Isoelectric focusing in a Sephadex column

T. J. O'Brien, H. H. Liebke, Herman S Cheung, L. K. Johnson

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

An isoelectric focusing technique on a Sephadex column is described. This technique provides for the fractionation of amphoteric compounds in a pH gradient and allows for better than 95% recovery of the focused material. Focusing in this system over a pH range of 3.5-10 reaches equilibrium in approximately 5 hr and thereby reduces the exposure of more labile proteins to long focusing times.

Original languageEnglish
Pages (from-to)38-44
Number of pages7
JournalAnalytical Biochemistry
Volume72
Issue number1-2
DOIs
StatePublished - May 7 1976
Externally publishedYes

Fingerprint

Proton-Motive Force
Isoelectric Focusing
Fractionation
Recovery
Proteins
sephadex

ASJC Scopus subject areas

  • Biochemistry
  • Biophysics
  • Molecular Biology

Cite this

Isoelectric focusing in a Sephadex column. / O'Brien, T. J.; Liebke, H. H.; Cheung, Herman S; Johnson, L. K.

In: Analytical Biochemistry, Vol. 72, No. 1-2, 07.05.1976, p. 38-44.

Research output: Contribution to journalArticle

O'Brien, T. J. ; Liebke, H. H. ; Cheung, Herman S ; Johnson, L. K. / Isoelectric focusing in a Sephadex column. In: Analytical Biochemistry. 1976 ; Vol. 72, No. 1-2. pp. 38-44.
@article{4969c69459ab4762aa8ed5a09bf99571,
title = "Isoelectric focusing in a Sephadex column",
abstract = "An isoelectric focusing technique on a Sephadex column is described. This technique provides for the fractionation of amphoteric compounds in a pH gradient and allows for better than 95{\%} recovery of the focused material. Focusing in this system over a pH range of 3.5-10 reaches equilibrium in approximately 5 hr and thereby reduces the exposure of more labile proteins to long focusing times.",
author = "O'Brien, {T. J.} and Liebke, {H. H.} and Cheung, {Herman S} and Johnson, {L. K.}",
year = "1976",
month = "5",
day = "7",
doi = "10.1016/0003-2697(76)90503-0",
language = "English",
volume = "72",
pages = "38--44",
journal = "Analytical Biochemistry",
issn = "0003-2697",
publisher = "Academic Press Inc.",
number = "1-2",

}

TY - JOUR

T1 - Isoelectric focusing in a Sephadex column

AU - O'Brien, T. J.

AU - Liebke, H. H.

AU - Cheung, Herman S

AU - Johnson, L. K.

PY - 1976/5/7

Y1 - 1976/5/7

N2 - An isoelectric focusing technique on a Sephadex column is described. This technique provides for the fractionation of amphoteric compounds in a pH gradient and allows for better than 95% recovery of the focused material. Focusing in this system over a pH range of 3.5-10 reaches equilibrium in approximately 5 hr and thereby reduces the exposure of more labile proteins to long focusing times.

AB - An isoelectric focusing technique on a Sephadex column is described. This technique provides for the fractionation of amphoteric compounds in a pH gradient and allows for better than 95% recovery of the focused material. Focusing in this system over a pH range of 3.5-10 reaches equilibrium in approximately 5 hr and thereby reduces the exposure of more labile proteins to long focusing times.

UR - http://www.scopus.com/inward/record.url?scp=0017084467&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017084467&partnerID=8YFLogxK

U2 - 10.1016/0003-2697(76)90503-0

DO - 10.1016/0003-2697(76)90503-0

M3 - Article

C2 - 942059

AN - SCOPUS:0017084467

VL - 72

SP - 38

EP - 44

JO - Analytical Biochemistry

JF - Analytical Biochemistry

SN - 0003-2697

IS - 1-2

ER -