Motion artifact on high-resolution CT images of pediatric patients: Comparison of volumetric and axial CT methods

Maria D Almeida Bastos, Edward Y. Lee, Keith J. Strauss, David Zurakowski, Donald A. Tracy, Phillip M. Boiselle

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

OBJECTIVE. The purpose of this study was to address the controversy whether the quality of volumetric high-resolution CT (HRCT) images is as good as that of axial nonvolumetric HRCT images by assessing the degree of motion artifact on images acquired with the two methods at MDCT of pediatric patients with known or suspected lung disease. MATERIALS AND METHODS. A search of the hospital information system was conducted to identify the cases of pediatric patients with clinically suspected or known interstitial lung disease who underwent 16-MDCT of the chest with both volumetric and axial HRCT acquisitions (both 1.25-mm slice thickness) from March 2005 to July 2008. Two pediatric radiologists reviewed the images for the presence of motion artifacts at three anatomic levels (upper, middle, and lower lung zones). Motion artifacts were given numerical grades representing no artifact to severe artifact, and the paired Student's t test was used to compare the scores for the two acquisition methods. A total motion score for each acquisition was calculated by summing the scores for each of the three lung zones, and the scores for the two imaging methods were compared. Correlation between degree of motion artifact and age was evaluated. Effective radiation doses were estimated for volumetric and axial CT acquisitions. RESULTS. The study population consisted of 54 children (28 boys, 26 girls; mean age, 11.7 ± 3.8 years; range, 5-18 years; eight inpatients, 46 outpatients) who underwent a total of 54 MDCT chest studies with volumetric and axial HRCT acquisitions. Motion artifact scores were higher for axial than for volumetric HRCT images of the upper (1.2 vs 1.0), middle (1.6 vs 1.2), and lower (2.2 vs 1.5) lung zones (p < 0.05 at each level). The total motion score of the axial HRCT images (mean, 5; range, 1-9) was higher than that of the volumetric HRCT images (mean, 3.6; range, 1-8) (p < 0.05). Younger age correlated with higher motion artifact score on axial HRCT images (r = -0.36, p < 0.01), whereas no correlation was found between age and motion artifact score on volumetric HRCT images (r = -0.12, p = 0.38). The effective radiation doses were 0.57 mSv for axial HRCT acquisition and 7.6 mSv for volumetric acquisition. The addition of axial acquisition increased the total radiation dose of the MDCT examination 7.1%. CONCLUSION. At CT of pediatric patients, reconstructed HRCT images from volumetric MDCT acquisition have significantly less motion artifact than images obtained with traditional axial acquisition.

Original languageEnglish
Pages (from-to)1414-1418
Number of pages5
JournalAmerican Journal of Roentgenology
Volume193
Issue number5
DOIs
StatePublished - Nov 1 2009
Externally publishedYes

Fingerprint

Cone-Beam Computed Tomography
Artifacts
Pediatrics
Radiation
Lung
Thorax
Hospital Information Systems
Interstitial Lung Diseases
Lung Diseases
Inpatients
Outpatients
Students

Keywords

  • Children
  • High-resolution CT
  • HRCT
  • MDCT
  • Motion artifact
  • Radiation dose

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Bastos, M. D. A., Lee, E. Y., Strauss, K. J., Zurakowski, D., Tracy, D. A., & Boiselle, P. M. (2009). Motion artifact on high-resolution CT images of pediatric patients: Comparison of volumetric and axial CT methods. American Journal of Roentgenology, 193(5), 1414-1418. https://doi.org/10.2214/AJR.09.2843

Motion artifact on high-resolution CT images of pediatric patients : Comparison of volumetric and axial CT methods. / Bastos, Maria D Almeida; Lee, Edward Y.; Strauss, Keith J.; Zurakowski, David; Tracy, Donald A.; Boiselle, Phillip M.

In: American Journal of Roentgenology, Vol. 193, No. 5, 01.11.2009, p. 1414-1418.

