Abstract

Background: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously analyze the electronic nuclear volume (ENV) and DNA content of cells. This study describes the schematics, resolution, reproducibility, and sensitivity of biological standards analyzed on this unit. Methods: Calibrated beads and biological standards (lymphocytes, trout erythrocytes [TRBC], calf thymocytes, and tumor cells) were analyzed for ENV versus DNA content. Parallel data (forward scatter versus DNA) from a conventional flow cytometer were obtained. Results: ENV linearity studies yielded an R value of 0.999. TRBC had a coefficient of variation (CV) of 1.18 ± 0.13. DNA indexes as low as 1.02 were detectable. DNA content of lymphocytes from 42 females was 1.9% greater than that for 60 males, with a noninstrumental variability in total DNA content of 0.5%. The ENV/DNA ratio was constant in 15 normal human tissue samples, but differed in the four animal species tested. The ENV/DNA ratio for a hypodiploid breast carcinoma was 2.3 times greater than that for normal breast tissue. Conclusions: The high-resolution ENV versus DNA analyses are highly reliable, sensitive, and can be used for the detection of near-diploid tumor cells that are difficult to identify with conventional cytometers. ENV/DNA ratio may be a useful parameter for detection of aneuploid populations. Published 2001 Wiley-Liss, Inc.

Original languageEnglish
Pages (from-to)2-11
Number of pages10
JournalCytometry
Volume43
Issue number1
DOIs
StatePublished - Jan 1 2001
Externally publishedYes

Fingerprint

United States National Aeronautics and Space Administration
Flow Cytometry
DNA
Lymphocytes
Trout
Aneuploidy
Thymocytes
Diploidy
Neoplasms
Breast
Erythrocytes

Keywords

  • DNA
  • Electronic nuclear volume
  • Flow cytometry
  • Forward scatter
  • Inflight cytometer
  • NASA/American Cancer Society
  • Nuclear packing efficiency

ASJC Scopus subject areas

  • Hematology
  • Cell Biology
  • Pathology and Forensic Medicine
  • Biophysics
  • Endocrinology

Cite this

NASA/American Cancer Society high-resolution flow cytometry project-I. / Thomas, Richard A.; Krishan, Awtar; Robinson, David M.; Sams, Clarence; Costa, Francesco.

In: Cytometry, Vol. 43, No. 1, 01.01.2001, p. 2-11.

Research output: Contribution to journalArticle

Thomas, Richard A. ; Krishan, Awtar ; Robinson, David M. ; Sams, Clarence ; Costa, Francesco. / NASA/American Cancer Society high-resolution flow cytometry project-I. In: Cytometry. 2001 ; Vol. 43, No. 1. pp. 2-11.
@article{c1a8b30aedb24cd987143e3685f4f2c4,
title = "NASA/American Cancer Society high-resolution flow cytometry project-I",
abstract = "Background: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously analyze the electronic nuclear volume (ENV) and DNA content of cells. This study describes the schematics, resolution, reproducibility, and sensitivity of biological standards analyzed on this unit. Methods: Calibrated beads and biological standards (lymphocytes, trout erythrocytes [TRBC], calf thymocytes, and tumor cells) were analyzed for ENV versus DNA content. Parallel data (forward scatter versus DNA) from a conventional flow cytometer were obtained. Results: ENV linearity studies yielded an R value of 0.999. TRBC had a coefficient of variation (CV) of 1.18 ± 0.13. DNA indexes as low as 1.02 were detectable. DNA content of lymphocytes from 42 females was 1.9{\%} greater than that for 60 males, with a noninstrumental variability in total DNA content of 0.5{\%}. The ENV/DNA ratio was constant in 15 normal human tissue samples, but differed in the four animal species tested. The ENV/DNA ratio for a hypodiploid breast carcinoma was 2.3 times greater than that for normal breast tissue. Conclusions: The high-resolution ENV versus DNA analyses are highly reliable, sensitive, and can be used for the detection of near-diploid tumor cells that are difficult to identify with conventional cytometers. ENV/DNA ratio may be a useful parameter for detection of aneuploid populations. Published 2001 Wiley-Liss, Inc.",
keywords = "DNA, Electronic nuclear volume, Flow cytometry, Forward scatter, Inflight cytometer, NASA/American Cancer Society, Nuclear packing efficiency",
author = "Thomas, {Richard A.} and Awtar Krishan and Robinson, {David M.} and Clarence Sams and Francesco Costa",
year = "2001",
month = "1",
day = "1",
doi = "10.1002/1097-0320(20010101)43:1<2::AID-CYTO1012>3.0.CO;2-J",
language = "English",
volume = "43",
pages = "2--11",
journal = "Cytometry Part B - Clinical Cytometry",
issn = "1552-4949",
publisher = "Wiley-Liss Inc.",
number = "1",

