Mathematical model of flow-injection analysis. First-order chemical reaction in a straight tube

V. P. Andreev, M. I. Khidekel

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

A mathematical model of flow-injection analysis (FIA) is developed for a pseudo-first-order chemical reaction in a straight reaction tube. Analytical expressions are derived for the first three moments of the peaks of the sample and product of the chemical reaction. A comparison with the available numerical analysis and experimental results is given. The application of the model to FIA optimization is described.

Original languageEnglish
Pages (from-to)307-316
Number of pages10
JournalAnalytica Chimica Acta
Volume278
Issue number2
DOIs
StatePublished - Jun 22 1993

Fingerprint

Flow Injection Analysis
chemical reaction
Chemical reactions
Theoretical Models
Mathematical models
Numerical analysis
analysis

Keywords

  • Flow injection
  • Mathematical model

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Mathematical model of flow-injection analysis. First-order chemical reaction in a straight tube. / Andreev, V. P.; Khidekel, M. I.

In: Analytica Chimica Acta, Vol. 278, No. 2, 22.06.1993, p. 307-316.

Research output: Contribution to journalArticle

Andreev, V. P. ; Khidekel, M. I. / Mathematical model of flow-injection analysis. First-order chemical reaction in a straight tube. In: Analytica Chimica Acta. 1993 ; Vol. 278, No. 2. pp. 307-316.
@article{2f42e639ebe94975970dc1653560d3bc,
title = "Mathematical model of flow-injection analysis. First-order chemical reaction in a straight tube",
abstract = "A mathematical model of flow-injection analysis (FIA) is developed for a pseudo-first-order chemical reaction in a straight reaction tube. Analytical expressions are derived for the first three moments of the peaks of the sample and product of the chemical reaction. A comparison with the available numerical analysis and experimental results is given. The application of the model to FIA optimization is described.",
keywords = "Flow injection, Mathematical model",
author = "Andreev, {V. P.} and Khidekel, {M. I.}",
year = "1993",
month = "6",
day = "22",
doi = "10.1016/0003-2670(93)85114-Y",
language = "English",
volume = "278",
pages = "307--316",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Mathematical model of flow-injection analysis. First-order chemical reaction in a straight tube

AU - Andreev, V. P.

AU - Khidekel, M. I.

PY - 1993/6/22

Y1 - 1993/6/22

N2 - A mathematical model of flow-injection analysis (FIA) is developed for a pseudo-first-order chemical reaction in a straight reaction tube. Analytical expressions are derived for the first three moments of the peaks of the sample and product of the chemical reaction. A comparison with the available numerical analysis and experimental results is given. The application of the model to FIA optimization is described.

AB - A mathematical model of flow-injection analysis (FIA) is developed for a pseudo-first-order chemical reaction in a straight reaction tube. Analytical expressions are derived for the first three moments of the peaks of the sample and product of the chemical reaction. A comparison with the available numerical analysis and experimental results is given. The application of the model to FIA optimization is described.

KW - Flow injection

KW - Mathematical model

UR - http://www.scopus.com/inward/record.url?scp=0027180825&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027180825&partnerID=8YFLogxK

U2 - 10.1016/0003-2670(93)85114-Y

DO - 10.1016/0003-2670(93)85114-Y

M3 - Article

AN - SCOPUS:0027180825

VL - 278

SP - 307

EP - 316

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 2

ER -