Purpose: X-ray CT faces challenges in differentiating tumors from surrounding healthy tissues. A bioluminescence tomography (BLT) system which can directly reconstruct the internal luminescent tumors, was developed and integrated with CT system to accurately guide radiation dose delivery. Methods: The BLT system, employing a lens-coupled CCD camera, was physically registered with an onboard cone beam CT system in an image-guided small animal arc radiation treatment system (iSMAART). The onboard CT provides animal anatomy and accurate surface contour used to construct the three-dimensional mesh for the BLT reconstruction. Bioluminescence projections were captured from multiple angles, once every 90 rotation. The BLT reconstruction was performed on an orthotopic prostate tumor model to evaluate its robustness and accuracy in locating and delineating bioluminescent tumors. The location and volume of the tumor identified from iodinated contrast CT was used to validate the BLT performance. Phantom experiment was also conducted to confirm the precision of BLT-guided radiation. Results: The BLT was able to accurately locate the bioluminescent tumors with < 0.5 mm error. The tumor volume in BLT was significantly correlated with that in the iodinated contrast CT (R2 = 0.81, P < 0.001). Phantom experiments further validated that BLT can be used to guide radiation with submillimeter accuracy. Conclusion: Together with CT, BLT can provide precision radiation guidance and robust tumor volume assessment in small animal cancer research.

Original languageEnglish (US)
Pages (from-to)4786-4794
Number of pages9
JournalMedical Physics
Volume44
Issue number9
DOIs
StatePublished - Sep 1 2017

Fingerprint

Molecular Imaging
Optical Imaging
Radiotherapy
Tomography
X-Rays
Radiation
Tumor Burden
Neoplasms
Cone-Beam Computed Tomography
X Ray Computed Tomography
Lenses
Prostate
Anatomy

Keywords

  • bioluminescence tomography
  • cone-beam computed tomography
  • in vivo mice experiments
  • orthotopic prostate tumor
  • radiation guidance

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Optical molecular imaging-guided radiation therapy part 1 : Integrated x-ray and bioluminescence tomography: Integrated. / Shi, Junwei; Udayakumar, Thirupandiyur; Wang, Zhiqun; Dogan, Nesrin; Pollack, Alan; Yang, Yidong.

In: Medical Physics, Vol. 44, No. 9, 01.09.2017, p. 4786-4794.

Research output: Contribution to journalArticle

@article{5022016bd15a4859a6ba9b60eaf261d3,
title = "Optical molecular imaging-guided radiation therapy part 1: Integrated x-ray and bioluminescence tomography: Integrated",
abstract = "Purpose: X-ray CT faces challenges in differentiating tumors from surrounding healthy tissues. A bioluminescence tomography (BLT) system which can directly reconstruct the internal luminescent tumors, was developed and integrated with CT system to accurately guide radiation dose delivery. Methods: The BLT system, employing a lens-coupled CCD camera, was physically registered with an onboard cone beam CT system in an image-guided small animal arc radiation treatment system (iSMAART). The onboard CT provides animal anatomy and accurate surface contour used to construct the three-dimensional mesh for the BLT reconstruction. Bioluminescence projections were captured from multiple angles, once every 90 rotation. The BLT reconstruction was performed on an orthotopic prostate tumor model to evaluate its robustness and accuracy in locating and delineating bioluminescent tumors. The location and volume of the tumor identified from iodinated contrast CT was used to validate the BLT performance. Phantom experiment was also conducted to confirm the precision of BLT-guided radiation. Results: The BLT was able to accurately locate the bioluminescent tumors with < 0.5 mm error. The tumor volume in BLT was significantly correlated with that in the iodinated contrast CT (R2 = 0.81, P < 0.001). Phantom experiments further validated that BLT can be used to guide radiation with submillimeter accuracy. Conclusion: Together with CT, BLT can provide precision radiation guidance and robust tumor volume assessment in small animal cancer research.",
keywords = "bioluminescence tomography, cone-beam computed tomography, in vivo mice experiments, orthotopic prostate tumor, radiation guidance",
author = "Junwei Shi and Thirupandiyur Udayakumar and Zhiqun Wang and Nesrin Dogan and Alan Pollack and Yidong Yang",
year = "2017",
month = "9",
day = "1",
doi = "10.1002/mp.12415",
language = "English (US)",
volume = "44",
pages = "4786--4794",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "9",

