BACKGROUND: Central venous catheters (CVCs) increase the risk of venous thromboembolism. We have previously demonstrated that pulmonary artery catheters are associated with a hypercoagulable state in an animal model and in patients. The purpose of this study is to determine whether the insertion of a CVC is associated with a similar response. METHODS: Animal: 7F femoral artery catheters were placed in healthy anesthetized swine (N = 16). Serial arterial blood samples were drawn immediately before and after an 8.5F jugular vein CVC and then for 3 hours after CVC removal. Samples were analyzed using kaolin-activated thromboelastography (TEG) at precisely 2 minutes. Human: An institutional review board-approved prospective observational trial was conducted, with informed consent, in patients with critical illness (N = 8) at a Level I trauma center. Blood was drawn from indwelling arterial catheters immediately before and 60 minutes after CVC insertion. Samples were stored in sodium citrate for 15 minutes before TEG. Routine and special coagulation tests were performed on stored samples in the hospital pathology laboratory. RESULTS: Insertion of a CVC decreased TEG clotting time (R) by 55% in swine and by 29% in humans (p < 0.001 and 0.019, respectively). Initial clot formation time (K) was reduced by 41% in swine and by 36% in humans (p = 0003 and 0.019). Fibrin cross-linking (β±) was accelerated by 28% in swine and by 17% in humans (p = 0007 and 0.896), but overall clot strength (maximum amplitude) was not affected. There was no change in routine or special coagulation factors, including von Willebrand factor, antithrombin III, prothrombin time, international normalized ratio, or activated partial thromboplastin time. In animals, the hypercoagulable TEG response was persistent for 3 hours after CVC removal and was prevented by pretreatment with enoxaparin (n = 4) but not heparin (n = 2). CONCLUSION: In healthy swine and patients with critical illness, a systemic hypercoagulable state occurred after CVC insertion, and this may partially account for an increased risk of venous thromboembolism. However, because the sample size was small and not powered to detect changes in coagulation proteins, no inferences can be made about the mechanism for the hypercoagulable response.

Original languageEnglish
Pages (from-to)385-390
Number of pages6
JournalJournal of Trauma and Acute Care Surgery
Volume73
Issue number2
DOIs
StatePublished - Aug 1 2012

Fingerprint

Central Venous Catheters
Thrombelastography
Swine
Venous Thromboembolism
Critical Illness
Catheters
Kaolin
Enoxaparin
Hospital Laboratories
Indwelling Catheters
Blood Coagulation Factors
International Normalized Ratio
Antithrombin III
Partial Thromboplastin Time
Trauma Centers
Research Ethics Committees
Prothrombin Time
Jugular Veins
von Willebrand Factor
Femoral Artery

Keywords

  • deep venous thrombosis
  • thromboelastography
  • Venous thromboembolism

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine
  • Surgery

Cite this

Insertion of central venous catheters induces a hypercoagulable state. / Ryan, Mark L.; Thorson, Chad M.; King, David R.; Van Haren, Robert M.; Manning, Ronald J.; Andrews, David; Livingstone, Alan; Proctor, Kenneth G.

In: Journal of Trauma and Acute Care Surgery, Vol. 73, No. 2, 01.08.2012, p. 385-390.

