL - 48

SP - 1283

EP - 1289

JO - Investigative Ophthalmology and Visual Science

JF - Investigative Ophthalmology and Visual Science

SN - 0146-0404

IS - 3

ER -