}

TY - JOUR

T1 - Optical molecular imaging-guided radiation therapy part 1

T2 - Integrated x-ray and bioluminescence tomography: Integrated

AU - Shi, Junwei

AU - Udayakumar, Thirupandiyur

AU - Wang, Zhiqun

AU - Dogan, Nesrin

AU - Pollack, Alan

AU - Yang, Yidong

PY - 2017/9/1

Y1 - 2017/9/1

N2 - Purpose: X-ray CT faces challenges in differentiating tumors from surrounding healthy tissues. A bioluminescence tomography (BLT) system which can directly reconstruct the internal luminescent tumors, was developed and integrated with CT system to accurately guide radiation dose delivery. Methods: The BLT system, employing a lens-coupled CCD camera, was physically registered with an onboard cone beam CT system in an image-guided small animal arc radiation treatment system (iSMAART). The onboard CT provides animal anatomy and accurate surface contour used to construct the three-dimensional mesh for the BLT reconstruction. Bioluminescence projections were captured from multiple angles, once every 90 rotation. The BLT reconstruction was performed on an orthotopic prostate tumor model to evaluate its robustness and accuracy in locating and delineating bioluminescent tumors. The location and volume of the tumor identified from iodinated contrast CT was used to validate the BLT performance. Phantom experiment was also conducted to confirm the precision of BLT-guided radiation. Results: The BLT was able to accurately locate the bioluminescent tumors with < 0.5 mm error. The tumor volume in BLT was significantly correlated with that in the iodinated contrast CT (R2 = 0.81, P < 0.001). Phantom experiments further validated that BLT can be used to guide radiation with submillimeter accuracy. Conclusion: Together with CT, BLT can provide precision radiation guidance and robust tumor volume assessment in small animal cancer research.

AB - Purpose: X-ray CT faces challenges in differentiating tumors from surrounding healthy tissues. A bioluminescence tomography (BLT) system which can directly reconstruct the internal luminescent tumors, was developed and integrated with CT system to accurately guide radiation dose delivery. Methods: The BLT system, employing a lens-coupled CCD camera, was physically registered with an onboard cone beam CT system in an image-guided small animal arc radiation treatment system (iSMAART). The onboard CT provides animal anatomy and accurate surface contour used to construct the three-dimensional mesh for the BLT reconstruction. Bioluminescence projections were captured from multiple angles, once every 90 rotation. The BLT reconstruction was performed on an orthotopic prostate tumor model to evaluate its robustness and accuracy in locating and delineating bioluminescent tumors. The location and volume of the tumor identified from iodinated contrast CT was used to validate the BLT performance. Phantom experiment was also conducted to confirm the precision of BLT-guided radiation. Results: The BLT was able to accurately locate the bioluminescent tumors with < 0.5 mm error. The tumor volume in BLT was significantly correlated with that in the iodinated contrast CT (R2 = 0.81, P < 0.001). Phantom experiments further validated that BLT can be used to guide radiation with submillimeter accuracy. Conclusion: Together with CT, BLT can provide precision radiation guidance and robust tumor volume assessment in small animal cancer research.

KW - bioluminescence tomography

KW - cone-beam computed tomography

KW - in vivo mice experiments

KW - orthotopic prostate tumor

KW - radiation guidance

UR - http://www.scopus.com/inward/record.url?scp=85029233317&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85029233317&partnerID=8YFLogxK

U2 - 10.1002/mp.12415

DO - 10.1002/mp.12415

M3 - Article

C2 - 28627007

AN - SCOPUS:85029233317

VL - 44

SP - 4786

EP - 4794

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 9

ER -