Real-time projection MR angiography

Feasibility study

J. M. Serfaty, E. Atalar, J. Declerck, P. Karmakar, H. H. Quick, K. A. Shunk, A. W. Heldman, X. Yang

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.

Original languageEnglish
Pages (from-to)290-295
Number of pages6
JournalRadiology
Volume217
Issue number1
StatePublished - Dec 1 2000
Externally publishedYes

Fingerprint

Magnetic Resonance Angiography
Feasibility Studies
Magnetic Resonance Spectroscopy
Intra-Arterial Injections
Gadolinium DTPA
Fluoroscopy
Aorta
Canidae
Coronary Vessels
Perfusion
Rabbits

Keywords

  • Angiography, contrast media
  • Gadolinium
  • Magnetic resonance (MR), contrast enhancement
  • Magnetic resonance (MR), guidance
  • Magnetic resonance (MR), vascular studies

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Serfaty, J. M., Atalar, E., Declerck, J., Karmakar, P., Quick, H. H., Shunk, K. A., ... Yang, X. (2000). Real-time projection MR angiography: Feasibility study. Radiology, 217(1), 290-295.

Real-time projection MR angiography : Feasibility study. / Serfaty, J. M.; Atalar, E.; Declerck, J.; Karmakar, P.; Quick, H. H.; Shunk, K. A.; Heldman, A. W.; Yang, X.

In: Radiology, Vol. 217, No. 1, 01.12.2000, p. 290-295.

Research output: Contribution to journalArticle

Serfaty, JM, Atalar, E, Declerck, J, Karmakar, P, Quick, HH, Shunk, KA, Heldman, AW & Yang, X 2000, 'Real-time projection MR angiography: Feasibility study', Radiology, vol. 217, no. 1, pp. 290-295.
Serfaty JM, Atalar E, Declerck J, Karmakar P, Quick HH, Shunk KA et al. Real-time projection MR angiography: Feasibility study. Radiology. 2000 Dec 1;217(1):290-295.
Serfaty, J. M. ; Atalar, E. ; Declerck, J. ; Karmakar, P. ; Quick, H. H. ; Shunk, K. A. ; Heldman, A. W. ; Yang, X. / Real-time projection MR angiography : Feasibility study. In: Radiology. 2000 ; Vol. 217, No. 1. pp. 290-295.
@article{ed64bdcf46d54f53888fc7d401ecead4,
title = "Real-time projection MR angiography: Feasibility study",
abstract = "Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.",
keywords = "Angiography, contrast media, Gadolinium, Magnetic resonance (MR), contrast enhancement, Magnetic resonance (MR), guidance, Magnetic resonance (MR), vascular studies",
author = "Serfaty, {J. M.} and E. Atalar and J. Declerck and P. Karmakar and Quick, {H. H.} and Shunk, {K. A.} and Heldman, {A. W.} and X. Yang",
year = "2000",
month = "12",
day = "1",
language = "English",
volume = "217",
pages = "290--295",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "1",

}

TY - JOUR

T1 - Real-time projection MR angiography

T2 - Feasibility study

AU - Serfaty, J. M.

AU - Atalar, E.

AU - Declerck, J.

AU - Karmakar, P.

AU - Quick, H. H.

AU - Shunk, K. A.

AU - Heldman, A. W.

AU - Yang, X.

PY - 2000/12/1

Y1 - 2000/12/1

N2 - Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.

AB - Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.

KW - Angiography, contrast media

KW - Gadolinium

KW - Magnetic resonance (MR), contrast enhancement

KW - Magnetic resonance (MR), guidance

KW - Magnetic resonance (MR), vascular studies

UR - http://www.scopus.com/inward/record.url?scp=0034543128&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034543128&partnerID=8YFLogxK

M3 - Article

VL - 217

SP - 290

EP - 295

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 1

ER -