Intraocular Lens Calculation in Combined Penetrating Keratoplasty, Cataract Extraction and Intraocular Lens Implantation

Harold R. Katz, Richard K. Forster

Research output: Contribution to journalArticlepeer-review

34 Scopus citations

Abstract

We retrospectively studied 53 consecutive triple procedures (combined penetrating keratoplasty, cataract extraction and intraocular lens implantation) performed at the Bascom Palmer Eye Institute from January 1980 through August 1983. Most patients had at least six months of follow-up. The final postoperative refractive error was compared to the predicted refractive error using the preoperative axial length and the estimated keratometry readings. The deviation from the predicted refractive error was correlated with the source of preoperative keratometry readings, the degree of donor oversize, and the donor age. We found that using keratometry readings from the operated eye resulted in more accurate intraocular lens calculations than using estimated keratometry readings not obtained from either eye (P < .05).

Original languageEnglish (US)
Pages (from-to)1203-1207
Number of pages5
JournalOphthalmology
Volume92
Issue number9
DOIs
StatePublished - Jan 1 1985

Keywords

  • cataract extraction
  • intraocular lens calculation
  • intraocular lens implantation
  • penetrating keratoplasty
  • triple procedure

ASJC Scopus subject areas

  • Ophthalmology

Fingerprint Dive into the research topics of 'Intraocular Lens Calculation in Combined Penetrating Keratoplasty, Cataract Extraction and Intraocular Lens Implantation'. Together they form a unique fingerprint.