Magnetoelastic transducers for monitoring coagulation, clot inhibition, and fibrinolysis

Libby G. Puckett, Jaime K. Lewis, Aaron Urbas, Xiangdong Cui, Dayong Gao, Leonidas G Bachas

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

Magnetoelastic transduction has been used to detect and monitor the viscosity changes that occur during the biological reactions of coagulation and fibrinolysis. Magnetoelastic sensors can be used, because the characteristic resonance frequency of the magnetoelastic strip shifts in response to the changes in fluid viscosity. At a set frequency, the output signal can be obtained over time to develop a coagulation and/or dissolution profile, which display the change in viscosity of a plasma sample that has undergone either coagulation or fibrinolysis. For coagulation screening, an exogenous tissue factor is added to an anticoagulated plasma sample to initiate coagulation. Further studies were performed to investigate fibrinolysis through the addition of plasmin. Plasmin is used in two different ways - as a competitive inhibitor before the initiation of clotting and also as a protease to dissolve the previously formed clot. This method is a viable option for the monitoring of processes that are paramount to maintaining hemostasis.

Original languageEnglish (US)
Pages (from-to)1737-1743
Number of pages7
JournalBiosensors and Bioelectronics
Volume20
Issue number9
DOIs
StatePublished - Mar 15 2005
Externally publishedYes

Fingerprint

Fibrinolysis
Coagulation
Transducers
Viscosity
Fibrinolysin
Monitoring
Thromboplastin
Hemostasis
Peptide Hydrolases
Plasmas
Screening
Dissolution
Tissue
Fluids
Sensors

Keywords

  • Blood coagulation
  • Fibrinolysis
  • Magnetoelastic transduction
  • Plasmin
  • Thromboplastin

ASJC Scopus subject areas

  • Biotechnology
  • Analytical Chemistry
  • Electrochemistry

Cite this

Magnetoelastic transducers for monitoring coagulation, clot inhibition, and fibrinolysis. / Puckett, Libby G.; Lewis, Jaime K.; Urbas, Aaron; Cui, Xiangdong; Gao, Dayong; Bachas, Leonidas G.

In: Biosensors and Bioelectronics, Vol. 20, No. 9, 15.03.2005, p. 1737-1743.

Research output: Contribution to journalArticle

Puckett, Libby G. ; Lewis, Jaime K. ; Urbas, Aaron ; Cui, Xiangdong ; Gao, Dayong ; Bachas, Leonidas G. / Magnetoelastic transducers for monitoring coagulation, clot inhibition, and fibrinolysis. In: Biosensors and Bioelectronics. 2005 ; Vol. 20, No. 9. pp. 1737-1743.
@article{25d7ae6b79644384a21fad283540d587,
title = "Magnetoelastic transducers for monitoring coagulation, clot inhibition, and fibrinolysis",
abstract = "Magnetoelastic transduction has been used to detect and monitor the viscosity changes that occur during the biological reactions of coagulation and fibrinolysis. Magnetoelastic sensors can be used, because the characteristic resonance frequency of the magnetoelastic strip shifts in response to the changes in fluid viscosity. At a set frequency, the output signal can be obtained over time to develop a coagulation and/or dissolution profile, which display the change in viscosity of a plasma sample that has undergone either coagulation or fibrinolysis. For coagulation screening, an exogenous tissue factor is added to an anticoagulated plasma sample to initiate coagulation. Further studies were performed to investigate fibrinolysis through the addition of plasmin. Plasmin is used in two different ways - as a competitive inhibitor before the initiation of clotting and also as a protease to dissolve the previously formed clot. This method is a viable option for the monitoring of processes that are paramount to maintaining hemostasis.",
keywords = "Blood coagulation, Fibrinolysis, Magnetoelastic transduction, Plasmin, Thromboplastin",
author = "Puckett, {Libby G.} and Lewis, {Jaime K.} and Aaron Urbas and Xiangdong Cui and Dayong Gao and Bachas, {Leonidas G}",
year = "2005",
month = "3",
day = "15",
doi = "10.1016/j.bios.2004.06.051",
language = "English (US)",
volume = "20",
pages = "1737--1743",
journal = "Biosensors",
issn = "0956-5663",
publisher = "Elsevier Limited",
number = "9",

}

TY - JOUR

T1 - Magnetoelastic transducers for monitoring coagulation, clot inhibition, and fibrinolysis

AU - Puckett, Libby G.

AU - Lewis, Jaime K.

AU - Urbas, Aaron

AU - Cui, Xiangdong

AU - Gao, Dayong

AU - Bachas, Leonidas G

PY - 2005/3/15

Y1 - 2005/3/15

N2 - Magnetoelastic transduction has been used to detect and monitor the viscosity changes that occur during the biological reactions of coagulation and fibrinolysis. Magnetoelastic sensors can be used, because the characteristic resonance frequency of the magnetoelastic strip shifts in response to the changes in fluid viscosity. At a set frequency, the output signal can be obtained over time to develop a coagulation and/or dissolution profile, which display the change in viscosity of a plasma sample that has undergone either coagulation or fibrinolysis. For coagulation screening, an exogenous tissue factor is added to an anticoagulated plasma sample to initiate coagulation. Further studies were performed to investigate fibrinolysis through the addition of plasmin. Plasmin is used in two different ways - as a competitive inhibitor before the initiation of clotting and also as a protease to dissolve the previously formed clot. This method is a viable option for the monitoring of processes that are paramount to maintaining hemostasis.

AB - Magnetoelastic transduction has been used to detect and monitor the viscosity changes that occur during the biological reactions of coagulation and fibrinolysis. Magnetoelastic sensors can be used, because the characteristic resonance frequency of the magnetoelastic strip shifts in response to the changes in fluid viscosity. At a set frequency, the output signal can be obtained over time to develop a coagulation and/or dissolution profile, which display the change in viscosity of a plasma sample that has undergone either coagulation or fibrinolysis. For coagulation screening, an exogenous tissue factor is added to an anticoagulated plasma sample to initiate coagulation. Further studies were performed to investigate fibrinolysis through the addition of plasmin. Plasmin is used in two different ways - as a competitive inhibitor before the initiation of clotting and also as a protease to dissolve the previously formed clot. This method is a viable option for the monitoring of processes that are paramount to maintaining hemostasis.

KW - Blood coagulation

KW - Fibrinolysis

KW - Magnetoelastic transduction

KW - Plasmin

KW - Thromboplastin

UR - http://www.scopus.com/inward/record.url?scp=12844279384&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12844279384&partnerID=8YFLogxK

U2 - 10.1016/j.bios.2004.06.051

DO - 10.1016/j.bios.2004.06.051

M3 - Article

C2 - 15681188

AN - SCOPUS:12844279384

VL - 20

SP - 1737

EP - 1743

JO - Biosensors

JF - Biosensors

SN - 0956-5663

IS - 9

ER -