Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter

S. Saksena, P. P. Tarjan, S. Bharati, B. Boveja, D. Cohen, T. Joubert, M. Lev

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

A single suction electrode catheter was used for His bundle electrogram recording, His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysologic studies were performed in the control state, immediately after, and late (> 40 days) after His bundle ablation and results were correlated with histologic findings in the conduction system. Unipolar His bundle recording and pacing were successfully performed in all dogs with the suction electrode catheter before and after ablation. Complete heart block developed after a single 20 J shock delivered via the suction electrode catheter in all dogs immediately, but reverted to 1:1 atrioventricular conduction with first-degree atrioventricular block in two dogs in which one or two additional shocks (20 or 30 J) produced complete heart block. Mean ablation energy per shock was 22 ± 4 J. The mean total delivered energy per dog was 31 ± 20 J. Late electrophysiologic study in all dogs showed persistent complete heart block in five dogs and paroxysmal second-degree or third-degree atrioventricular block in two dogs. Gross examination of the ablation site showed a white plaque above the medial tricuspid leaflet (1.4 to 2.0 cm long and 0.4 to 0.6 cm wide). Microscopically, fibrosis of the penetrating and branching His bundle was seen in all dogs, with minimal atrioventricular node and atrial involvement. Significant proximal right bundle branch fibrosis was observe in two dogs receiving one or two additional shocks. We conclude that the suction electrode catheter permits repeated His bundle recording, pacing, and ablation with a single catheter. Permanent and safe low-energy ablation of the canine His bundle is feasible. Focal injury localized to the target area in the conduction system can be obtained.

Original languageEnglish
Pages (from-to)394-403
Number of pages10
JournalCirculation
Volume76
Issue number2
StatePublished - Nov 4 1987

Fingerprint

Suction
Bundle of His
Canidae
Electrodes
Catheters
Dogs
Heart Block
Shock
Atrioventricular Block
Fibrosis
Cardiac Electrophysiologic Techniques
Endocardium
Atrioventricular Node
Wounds and Injuries

ASJC Scopus subject areas

  • Physiology
  • Cardiology and Cardiovascular Medicine

Cite this

Saksena, S., Tarjan, P. P., Bharati, S., Boveja, B., Cohen, D., Joubert, T., & Lev, M. (1987). Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter. Circulation, 76(2), 394-403.

Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter. / Saksena, S.; Tarjan, P. P.; Bharati, S.; Boveja, B.; Cohen, D.; Joubert, T.; Lev, M.

In: Circulation, Vol. 76, No. 2, 04.11.1987, p. 394-403.

Research output: Contribution to journalArticle

Saksena, S, Tarjan, PP, Bharati, S, Boveja, B, Cohen, D, Joubert, T & Lev, M 1987, 'Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter', Circulation, vol. 76, no. 2, pp. 394-403.
Saksena S, Tarjan PP, Bharati S, Boveja B, Cohen D, Joubert T et al. Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter. Circulation. 1987 Nov 4;76(2):394-403.
Saksena, S. ; Tarjan, P. P. ; Bharati, S. ; Boveja, B. ; Cohen, D. ; Joubert, T. ; Lev, M. / Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter. In: Circulation. 1987 ; Vol. 76, No. 2. pp. 394-403.
@article{9d7d2f4e49d4420d96c3742de9353b64,
title = "Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter",
abstract = "A single suction electrode catheter was used for His bundle electrogram recording, His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysologic studies were performed in the control state, immediately after, and late (> 40 days) after His bundle ablation and results were correlated with histologic findings in the conduction system. Unipolar His bundle recording and pacing were successfully performed in all dogs with the suction electrode catheter before and after ablation. Complete heart block developed after a single 20 J shock delivered via the suction electrode catheter in all dogs immediately, but reverted to 1:1 atrioventricular conduction with first-degree atrioventricular block in two dogs in which one or two additional shocks (20 or 30 J) produced complete heart block. Mean ablation energy per shock was 22 ± 4 J. The mean total delivered energy per dog was 31 ± 20 J. Late electrophysiologic study in all dogs showed persistent complete heart block in five dogs and paroxysmal second-degree or third-degree atrioventricular block in two dogs. Gross examination of the ablation site showed a white plaque above the medial tricuspid leaflet (1.4 to 2.0 cm long and 0.4 to 0.6 cm wide). Microscopically, fibrosis of the penetrating and branching His bundle was seen in all dogs, with minimal atrioventricular node and atrial involvement. Significant proximal right bundle branch fibrosis was observe in two dogs receiving one or two additional shocks. We conclude that the suction electrode catheter permits repeated His bundle recording, pacing, and ablation with a single catheter. Permanent and safe low-energy ablation of the canine His bundle is feasible. Focal injury localized to the target area in the conduction system can be obtained.",
author = "S. Saksena and Tarjan, {P. P.} and S. Bharati and B. Boveja and D. Cohen and T. Joubert and M. Lev",
year = "1987",
month = "11",
day = "4",
language = "English",
volume = "76",
pages = "394--403",
journal = "Circulation",
issn = "0009-7322",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Low-energy transvenous ablation of the canine atrioventricular conduction system with a suction electrode catheter