Research output: Contribution to journalArticle

Bastos, Maria D Almeida ; Lee, Edward Y. ; Strauss, Keith J. ; Zurakowski, David ; Tracy, Donald A. ; Boiselle, Phillip M. / Motion artifact on high-resolution CT images of pediatric patients : Comparison of volumetric and axial CT methods. In: American Journal of Roentgenology. 2009 ; Vol. 193, No. 5. pp. 1414-1418.
@article{0c5b45d241194e1c8d8f21524d6e53e3,
title = "Motion artifact on high-resolution CT images of pediatric patients: Comparison of volumetric and axial CT methods",
abstract = "OBJECTIVE. The purpose of this study was to address the controversy whether the quality of volumetric high-resolution CT (HRCT) images is as good as that of axial nonvolumetric HRCT images by assessing the degree of motion artifact on images acquired with the two methods at MDCT of pediatric patients with known or suspected lung disease. MATERIALS AND METHODS. A search of the hospital information system was conducted to identify the cases of pediatric patients with clinically suspected or known interstitial lung disease who underwent 16-MDCT of the chest with both volumetric and axial HRCT acquisitions (both 1.25-mm slice thickness) from March 2005 to July 2008. Two pediatric radiologists reviewed the images for the presence of motion artifacts at three anatomic levels (upper, middle, and lower lung zones). Motion artifacts were given numerical grades representing no artifact to severe artifact, and the paired Student's t test was used to compare the scores for the two acquisition methods. A total motion score for each acquisition was calculated by summing the scores for each of the three lung zones, and the scores for the two imaging methods were compared. Correlation between degree of motion artifact and age was evaluated. Effective radiation doses were estimated for volumetric and axial CT acquisitions. RESULTS. The study population consisted of 54 children (28 boys, 26 girls; mean age, 11.7 ± 3.8 years; range, 5-18 years; eight inpatients, 46 outpatients) who underwent a total of 54 MDCT chest studies with volumetric and axial HRCT acquisitions. Motion artifact scores were higher for axial than for volumetric HRCT images of the upper (1.2 vs 1.0), middle (1.6 vs 1.2), and lower (2.2 vs 1.5) lung zones (p < 0.05 at each level). The total motion score of the axial HRCT images (mean, 5; range, 1-9) was higher than that of the volumetric HRCT images (mean, 3.6; range, 1-8) (p < 0.05). Younger age correlated with higher motion artifact score on axial HRCT images (r = -0.36, p < 0.01), whereas no correlation was found between age and motion artifact score on volumetric HRCT images (r = -0.12, p = 0.38). The effective radiation doses were 0.57 mSv for axial HRCT acquisition and 7.6 mSv for volumetric acquisition. The addition of axial acquisition increased the total radiation dose of the MDCT examination 7.1{\%}. CONCLUSION. At CT of pediatric patients, reconstructed HRCT images from volumetric MDCT acquisition have significantly less motion artifact than images obtained with traditional axial acquisition.",
keywords = "Children, High-resolution CT, HRCT, MDCT, Motion artifact, Radiation dose",
author = "Bastos, {Maria D Almeida} and Lee, {Edward Y.} and Strauss, {Keith J.} and David Zurakowski and Tracy, {Donald A.} and Boiselle, {Phillip M.}",
year = "2009",
month = "11",
day = "1",
doi = "10.2214/AJR.09.2843",
language = "English",
volume = "193",
pages = "1414--1418",
journal = "AJR. American journal of roentgenology",
issn = "0361-803X",
publisher = "American Roentgen Ray Society",
number = "5",

}

TY - JOUR

T1 - Motion artifact on high-resolution CT images of pediatric patients

T2 - Comparison of volumetric and axial CT methods

AU - Bastos, Maria D Almeida

AU - Lee, Edward Y.

AU - Strauss, Keith J.

AU - Zurakowski, David

AU - Tracy, Donald A.

AU - Boiselle, Phillip M.