}

TY - JOUR

T1 - NASA/American Cancer Society high-resolution flow cytometry project-I

AU - Thomas, Richard A.

AU - Krishan, Awtar

AU - Robinson, David M.

AU - Sams, Clarence

AU - Costa, Francesco

PY - 2001/1/1

Y1 - 2001/1/1

N2 - Background: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously analyze the electronic nuclear volume (ENV) and DNA content of cells. This study describes the schematics, resolution, reproducibility, and sensitivity of biological standards analyzed on this unit. Methods: Calibrated beads and biological standards (lymphocytes, trout erythrocytes [TRBC], calf thymocytes, and tumor cells) were analyzed for ENV versus DNA content. Parallel data (forward scatter versus DNA) from a conventional flow cytometer were obtained. Results: ENV linearity studies yielded an R value of 0.999. TRBC had a coefficient of variation (CV) of 1.18 ± 0.13. DNA indexes as low as 1.02 were detectable. DNA content of lymphocytes from 42 females was 1.9% greater than that for 60 males, with a noninstrumental variability in total DNA content of 0.5%. The ENV/DNA ratio was constant in 15 normal human tissue samples, but differed in the four animal species tested. The ENV/DNA ratio for a hypodiploid breast carcinoma was 2.3 times greater than that for normal breast tissue. Conclusions: The high-resolution ENV versus DNA analyses are highly reliable, sensitive, and can be used for the detection of near-diploid tumor cells that are difficult to identify with conventional cytometers. ENV/DNA ratio may be a useful parameter for detection of aneuploid populations. Published 2001 Wiley-Liss, Inc.

AB - Background: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously analyze the electronic nuclear volume (ENV) and DNA content of cells. This study describes the schematics, resolution, reproducibility, and sensitivity of biological standards analyzed on this unit. Methods: Calibrated beads and biological standards (lymphocytes, trout erythrocytes [TRBC], calf thymocytes, and tumor cells) were analyzed for ENV versus DNA content. Parallel data (forward scatter versus DNA) from a conventional flow cytometer were obtained. Results: ENV linearity studies yielded an R value of 0.999. TRBC had a coefficient of variation (CV) of 1.18 ± 0.13. DNA indexes as low as 1.02 were detectable. DNA content of lymphocytes from 42 females was 1.9% greater than that for 60 males, with a noninstrumental variability in total DNA content of 0.5%. The ENV/DNA ratio was constant in 15 normal human tissue samples, but differed in the four animal species tested. The ENV/DNA ratio for a hypodiploid breast carcinoma was 2.3 times greater than that for normal breast tissue. Conclusions: The high-resolution ENV versus DNA analyses are highly reliable, sensitive, and can be used for the detection of near-diploid tumor cells that are difficult to identify with conventional cytometers. ENV/DNA ratio may be a useful parameter for detection of aneuploid populations. Published 2001 Wiley-Liss, Inc.

KW - DNA

KW - Electronic nuclear volume

KW - Flow cytometry

KW - Forward scatter

KW - Inflight cytometer

KW - NASA/American Cancer Society

KW - Nuclear packing efficiency

UR - http://www.scopus.com/inward/record.url?scp=0035170310&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035170310&partnerID=8YFLogxK

U2 - 10.1002/1097-0320(20010101)43:1<2::AID-CYTO1012>3.0.CO;2-J

DO - 10.1002/1097-0320(20010101)43:1<2::AID-CYTO1012>3.0.CO;2-J

M3 - Article

C2 - 11122478

AN - SCOPUS:0035170310

VL - 43

SP - 2

EP - 11

JO - Cytometry Part B - Clinical Cytometry

JF - Cytometry Part B - Clinical Cytometry

SN - 1552-4949

IS - 1

ER -