Magnetic resonance imaging-guided renal artery stent placement in a swine model: Comparison of two tracking techniques

B. B. Frericks, D. R. Elgort, C. Hillenbrand, J. L. Duerk, J. S. Lewin, F. K. Wacker

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Background: Magnetic resonance (MR)-guided interventions have evolved from a pure research application to a preclinical method over the last decade. Among the device-tracking techniques, susceptibility artifact-based tracking relies on the contrast between the surrounding blood and the device, and radiofrequency coil-based tracking relies on the local gradient field amplification in a resonating circuit attached to the interventional device. Purpose: To evaluate the feasibility and precision of susceptibility artifact-based and microcoil-based MR guidance methods for renal artery stent placement in a swine model. Material and Methods: MR imaging-guided renal artery stent placements were performed in six fully anesthetized pigs using a 1.5T short-bore MR scanner. Susceptibility artifact-based tracking with manual scan-plane adjustments and microcoil tracking with automatic scan-plane adjustments were used for renal artery stent placements in three pigs in each group. With both methods, near real-time steady-state free-precession (SSFP) imaging was used. Differences between the two tracking approaches on stenting time, total procedure time, and stent position were measured. Results: The microcoil-based approach yielded a shorter mean procedure time (17 vs. 23 min). There was no relevant difference for the mean stenting time (12 vs. 13 min). The mean stent deviation from the aortic wall with the susceptibility approach was larger than with the microcoil approach (10 vs. 4.0 mm). Conclusion: For MRI-guided renal artery stent placement, the microcoil-based technique had a shorter procedure time and a higher stent placement precision than the susceptibility artifact-based approach.

Original languageEnglish (US)
Pages (from-to)21-27
Number of pages7
JournalActa Radiologica
Volume50
Issue number1
DOIs
StatePublished - 2009
Externally publishedYes

Keywords

  • Catheter tracking
  • Interventional MRI
  • MRI-guided procedures
  • Real-time imaging
  • Renal artery angioplasty
  • Renal artery stent

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Magnetic resonance imaging-guided renal artery stent placement in a swine model: Comparison of two tracking techniques'. Together they form a unique fingerprint.

Cite this