AU - Saksena, S.

AU - Tarjan, P. P.

AU - Bharati, S.

AU - Boveja, B.

AU - Cohen, D.

AU - Joubert, T.

AU - Lev, M.

PY - 1987/11/4

Y1 - 1987/11/4

N2 - A single suction electrode catheter was used for His bundle electrogram recording, His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysologic studies were performed in the control state, immediately after, and late (> 40 days) after His bundle ablation and results were correlated with histologic findings in the conduction system. Unipolar His bundle recording and pacing were successfully performed in all dogs with the suction electrode catheter before and after ablation. Complete heart block developed after a single 20 J shock delivered via the suction electrode catheter in all dogs immediately, but reverted to 1:1 atrioventricular conduction with first-degree atrioventricular block in two dogs in which one or two additional shocks (20 or 30 J) produced complete heart block. Mean ablation energy per shock was 22 ± 4 J. The mean total delivered energy per dog was 31 ± 20 J. Late electrophysiologic study in all dogs showed persistent complete heart block in five dogs and paroxysmal second-degree or third-degree atrioventricular block in two dogs. Gross examination of the ablation site showed a white plaque above the medial tricuspid leaflet (1.4 to 2.0 cm long and 0.4 to 0.6 cm wide). Microscopically, fibrosis of the penetrating and branching His bundle was seen in all dogs, with minimal atrioventricular node and atrial involvement. Significant proximal right bundle branch fibrosis was observe in two dogs receiving one or two additional shocks. We conclude that the suction electrode catheter permits repeated His bundle recording, pacing, and ablation with a single catheter. Permanent and safe low-energy ablation of the canine His bundle is feasible. Focal injury localized to the target area in the conduction system can be obtained.

AB - A single suction electrode catheter was used for His bundle electrogram recording, His bundle pacing, and low-energy (20 or 30 J) His bundle ablation in seven dogs. The suction electrode catheter was actively fixed to the atrial endocardium at the His bundle level. Electrophysologic studies were performed in the control state, immediately after, and late (> 40 days) after His bundle ablation and results were correlated with histologic findings in the conduction system. Unipolar His bundle recording and pacing were successfully performed in all dogs with the suction electrode catheter before and after ablation. Complete heart block developed after a single 20 J shock delivered via the suction electrode catheter in all dogs immediately, but reverted to 1:1 atrioventricular conduction with first-degree atrioventricular block in two dogs in which one or two additional shocks (20 or 30 J) produced complete heart block. Mean ablation energy per shock was 22 ± 4 J. The mean total delivered energy per dog was 31 ± 20 J. Late electrophysiologic study in all dogs showed persistent complete heart block in five dogs and paroxysmal second-degree or third-degree atrioventricular block in two dogs. Gross examination of the ablation site showed a white plaque above the medial tricuspid leaflet (1.4 to 2.0 cm long and 0.4 to 0.6 cm wide). Microscopically, fibrosis of the penetrating and branching His bundle was seen in all dogs, with minimal atrioventricular node and atrial involvement. Significant proximal right bundle branch fibrosis was observe in two dogs receiving one or two additional shocks. We conclude that the suction electrode catheter permits repeated His bundle recording, pacing, and ablation with a single catheter. Permanent and safe low-energy ablation of the canine His bundle is feasible. Focal injury localized to the target area in the conduction system can be obtained.

UR - http://www.scopus.com/inward/record.url?scp=0023259456&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023259456&partnerID=8YFLogxK

M3 - Article

VL - 76

SP - 394

EP - 403

JO - Circulation

JF - Circulation

SN - 0009-7322

IS - 2

ER -