Measurement of optic disc size and rim area with spectral-domain OCT and scanning laser ophthalmoscopy

Sasan Moghimi, Hamid Hosseini, Jay Riddle, Gina Yoo Lee, Elena Bitrian, Joann Giaconi, Joseph Caprioli, Kouros Nouri-Mahdavi

Research output: Contribution to journalArticlepeer-review

54 Scopus citations

Abstract

PURPOSE. To compare optic disc and neuroretinal rim area measurements from spectral-domain optical coherence tomography (SD-OCT) to those from confocal scanning laser ophthalmoscopy. METHODS. Seventy-one eyes from 43 normal subjects or suspected/definite glaucoma patients were prospectively enrolled. All subjects had biometry with the IOLMaster and disc/retinal nerve fiber layer imaging with Cirrus SD-OCT (Optic Disc Cube 200×200) and Heidelberg Retina Tomograph (HRT). Uncorrected disc and rim areas and measurements corrected for eye magnification with Bennett's formula (AL-corrected measurements), along with 30° sectoral rim areas, vertical cup-to-disc ratio (VCDR), and cup volume, were compared between the two devices. RESULTS. The median (range) axial length (AL) was 24.2 mm (22.4-27.7 mm). Mean keratometry-corrected HRT disc area measurements were larger than AL-corrected HRT and SD-OCT measurements (P < 0.001 for both) and the difference was a function of keratometry measurements (K-readings). The AL-corrected HRT disc area and uncorrected/corrected Cirrus disc areas were not significantly different (P > 0.481). HRT rim area was larger than Cirrus measurements (P < 0.001) and the difference decreased with decreasing rim area. HRT VCDR and cup volume were significantly smaller than Cirrus measurements (P < 0.001). The correlations for sectoral rim areas between the two devices were moderate at best (intraclass correlation coefficients 1/4 0.12-0.65). CONCLUSIONS. HRT overestimated optic disc area as compared to SD-OCT. A portion of the difference in HRT and SD-OCT disc measurements is due to HRT's magnification correction algorithm. Rim area measurements from HRT were larger than from SD-OCT, likely a result of different definitions for the reference plane and differences in disc area measurements. Disc parameters from the two devices are not interchangeable.

Original languageEnglish (US)
Pages (from-to)4519-4530
Number of pages12
JournalInvestigative Ophthalmology and Visual Science
Volume53
Issue number8
DOIs
StatePublished - Jul 2012
Externally publishedYes

ASJC Scopus subject areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Fingerprint

Dive into the research topics of 'Measurement of optic disc size and rim area with spectral-domain OCT and scanning laser ophthalmoscopy'. Together they form a unique fingerprint.

Cite this