Laser-assisted corneal welding in cataract surgery

Retrospective study

Luca Menabuoni, Roberto Pini, Francesca Rossi, Ivo Lenzetti, Sonia H Yoo, Jean-Marie A Parel

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Purpose: To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Setting: Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. Methods: This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. Results: There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Conclusions: Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.

Original languageEnglish
Pages (from-to)1608-1612
Number of pages5
JournalJournal of Cataract and Refractive Surgery
Volume33
Issue number9
DOIs
StatePublished - Jan 1 2007

Fingerprint

Welding
Cataract
Lasers
Retrospective Studies
Astigmatism
Cataract Extraction
Phacoemulsification
Wounds and Injuries
Endothelial Cells
Inflammation
Semiconductor Lasers
Penetrating Keratoplasty
Hospital Departments
Ophthalmology
Italy
Visual Acuity
Animal Models
Cell Count

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Laser-assisted corneal welding in cataract surgery : Retrospective study. / Menabuoni, Luca; Pini, Roberto; Rossi, Francesca; Lenzetti, Ivo; Yoo, Sonia H; Parel, Jean-Marie A.

In: Journal of Cataract and Refractive Surgery, Vol. 33, No. 9, 01.01.2007, p. 1608-1612.

Research output: Contribution to journalArticle

Menabuoni, Luca ; Pini, Roberto ; Rossi, Francesca ; Lenzetti, Ivo ; Yoo, Sonia H ; Parel, Jean-Marie A. / Laser-assisted corneal welding in cataract surgery : Retrospective study. In: Journal of Cataract and Refractive Surgery. 2007 ; Vol. 33, No. 9. pp. 1608-1612.
@article{409ee5ba93b54641b51a89df129e9b6c,
title = "Laser-assisted corneal welding in cataract surgery: Retrospective study",
abstract = "Purpose: To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Setting: Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. Methods: This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. Results: There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Conclusions: Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.",
author = "Luca Menabuoni and Roberto Pini and Francesca Rossi and Ivo Lenzetti and Yoo, {Sonia H} and Parel, {Jean-Marie A}",
year = "2007",
month = "1",
day = "1",
doi = "10.1016/j.jcrs.2007.04.013",
language = "English",
volume = "33",
pages = "1608--1612",
journal = "Journal of Cataract and Refractive Surgery",
issn = "0886-3350",
publisher = "Elsevier Inc.",
number = "9",

}

TY - JOUR

T1 - Laser-assisted corneal welding in cataract surgery

T2 - Retrospective study

AU - Menabuoni, Luca

AU - Pini, Roberto

AU - Rossi, Francesca

AU - Lenzetti, Ivo

AU - Yoo, Sonia H

AU - Parel, Jean-Marie A

PY - 2007/1/1

Y1 - 2007/1/1

N2 - Purpose: To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Setting: Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. Methods: This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. Results: There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Conclusions: Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.

AB - Purpose: To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Setting: Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. Methods: This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. Results: There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Conclusions: Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.

UR - http://www.scopus.com/inward/record.url?scp=34548129556&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34548129556&partnerID=8YFLogxK

U2 - 10.1016/j.jcrs.2007.04.013

DO - 10.1016/j.jcrs.2007.04.013

M3 - Article

VL - 33

SP - 1608

EP - 1612

JO - Journal of Cataract and Refractive Surgery

JF - Journal of Cataract and Refractive Surgery

SN - 0886-3350

IS - 9

ER -