T1 - Neutron dose in and out of 18 MV photon fields
AU - Ezzati, A. O.
AU - Studenski, M. T.
N1 - Funding Information:
This work was supported by the University of Tabriz (Grant no. 4428).
Publisher Copyright:
© 2017 Elsevier Ltd
PY - 2017/4/1
Y1 - 2017/4/1
N2 - In radiation therapy, neutron contamination is an undesirable side effect of using high energy photons to treat patients. Neutron contamination requires adjustments to the shielding requirements of the linear accelerator vault and contributes to the risk of secondary malignancies in patients by delivering dose outside of the primary treatment field. Using MCNPX, an established Monte Carlo code, manufacturer blueprints, and the most up to date ICRP neutron dose conversion factors, the neutron spectra, neutron/photon dose ratio, and the neutron capture gamma ray dose were calculated at different depths and off axis distances in a tissue equivalent phantom. Results demonstrated that the neutron spectra and dose are dependent on field size, depth in the phantom, and off-axis distance. Simulations showed that because of the low neutron absorption cross section of the linear accelerator head materials, the contribution to overall patient dose from neutrons can be up to 1000 times the photon dose out of the treatment field and is also dependent on field size and depth. Beyond 45 cm off-axis, the dependence of the neutron dose on field size is minimal. Neutron capture gamma ray dose is also field size dependent and is at a maximum at a depth of about 7 cm. It is important to remember that when treating with high energy photons, the dose from contamination neutrons must be considered as it is much greater than the photon dose.
AB - In radiation therapy, neutron contamination is an undesirable side effect of using high energy photons to treat patients. Neutron contamination requires adjustments to the shielding requirements of the linear accelerator vault and contributes to the risk of secondary malignancies in patients by delivering dose outside of the primary treatment field. Using MCNPX, an established Monte Carlo code, manufacturer blueprints, and the most up to date ICRP neutron dose conversion factors, the neutron spectra, neutron/photon dose ratio, and the neutron capture gamma ray dose were calculated at different depths and off axis distances in a tissue equivalent phantom. Results demonstrated that the neutron spectra and dose are dependent on field size, depth in the phantom, and off-axis distance. Simulations showed that because of the low neutron absorption cross section of the linear accelerator head materials, the contribution to overall patient dose from neutrons can be up to 1000 times the photon dose out of the treatment field and is also dependent on field size and depth. Beyond 45 cm off-axis, the dependence of the neutron dose on field size is minimal. Neutron capture gamma ray dose is also field size dependent and is at a maximum at a depth of about 7 cm. It is important to remember that when treating with high energy photons, the dose from contamination neutrons must be considered as it is much greater than the photon dose.
KW - High energy photons
KW - Monte Carlo
KW - Neutron capture gamma
KW - Neutron contamination dose
KW - Out-of-field dose
UR - http://www.scopus.com/inward/record.url?scp=85012305636&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85012305636&partnerID=8YFLogxK
U2 - 10.1016/j.apradiso.2017.01.046
DO - 10.1016/j.apradiso.2017.01.046
M3 - Article
C2 - 28167445
AN - SCOPUS:85012305636
VL - 122
SP - 186
EP - 192
JO - Applied Radiation and Isotopes
JF - Applied Radiation and Isotopes
SN - 0969-8043
ER -