Measurement of intracellular pH using flow cytometry with carboxy‐SNARF‐1

Eric D. Wieder, Haiying Hang, Michael H. Fox

Research output: Contribution to journalArticle

59 Scopus citations

Abstract

The new intracellular pH (pHi) dye carboxy‐seminaphthorhodafluor (SNARF‐1) was compared to the established dye 2,3‐dicyanohydroquinone (DCH) using flow cytometry. Both dyes give high‐resolution pHi measurements. SNARF‐1 remains trapped within cells much longer than DCH, so that pHi can be monitored during and after treatments with chemicals or hyperthermia. The toxicity of the dyes is similar, and both dyes can be used at concentrations that result in low toxicity to cells. Adequate staining of cells with SNARF‐1 is dependent on the cell concentration. The absolute pHi values indicated by SNARF‐1 are higher than values measured with DCH. However, the trends measured by both dyes are consistent, and both are useful for making pHi measurements. © 1993 Wiley‐Liss, Inc.

Original languageEnglish (US)
Pages (from-to)916-921
Number of pages6
JournalCytometry
Volume14
Issue number8
DOIs
StatePublished - Nov 1993
Externally publishedYes

Keywords

  • Dicyanohydroquinone
  • SNARF‐1
  • flow cytometry
  • intracellular pH