Is it safe to remove an infected cardiac implantable electronic device at the time of heart transplantation? Report of two cases

Christian Donato-Santana, Matthias Loebe, Nicolas Brozzi, Sandra Chaparro, Eugene J. Bauerlein, Amit Badiye, Ali Ghodsizad, Jacques Simkins

Research output: Contribution to journalArticle

Abstract

Cardiac implantable electronic device (CIED) infections are treated with antibiotics and device explantation. Lack of CIED removal is associated with infection recurrence. However, CIED removal can be associated with major complications including death. We reported two patients with advanced heart disease who developed CIED infection due Staphylococcus epidermidis while awaiting for orthotopic heart transplantation (OHT). Both patients were managed with a different approach. They were treated with antibiotic therapy and had their CIED removal postponed until OHT. Both patients were kept on suppressive antibiotic treatment until undergoing simultaneous OHT and removal of infected CIED. None of the patients had infection recurrence. Large studies are needed to assess whether the approach of delaying CIED removal until OHT is safe among carefully selected patients with CIED infection.

Original languageEnglish (US)
JournalJournal of cardiac surgery
DOIs
StateAccepted/In press - Jan 1 2019

Fingerprint

Device Removal
Heart Transplantation
Equipment and Supplies
Infection
Anti-Bacterial Agents
Recurrence
Staphylococcus epidermidis
Heart Diseases
Therapeutics

Keywords

  • cardiac implantable electronic device
  • heart transplantation
  • infection
  • Staphylococcus epidermidis

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Cite this

Is it safe to remove an infected cardiac implantable electronic device at the time of heart transplantation? Report of two cases. / Donato-Santana, Christian; Loebe, Matthias; Brozzi, Nicolas; Chaparro, Sandra; Bauerlein, Eugene J.; Badiye, Amit; Ghodsizad, Ali; Simkins, Jacques.

In: Journal of cardiac surgery, 01.01.2019.

Research output: Contribution to journalArticle

@article{b5916108020c4549bdfb5ae8b2fd50c7,
title = "Is it safe to remove an infected cardiac implantable electronic device at the time of heart transplantation? Report of two cases",
abstract = "Cardiac implantable electronic device (CIED) infections are treated with antibiotics and device explantation. Lack of CIED removal is associated with infection recurrence. However, CIED removal can be associated with major complications including death. We reported two patients with advanced heart disease who developed CIED infection due Staphylococcus epidermidis while awaiting for orthotopic heart transplantation (OHT). Both patients were managed with a different approach. They were treated with antibiotic therapy and had their CIED removal postponed until OHT. Both patients were kept on suppressive antibiotic treatment until undergoing simultaneous OHT and removal of infected CIED. None of the patients had infection recurrence. Large studies are needed to assess whether the approach of delaying CIED removal until OHT is safe among carefully selected patients with CIED infection.",
keywords = "cardiac implantable electronic device, heart transplantation, infection, Staphylococcus epidermidis",
author = "Christian Donato-Santana and Matthias Loebe and Nicolas Brozzi and Sandra Chaparro and Bauerlein, {Eugene J.} and Amit Badiye and Ali Ghodsizad and Jacques Simkins",
year = "2019",
month = "1",
day = "1",
doi = "10.1111/jocs.14279",
language = "English (US)",
journal = "Journal of Cardiac Surgery",
issn = "0886-0440",
publisher = "Wiley-Blackwell",

}

TY - JOUR

T1 - Is it safe to remove an infected cardiac implantable electronic device at the time of heart transplantation? Report of two cases

AU - Donato-Santana, Christian

AU - Loebe, Matthias

AU - Brozzi, Nicolas

AU - Chaparro, Sandra

AU - Bauerlein, Eugene J.

AU - Badiye, Amit

AU - Ghodsizad, Ali

AU - Simkins, Jacques

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Cardiac implantable electronic device (CIED) infections are treated with antibiotics and device explantation. Lack of CIED removal is associated with infection recurrence. However, CIED removal can be associated with major complications including death. We reported two patients with advanced heart disease who developed CIED infection due Staphylococcus epidermidis while awaiting for orthotopic heart transplantation (OHT). Both patients were managed with a different approach. They were treated with antibiotic therapy and had their CIED removal postponed until OHT. Both patients were kept on suppressive antibiotic treatment until undergoing simultaneous OHT and removal of infected CIED. None of the patients had infection recurrence. Large studies are needed to assess whether the approach of delaying CIED removal until OHT is safe among carefully selected patients with CIED infection.

AB - Cardiac implantable electronic device (CIED) infections are treated with antibiotics and device explantation. Lack of CIED removal is associated with infection recurrence. However, CIED removal can be associated with major complications including death. We reported two patients with advanced heart disease who developed CIED infection due Staphylococcus epidermidis while awaiting for orthotopic heart transplantation (OHT). Both patients were managed with a different approach. They were treated with antibiotic therapy and had their CIED removal postponed until OHT. Both patients were kept on suppressive antibiotic treatment until undergoing simultaneous OHT and removal of infected CIED. None of the patients had infection recurrence. Large studies are needed to assess whether the approach of delaying CIED removal until OHT is safe among carefully selected patients with CIED infection.

KW - cardiac implantable electronic device

KW - heart transplantation

KW - infection

KW - Staphylococcus epidermidis

UR - http://www.scopus.com/inward/record.url?scp=85074369748&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85074369748&partnerID=8YFLogxK

U2 - 10.1111/jocs.14279

DO - 10.1111/jocs.14279

M3 - Article

C2 - 31609492

AN - SCOPUS:85074369748

JO - Journal of Cardiac Surgery

JF - Journal of Cardiac Surgery

SN - 0886-0440

ER -