Phased-array combination for MR spectroscopic imaging using a water reference

Abas Abdoli, Andrew A Maudsley

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Purpose: To evaluate methods for multichannel combination of three-dimensional MR spectroscopic imaging (MRSI) data with a focus on using information from a water-reference spectroscopic image. Methods: Volumetric MRSI data were acquired for a phantom and for human brain using 8- and 32-channel detection. Acquisition included a water-reference dataset that was used to determine the weights for several multichannel combination methods. Results were compared using the signal-to-noise ratio (SNR) of the N-acetylaspartate resonance. Results: Performance of all methods was very similar for the phantom study, with the whitened singular value decomposition (WSVD) and signal magnitude (S) weighting combination having a small advantage. For in vivo studies, the S weighting, SNR weighting and signal to noise squared (S/N2) weighting were the three best methods and performed similarly. Example spectra and SNR maps indicated that the SVD and WSVD methods tend to fail for voxels at the outer edges of the brain that include strong lipid signal contributions. Conclusion: For data combination of MRSI data using water-reference information, the S/N2 weighting, SNR and S weighting were the best methods in terms of spectral quality SNR. These methods are also computationally efficient and easy to implement. Magn Reson Med 76:733–741, 2016.

Original languageEnglish (US)
Pages (from-to)733-741
Number of pages9
JournalMagnetic Resonance in Medicine
Volume76
Issue number3
DOIs
StatePublished - 2016

Fingerprint

Signal-To-Noise Ratio
Water
Brain
Noise
Lipids
Weights and Measures

Keywords

  • MRSI
  • multichannel detection
  • phased-array combination
  • SNR
  • water-reference

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Phased-array combination for MR spectroscopic imaging using a water reference. / Abdoli, Abas; Maudsley, Andrew A.

In: Magnetic Resonance in Medicine, Vol. 76, No. 3, 2016, p. 733-741.

Research output: Contribution to journalArticle

@article{d1da8ed1a9254ee09af8a3d6f6ed5ea5,
title = "Phased-array combination for MR spectroscopic imaging using a water reference",
abstract = "Purpose: To evaluate methods for multichannel combination of three-dimensional MR spectroscopic imaging (MRSI) data with a focus on using information from a water-reference spectroscopic image. Methods: Volumetric MRSI data were acquired for a phantom and for human brain using 8- and 32-channel detection. Acquisition included a water-reference dataset that was used to determine the weights for several multichannel combination methods. Results were compared using the signal-to-noise ratio (SNR) of the N-acetylaspartate resonance. Results: Performance of all methods was very similar for the phantom study, with the whitened singular value decomposition (WSVD) and signal magnitude (S) weighting combination having a small advantage. For in vivo studies, the S weighting, SNR weighting and signal to noise squared (S/N2) weighting were the three best methods and performed similarly. Example spectra and SNR maps indicated that the SVD and WSVD methods tend to fail for voxels at the outer edges of the brain that include strong lipid signal contributions. Conclusion: For data combination of MRSI data using water-reference information, the S/N2 weighting, SNR and S weighting were the best methods in terms of spectral quality SNR. These methods are also computationally efficient and easy to implement. Magn Reson Med 76:733–741, 2016.",
keywords = "MRSI, multichannel detection, phased-array combination, SNR, water-reference",
author = "Abas Abdoli and Maudsley, {Andrew A}",
year = "2016",
doi = "10.1002/mrm.25992",
language = "English (US)",
volume = "76",
pages = "733--741",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Phased-array combination for MR spectroscopic imaging using a water reference

AU - Abdoli, Abas

AU - Maudsley, Andrew A

PY - 2016

Y1 - 2016

N2 - Purpose: To evaluate methods for multichannel combination of three-dimensional MR spectroscopic imaging (MRSI) data with a focus on using information from a water-reference spectroscopic image. Methods: Volumetric MRSI data were acquired for a phantom and for human brain using 8- and 32-channel detection. Acquisition included a water-reference dataset that was used to determine the weights for several multichannel combination methods. Results were compared using the signal-to-noise ratio (SNR) of the N-acetylaspartate resonance. Results: Performance of all methods was very similar for the phantom study, with the whitened singular value decomposition (WSVD) and signal magnitude (S) weighting combination having a small advantage. For in vivo studies, the S weighting, SNR weighting and signal to noise squared (S/N2) weighting were the three best methods and performed similarly. Example spectra and SNR maps indicated that the SVD and WSVD methods tend to fail for voxels at the outer edges of the brain that include strong lipid signal contributions. Conclusion: For data combination of MRSI data using water-reference information, the S/N2 weighting, SNR and S weighting were the best methods in terms of spectral quality SNR. These methods are also computationally efficient and easy to implement. Magn Reson Med 76:733–741, 2016.

AB - Purpose: To evaluate methods for multichannel combination of three-dimensional MR spectroscopic imaging (MRSI) data with a focus on using information from a water-reference spectroscopic image. Methods: Volumetric MRSI data were acquired for a phantom and for human brain using 8- and 32-channel detection. Acquisition included a water-reference dataset that was used to determine the weights for several multichannel combination methods. Results were compared using the signal-to-noise ratio (SNR) of the N-acetylaspartate resonance. Results: Performance of all methods was very similar for the phantom study, with the whitened singular value decomposition (WSVD) and signal magnitude (S) weighting combination having a small advantage. For in vivo studies, the S weighting, SNR weighting and signal to noise squared (S/N2) weighting were the three best methods and performed similarly. Example spectra and SNR maps indicated that the SVD and WSVD methods tend to fail for voxels at the outer edges of the brain that include strong lipid signal contributions. Conclusion: For data combination of MRSI data using water-reference information, the S/N2 weighting, SNR and S weighting were the best methods in terms of spectral quality SNR. These methods are also computationally efficient and easy to implement. Magn Reson Med 76:733–741, 2016.

KW - MRSI

KW - multichannel detection

KW - phased-array combination

KW - SNR

KW - water-reference

UR - http://www.scopus.com/inward/record.url?scp=84982281244&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84982281244&partnerID=8YFLogxK

U2 - 10.1002/mrm.25992

DO - 10.1002/mrm.25992

M3 - Article

VL - 76

SP - 733

EP - 741

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -