T1 - Prospective multicenter clinical evaluation of AMPLICOR and COBAS AMPLICOR hepatitis C virus tests
AU - Nolte, F. S.
AU - Fried, M. W.
AU - Shiffman, M. L.
AU - Ferreira-Gonzalez, A.
AU - Garrett, C. T.
AU - Schiff, E. R.
AU - Polyak, S. J.
AU - Gretch, D. R.
N1 - Copyright:
Copyright 2007 Elsevier B.V., All rights reserved.
PY - 2001
Y1 - 2001
N2 - We conducted a multicenter clinical evaluation of the second versions of the manual AMPLICOR and the semiautomated COBAS AMPLICOR tests for hepatitis C virus (HCV) RNA (Roche Molecular Systems, Inc., Pleasanton, Calif.). The performance characteristics of these HCV RNA tests for diagnosis of active viral infection were determined by comparison to anti-HCV serological test results, alanine aminotransferase levels, and liver biopsy histology results. A total of 878 patients with clinical or biochemical evidence of liver disease were enrolled at four hepatology clinics. A total of 1,089 specimens (901 serum and 188 plasma) were tested with the AMPLICOR test. Sensitivity compared to serology was 93.1% for serum and 90.6% for plasma. The specificity was 97% for serum and 93.1% for plasma. A total of 1,084 specimens (896 serum and 188 plasma) were tested with the COBAS test. Sensitivities for serum and plasma were the same as with the AMPLICOR test. The specificity was 97.8% for serum and 96.6% for plasma. Of the 69 specimens with false-positive and false-negative AMPLICOR test results relative to those of serology, alternative primer set (APS) reverse transcription (RT)-PCR analysis showed that the AMPLICOR test provided the correct result relative to the specimens containing HCV RNA in 64 (92.7%) specimens. Similarly, 66 of 67 (98.5%) false-positive and false-negative COBAS test results were determined to be correct by APS RT-PCR analysis. There were no substantive differences in clinical performances between study sites, patient groups, specimen types, storage conditions (-20 to -80°C versus 2 to 8°C), or anticoagulants (EDTA versus acid citrate dextrose) for either test. Both tests showed >99% reproducibility within runs, within sites, and overall. We conclude that these tests can reliably detect the presence of HCV RNA, as evidence of active infection, in patients with clinical or biochemical evidence of liver disease.
AB - We conducted a multicenter clinical evaluation of the second versions of the manual AMPLICOR and the semiautomated COBAS AMPLICOR tests for hepatitis C virus (HCV) RNA (Roche Molecular Systems, Inc., Pleasanton, Calif.). The performance characteristics of these HCV RNA tests for diagnosis of active viral infection were determined by comparison to anti-HCV serological test results, alanine aminotransferase levels, and liver biopsy histology results. A total of 878 patients with clinical or biochemical evidence of liver disease were enrolled at four hepatology clinics. A total of 1,089 specimens (901 serum and 188 plasma) were tested with the AMPLICOR test. Sensitivity compared to serology was 93.1% for serum and 90.6% for plasma. The specificity was 97% for serum and 93.1% for plasma. A total of 1,084 specimens (896 serum and 188 plasma) were tested with the COBAS test. Sensitivities for serum and plasma were the same as with the AMPLICOR test. The specificity was 97.8% for serum and 96.6% for plasma. Of the 69 specimens with false-positive and false-negative AMPLICOR test results relative to those of serology, alternative primer set (APS) reverse transcription (RT)-PCR analysis showed that the AMPLICOR test provided the correct result relative to the specimens containing HCV RNA in 64 (92.7%) specimens. Similarly, 66 of 67 (98.5%) false-positive and false-negative COBAS test results were determined to be correct by APS RT-PCR analysis. There were no substantive differences in clinical performances between study sites, patient groups, specimen types, storage conditions (-20 to -80°C versus 2 to 8°C), or anticoagulants (EDTA versus acid citrate dextrose) for either test. Both tests showed >99% reproducibility within runs, within sites, and overall. We conclude that these tests can reliably detect the presence of HCV RNA, as evidence of active infection, in patients with clinical or biochemical evidence of liver disease.
UR - http://www.scopus.com/inward/record.url?scp=0034764239&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034764239&partnerID=8YFLogxK
U2 - 10.1128/JCM.39.11.4005-4012.2001
DO - 10.1128/JCM.39.11.4005-4012.2001
M3 - Article
C2 - 11682522
AN - SCOPUS:0034764239
VL - 39
SP - 4005
EP - 4012
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
SN - 0095-1137
IS - 11
ER -