TY - JOUR
T1 - Prediction of corneal graft rejection using central endothelium/Descemet’s membrane complex thickness in high-risk corneal transplants
AU - Eleiwa, Taher
AU - Elsawy, Amr
AU - Ozcan, Eyup
AU - Chase, Collin
AU - Feuer, William
AU - Yoo, Sonia H.
AU - Perez Quinones, Victor L
AU - Abou Shousha, Mohamed F.
N1 - Funding Information:
This study was supported by a NEI K23 award (K23EY026118), NEI core center grant to the University of Miami (P30 EY014801), and Research to Prevent Blindness (RPB). The funding organization had no role in the design or conduct of this research.
Publisher Copyright:
© 2021, The Author(s).
PY - 2021/12
Y1 - 2021/12
N2 - To determine whether measurements of Endothelium/Descemet complex thickness (En/DMT) are of predictive value for corneal graft rejection after high-risk corneal transplantation, we conducted this prospective, single-center, observational case series including sixty eyes (60 patients) at high risk for corneal graft rejection (GR) because of previous immunologic graft failure or having at least two quadrants of stromal vascularization. Patients underwent corneal transplant. At 1st, 3rd, 6th, 9th, and 12th postoperative month, HD-OCT imaging of the cornea was performed, and the corneal status was determined clinically at each visit by a masked cornea specialist. Custom-built segmentation tomography algorithm was used to measure the central En/DMT. Relationships between baseline factors and En/DMT were explored. Time dependent covariate Cox survival regression was used to assess the effect of post-operative En/DMT changes during follow up. A longitudinal repeated measures model was used to assess the relationship between En/DMT and graft status. Outcome measures included graft rejection, central Endothelium/Descemet’s complex thickness, and central corneal thickness (CCT). In patients with GR (35%), the central En/DMT increased significantly 5.3 months (95% CI: 2, 11) prior to the clinical diagnosis of GR, while it remained stable in patients without GR. During the 1-year follow up, the rejected grafts have higher mean pre-rejection En/DMTs (p = 0.01), compared to CCTs (p = 0.7). For En/DMT ≥ 18 µm cut-off (at any pre-rejection visit), the Cox proportional hazard ratio was 6.89 (95% CI: 2.03, 23.4; p = 0.002), and it increased to 9.91 (95% CI: 3.32, 29.6; p < 0.001) with a ≥ 19 µm cut-off. In high-risk corneal transplants, the increase in En/DMT allowed predicting rejection prior to the clinical diagnosis.
AB - To determine whether measurements of Endothelium/Descemet complex thickness (En/DMT) are of predictive value for corneal graft rejection after high-risk corneal transplantation, we conducted this prospective, single-center, observational case series including sixty eyes (60 patients) at high risk for corneal graft rejection (GR) because of previous immunologic graft failure or having at least two quadrants of stromal vascularization. Patients underwent corneal transplant. At 1st, 3rd, 6th, 9th, and 12th postoperative month, HD-OCT imaging of the cornea was performed, and the corneal status was determined clinically at each visit by a masked cornea specialist. Custom-built segmentation tomography algorithm was used to measure the central En/DMT. Relationships between baseline factors and En/DMT were explored. Time dependent covariate Cox survival regression was used to assess the effect of post-operative En/DMT changes during follow up. A longitudinal repeated measures model was used to assess the relationship between En/DMT and graft status. Outcome measures included graft rejection, central Endothelium/Descemet’s complex thickness, and central corneal thickness (CCT). In patients with GR (35%), the central En/DMT increased significantly 5.3 months (95% CI: 2, 11) prior to the clinical diagnosis of GR, while it remained stable in patients without GR. During the 1-year follow up, the rejected grafts have higher mean pre-rejection En/DMTs (p = 0.01), compared to CCTs (p = 0.7). For En/DMT ≥ 18 µm cut-off (at any pre-rejection visit), the Cox proportional hazard ratio was 6.89 (95% CI: 2.03, 23.4; p = 0.002), and it increased to 9.91 (95% CI: 3.32, 29.6; p < 0.001) with a ≥ 19 µm cut-off. In high-risk corneal transplants, the increase in En/DMT allowed predicting rejection prior to the clinical diagnosis.
UR - http://www.scopus.com/inward/record.url?scp=85110721899&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85110721899&partnerID=8YFLogxK
U2 - 10.1038/s41598-021-93892-4
DO - 10.1038/s41598-021-93892-4
M3 - Article
C2 - 34267265
AN - SCOPUS:85110721899
VL - 11
JO - Scientific Reports
JF - Scientific Reports
SN - 2045-2322
IS - 1
M1 - 14542
ER -