PY - 2009/11/1

Y1 - 2009/11/1

N2 - OBJECTIVE. The purpose of this study was to address the controversy whether the quality of volumetric high-resolution CT (HRCT) images is as good as that of axial nonvolumetric HRCT images by assessing the degree of motion artifact on images acquired with the two methods at MDCT of pediatric patients with known or suspected lung disease. MATERIALS AND METHODS. A search of the hospital information system was conducted to identify the cases of pediatric patients with clinically suspected or known interstitial lung disease who underwent 16-MDCT of the chest with both volumetric and axial HRCT acquisitions (both 1.25-mm slice thickness) from March 2005 to July 2008. Two pediatric radiologists reviewed the images for the presence of motion artifacts at three anatomic levels (upper, middle, and lower lung zones). Motion artifacts were given numerical grades representing no artifact to severe artifact, and the paired Student's t test was used to compare the scores for the two acquisition methods. A total motion score for each acquisition was calculated by summing the scores for each of the three lung zones, and the scores for the two imaging methods were compared. Correlation between degree of motion artifact and age was evaluated. Effective radiation doses were estimated for volumetric and axial CT acquisitions. RESULTS. The study population consisted of 54 children (28 boys, 26 girls; mean age, 11.7 ± 3.8 years; range, 5-18 years; eight inpatients, 46 outpatients) who underwent a total of 54 MDCT chest studies with volumetric and axial HRCT acquisitions. Motion artifact scores were higher for axial than for volumetric HRCT images of the upper (1.2 vs 1.0), middle (1.6 vs 1.2), and lower (2.2 vs 1.5) lung zones (p < 0.05 at each level). The total motion score of the axial HRCT images (mean, 5; range, 1-9) was higher than that of the volumetric HRCT images (mean, 3.6; range, 1-8) (p < 0.05). Younger age correlated with higher motion artifact score on axial HRCT images (r = -0.36, p < 0.01), whereas no correlation was found between age and motion artifact score on volumetric HRCT images (r = -0.12, p = 0.38). The effective radiation doses were 0.57 mSv for axial HRCT acquisition and 7.6 mSv for volumetric acquisition. The addition of axial acquisition increased the total radiation dose of the MDCT examination 7.1%. CONCLUSION. At CT of pediatric patients, reconstructed HRCT images from volumetric MDCT acquisition have significantly less motion artifact than images obtained with traditional axial acquisition.

AB - OBJECTIVE. The purpose of this study was to address the controversy whether the quality of volumetric high-resolution CT (HRCT) images is as good as that of axial nonvolumetric HRCT images by assessing the degree of motion artifact on images acquired with the two methods at MDCT of pediatric patients with known or suspected lung disease. MATERIALS AND METHODS. A search of the hospital information system was conducted to identify the cases of pediatric patients with clinically suspected or known interstitial lung disease who underwent 16-MDCT of the chest with both volumetric and axial HRCT acquisitions (both 1.25-mm slice thickness) from March 2005 to July 2008. Two pediatric radiologists reviewed the images for the presence of motion artifacts at three anatomic levels (upper, middle, and lower lung zones). Motion artifacts were given numerical grades representing no artifact to severe artifact, and the paired Student's t test was used to compare the scores for the two acquisition methods. A total motion score for each acquisition was calculated by summing the scores for each of the three lung zones, and the scores for the two imaging methods were compared. Correlation between degree of motion artifact and age was evaluated. Effective radiation doses were estimated for volumetric and axial CT acquisitions. RESULTS. The study population consisted of 54 children (28 boys, 26 girls; mean age, 11.7 ± 3.8 years; range, 5-18 years; eight inpatients, 46 outpatients) who underwent a total of 54 MDCT chest studies with volumetric and axial HRCT acquisitions. Motion artifact scores were higher for axial than for volumetric HRCT images of the upper (1.2 vs 1.0), middle (1.6 vs 1.2), and lower (2.2 vs 1.5) lung zones (p < 0.05 at each level). The total motion score of the axial HRCT images (mean, 5; range, 1-9) was higher than that of the volumetric HRCT images (mean, 3.6; range, 1-8) (p < 0.05). Younger age correlated with higher motion artifact score on axial HRCT images (r = -0.36, p < 0.01), whereas no correlation was found between age and motion artifact score on volumetric HRCT images (r = -0.12, p = 0.38). The effective radiation doses were 0.57 mSv for axial HRCT acquisition and 7.6 mSv for volumetric acquisition. The addition of axial acquisition increased the total radiation dose of the MDCT examination 7.1%. CONCLUSION. At CT of pediatric patients, reconstructed HRCT images from volumetric MDCT acquisition have significantly less motion artifact than images obtained with traditional axial acquisition.

KW - Children

KW - High-resolution CT

KW - HRCT

KW - MDCT

KW - Motion artifact

KW - Radiation dose

UR - http://www.scopus.com/inward/record.url?scp=70449510668&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70449510668&partnerID=8YFLogxK

U2 - 10.2214/AJR.09.2843

DO - 10.2214/AJR.09.2843

M3 - Article

C2 - 19843761

AN - SCOPUS:70449510668

VL - 193

SP - 1414

EP - 1418

JO - AJR. American journal of roentgenology

JF - AJR. American journal of roentgenology

SN - 0361-803X

IS - 5

ER -