Second degree His-Purkinje block during his bundle pacing

Agustin Castellanos, Federico Moleiro, Ruey J. Sung, Robert J Myerburg

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

This report presents, for the first time, clear evidence supporting the occurrence of Wenckebach and 2:1 H-V block during His bundle pacing. The simultaneous recording of various intracardiac electrograms, as well as the comparison of the effects produced by selective His bundle pacing and high right atrial pacing at the same rates, permitted the identification of conduction disturbances located distal to the paced His bundle site. This could be done although one criterion usually required to diagnose selective His bundle pacing (namely, stimulus-V intervals of constant duration) was not present.

Original languageEnglish
Pages (from-to)1110-1114
Number of pages5
JournalThe American journal of cardiology
Volume41
Issue number6
DOIs
StatePublished - May 22 1978

Fingerprint

Bundle of His
Cardiac Electrophysiologic Techniques

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Second degree His-Purkinje block during his bundle pacing. / Castellanos, Agustin; Moleiro, Federico; Sung, Ruey J.; Myerburg, Robert J.

In: The American journal of cardiology, Vol. 41, No. 6, 22.05.1978, p. 1110-1114.

Research output: Contribution to journalArticle

Castellanos, Agustin ; Moleiro, Federico ; Sung, Ruey J. ; Myerburg, Robert J. / Second degree His-Purkinje block during his bundle pacing. In: The American journal of cardiology. 1978 ; Vol. 41, No. 6. pp. 1110-1114.
@article{531375106c834f36848b335ca09a6062,
title = "Second degree His-Purkinje block during his bundle pacing",
abstract = "This report presents, for the first time, clear evidence supporting the occurrence of Wenckebach and 2:1 H-V block during His bundle pacing. The simultaneous recording of various intracardiac electrograms, as well as the comparison of the effects produced by selective His bundle pacing and high right atrial pacing at the same rates, permitted the identification of conduction disturbances located distal to the paced His bundle site. This could be done although one criterion usually required to diagnose selective His bundle pacing (namely, stimulus-V intervals of constant duration) was not present.",
author = "Agustin Castellanos and Federico Moleiro and Sung, {Ruey J.} and Myerburg, {Robert J}",
year = "1978",
month = "5",
day = "22",
doi = "10.1016/0002-9149(78)90865-2",
language = "English",
volume = "41",
pages = "1110--1114",
journal = "American Journal of Cardiology",
issn = "0002-9149",
publisher = "Elsevier Inc.",
number = "6",

}

TY - JOUR

T1 - Second degree His-Purkinje block during his bundle pacing

AU - Castellanos, Agustin

AU - Moleiro, Federico

AU - Sung, Ruey J.

AU - Myerburg, Robert J

PY - 1978/5/22

Y1 - 1978/5/22

N2 - This report presents, for the first time, clear evidence supporting the occurrence of Wenckebach and 2:1 H-V block during His bundle pacing. The simultaneous recording of various intracardiac electrograms, as well as the comparison of the effects produced by selective His bundle pacing and high right atrial pacing at the same rates, permitted the identification of conduction disturbances located distal to the paced His bundle site. This could be done although one criterion usually required to diagnose selective His bundle pacing (namely, stimulus-V intervals of constant duration) was not present.

AB - This report presents, for the first time, clear evidence supporting the occurrence of Wenckebach and 2:1 H-V block during His bundle pacing. The simultaneous recording of various intracardiac electrograms, as well as the comparison of the effects produced by selective His bundle pacing and high right atrial pacing at the same rates, permitted the identification of conduction disturbances located distal to the paced His bundle site. This could be done although one criterion usually required to diagnose selective His bundle pacing (namely, stimulus-V intervals of constant duration) was not present.

UR - http://www.scopus.com/inward/record.url?scp=0018091247&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018091247&partnerID=8YFLogxK

U2 - 10.1016/0002-9149(78)90865-2

DO - 10.1016/0002-9149(78)90865-2

M3 - Article

C2 - 665516

AN - SCOPUS:0018091247

VL - 41

SP - 1110

EP - 1114

JO - American Journal of Cardiology

JF - American Journal of Cardiology

SN - 0002-9149

IS - 6

ER -