Measurement of vessel diameter during angioplasty: Are we accurately performing this task?

Loay Salman, Roberto I Vazquez-Padron, Hector Castro, Mauricio Monrroy, Yehia Abdelwahed, Abid Rizvi, Donna Merrill, Arif Asif

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Vessel diameter is objectively measured by a lead ruler positioned in the fluoroscopic field and software calibration during angioplasty. We conducted a prospective study to evaluate the accuracy of lead ruler determination of vessel diameter. Chronic hemodialysis patients undergoing an angioplasty procedure were included in this study (n = 37). Vessel diameter was determined by calibrating the fluoroscopy machine to a ruler with lead markers placed in the fluoroscopic field. The same calibration was used to measure the fully effaced angioplasty balloon in its intravascular location. We compared the measured balloon diameter with the actual (manufacturer's) diameter. The approximate depth of the ruler from the measured vessel was also determined. Angioplasty balloons appeared 13.75-40.83% (mean 25.8% ± 7.015) smaller than the actual size of the balloon (p < 0.0001) when measured using a calibrated fluoroscopic machine. There was a tendency toward the fact that the bigger the distance between the ruler and the vessel (that contained the angioplasty balloon), the more likely the technique underestimated the size of the angioplasty balloon. Lead ruler method underestimates the diameter of the vessel. Recognizing such a discrepancy is important when determining the size of an angioplasty balloon or endovascular stent.

Original languageEnglish
JournalSeminars in Dialysis
Volume27
Issue number4
DOIs
StatePublished - Jan 1 2014

Fingerprint

Balloon Angioplasty
Angioplasty
Calibration
Fluoroscopy
Stents
Renal Dialysis
Software
Prospective Studies
Lead

ASJC Scopus subject areas

  • Nephrology

Cite this

Measurement of vessel diameter during angioplasty : Are we accurately performing this task? / Salman, Loay; Vazquez-Padron, Roberto I; Castro, Hector; Monrroy, Mauricio; Abdelwahed, Yehia; Rizvi, Abid; Merrill, Donna; Asif, Arif.

In: Seminars in Dialysis, Vol. 27, No. 4, 01.01.2014.

Research output: Contribution to journalArticle

Salman, Loay ; Vazquez-Padron, Roberto I ; Castro, Hector ; Monrroy, Mauricio ; Abdelwahed, Yehia ; Rizvi, Abid ; Merrill, Donna ; Asif, Arif. / Measurement of vessel diameter during angioplasty : Are we accurately performing this task?. In: Seminars in Dialysis. 2014 ; Vol. 27, No. 4.
@article{4a44a68d00e54908b7b06d1607839f9a,
title = "Measurement of vessel diameter during angioplasty: Are we accurately performing this task?",
abstract = "Vessel diameter is objectively measured by a lead ruler positioned in the fluoroscopic field and software calibration during angioplasty. We conducted a prospective study to evaluate the accuracy of lead ruler determination of vessel diameter. Chronic hemodialysis patients undergoing an angioplasty procedure were included in this study (n = 37). Vessel diameter was determined by calibrating the fluoroscopy machine to a ruler with lead markers placed in the fluoroscopic field. The same calibration was used to measure the fully effaced angioplasty balloon in its intravascular location. We compared the measured balloon diameter with the actual (manufacturer's) diameter. The approximate depth of the ruler from the measured vessel was also determined. Angioplasty balloons appeared 13.75-40.83{\%} (mean 25.8{\%} ± 7.015) smaller than the actual size of the balloon (p < 0.0001) when measured using a calibrated fluoroscopic machine. There was a tendency toward the fact that the bigger the distance between the ruler and the vessel (that contained the angioplasty balloon), the more likely the technique underestimated the size of the angioplasty balloon. Lead ruler method underestimates the diameter of the vessel. Recognizing such a discrepancy is important when determining the size of an angioplasty balloon or endovascular stent.",
author = "Loay Salman and Vazquez-Padron, {Roberto I} and Hector Castro and Mauricio Monrroy and Yehia Abdelwahed and Abid Rizvi and Donna Merrill and Arif Asif",
year = "2014",
month = "1",
day = "1",
doi = "10.1111/sdi.12164",
language = "English",
volume = "27",
journal = "Seminars in Dialysis",
issn = "0894-0959",
publisher = "Wiley-Blackwell",
number = "4",

}

TY - JOUR

T1 - Measurement of vessel diameter during angioplasty

T2 - Are we accurately performing this task?

AU - Salman, Loay

AU - Vazquez-Padron, Roberto I

AU - Castro, Hector

AU - Monrroy, Mauricio

AU - Abdelwahed, Yehia

AU - Rizvi, Abid

AU - Merrill, Donna

AU - Asif, Arif

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Vessel diameter is objectively measured by a lead ruler positioned in the fluoroscopic field and software calibration during angioplasty. We conducted a prospective study to evaluate the accuracy of lead ruler determination of vessel diameter. Chronic hemodialysis patients undergoing an angioplasty procedure were included in this study (n = 37). Vessel diameter was determined by calibrating the fluoroscopy machine to a ruler with lead markers placed in the fluoroscopic field. The same calibration was used to measure the fully effaced angioplasty balloon in its intravascular location. We compared the measured balloon diameter with the actual (manufacturer's) diameter. The approximate depth of the ruler from the measured vessel was also determined. Angioplasty balloons appeared 13.75-40.83% (mean 25.8% ± 7.015) smaller than the actual size of the balloon (p < 0.0001) when measured using a calibrated fluoroscopic machine. There was a tendency toward the fact that the bigger the distance between the ruler and the vessel (that contained the angioplasty balloon), the more likely the technique underestimated the size of the angioplasty balloon. Lead ruler method underestimates the diameter of the vessel. Recognizing such a discrepancy is important when determining the size of an angioplasty balloon or endovascular stent.

AB - Vessel diameter is objectively measured by a lead ruler positioned in the fluoroscopic field and software calibration during angioplasty. We conducted a prospective study to evaluate the accuracy of lead ruler determination of vessel diameter. Chronic hemodialysis patients undergoing an angioplasty procedure were included in this study (n = 37). Vessel diameter was determined by calibrating the fluoroscopy machine to a ruler with lead markers placed in the fluoroscopic field. The same calibration was used to measure the fully effaced angioplasty balloon in its intravascular location. We compared the measured balloon diameter with the actual (manufacturer's) diameter. The approximate depth of the ruler from the measured vessel was also determined. Angioplasty balloons appeared 13.75-40.83% (mean 25.8% ± 7.015) smaller than the actual size of the balloon (p < 0.0001) when measured using a calibrated fluoroscopic machine. There was a tendency toward the fact that the bigger the distance between the ruler and the vessel (that contained the angioplasty balloon), the more likely the technique underestimated the size of the angioplasty balloon. Lead ruler method underestimates the diameter of the vessel. Recognizing such a discrepancy is important when determining the size of an angioplasty balloon or endovascular stent.

UR - http://www.scopus.com/inward/record.url?scp=84904035512&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904035512&partnerID=8YFLogxK

U2 - 10.1111/sdi.12164

DO - 10.1111/sdi.12164

M3 - Article

C2 - 24262012

AN - SCOPUS:84904035512

VL - 27

JO - Seminars in Dialysis

JF - Seminars in Dialysis

SN - 0894-0959

IS - 4

ER -