Research output: Contribution to journalArticle

Ryan, Mark L. ; Thorson, Chad M. ; King, David R. ; Van Haren, Robert M. ; Manning, Ronald J. ; Andrews, David ; Livingstone, Alan ; Proctor, Kenneth G. / Insertion of central venous catheters induces a hypercoagulable state. In: Journal of Trauma and Acute Care Surgery. 2012 ; Vol. 73, No. 2. pp. 385-390.
@article{1aacf225292b404398ea656a803db15c,
title = "Insertion of central venous catheters induces a hypercoagulable state",
abstract = "BACKGROUND: Central venous catheters (CVCs) increase the risk of venous thromboembolism. We have previously demonstrated that pulmonary artery catheters are associated with a hypercoagulable state in an animal model and in patients. The purpose of this study is to determine whether the insertion of a CVC is associated with a similar response. METHODS: Animal: 7F femoral artery catheters were placed in healthy anesthetized swine (N = 16). Serial arterial blood samples were drawn immediately before and after an 8.5F jugular vein CVC and then for 3 hours after CVC removal. Samples were analyzed using kaolin-activated thromboelastography (TEG) at precisely 2 minutes. Human: An institutional review board-approved prospective observational trial was conducted, with informed consent, in patients with critical illness (N = 8) at a Level I trauma center. Blood was drawn from indwelling arterial catheters immediately before and 60 minutes after CVC insertion. Samples were stored in sodium citrate for 15 minutes before TEG. Routine and special coagulation tests were performed on stored samples in the hospital pathology laboratory. RESULTS: Insertion of a CVC decreased TEG clotting time (R) by 55{\%} in swine and by 29{\%} in humans (p < 0.001 and 0.019, respectively). Initial clot formation time (K) was reduced by 41{\%} in swine and by 36{\%} in humans (p = 0003 and 0.019). Fibrin cross-linking (β±) was accelerated by 28{\%} in swine and by 17{\%} in humans (p = 0007 and 0.896), but overall clot strength (maximum amplitude) was not affected. There was no change in routine or special coagulation factors, including von Willebrand factor, antithrombin III, prothrombin time, international normalized ratio, or activated partial thromboplastin time. In animals, the hypercoagulable TEG response was persistent for 3 hours after CVC removal and was prevented by pretreatment with enoxaparin (n = 4) but not heparin (n = 2). CONCLUSION: In healthy swine and patients with critical illness, a systemic hypercoagulable state occurred after CVC insertion, and this may partially account for an increased risk of venous thromboembolism. However, because the sample size was small and not powered to detect changes in coagulation proteins, no inferences can be made about the mechanism for the hypercoagulable response.",
keywords = "deep venous thrombosis, thromboelastography, Venous thromboembolism",
author = "Ryan, {Mark L.} and Thorson, {Chad M.} and King, {David R.} and {Van Haren}, {Robert M.} and Manning, {Ronald J.} and David Andrews and Alan Livingstone and Proctor, {Kenneth G}",
year = "2012",
month = "8",
day = "1",
doi = "10.1097/TA.0b013e31825a0519",
language = "English",
volume = "73",
pages = "385--390",
journal = "Journal of Trauma and Acute Care Surgery",
issn = "2163-0755",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Insertion of central venous catheters induces a hypercoagulable state

AU - Ryan, Mark L.

AU - Thorson, Chad M.

AU - King, David R.

AU - Van Haren, Robert M.

AU - Manning, Ronald J.

AU - Andrews, David

AU - Livingstone, Alan

AU - Proctor, Kenneth G

PY - 2012/8/1

Y1 - 2012/8/1

N2 - BACKGROUND: Central venous catheters (CVCs) increase the risk of venous thromboembolism. We have previously demonstrated that pulmonary artery catheters are associated with a hypercoagulable state in an animal model and in patients. The purpose of this study is to determine whether the insertion of a CVC is associated with a similar response. METHODS: Animal: 7F femoral artery catheters were placed in healthy anesthetized swine (N = 16). Serial arterial blood samples were drawn immediately before and after an 8.5F jugular vein CVC and then for 3 hours after CVC removal. Samples were analyzed using kaolin-activated thromboelastography (TEG) at precisely 2 minutes. Human: An institutional review board-approved prospective observational trial was conducted, with informed consent, in patients with critical illness (N = 8) at a Level I trauma center. Blood was drawn from indwelling arterial catheters immediately before and 60 minutes after CVC insertion. Samples were stored in sodium citrate for 15 minutes before TEG. Routine and special coagulation tests were performed on stored samples in the hospital pathology laboratory. RESULTS: Insertion of a CVC decreased TEG clotting time (R) by 55% in swine and by 29% in humans (p < 0.001 and 0.019, respectively). Initial clot formation time (K) was reduced by 41% in swine and by 36% in humans (p = 0003 and 0.019). Fibrin cross-linking (β±) was accelerated by 28% in swine and by 17% in humans (p = 0007 and 0.896), but overall clot strength (maximum amplitude) was not affected. There was no change in routine or special coagulation factors, including von Willebrand factor, antithrombin III, prothrombin time, international normalized ratio, or activated partial thromboplastin time. In animals, the hypercoagulable TEG response was persistent for 3 hours after CVC removal and was prevented by pretreatment with enoxaparin (n = 4) but not heparin (n = 2). CONCLUSION: In healthy swine and patients with critical illness, a systemic hypercoagulable state occurred after CVC insertion, and this may partially account for an increased risk of venous thromboembolism. However, because the sample size was small and not powered to detect changes in coagulation proteins, no inferences can be made about the mechanism for the hypercoagulable response.

AB - BACKGROUND: Central venous catheters (CVCs) increase the risk of venous thromboembolism. We have previously demonstrated that pulmonary artery catheters are associated with a hypercoagulable state in an animal model and in patients. The purpose of this study is to determine whether the insertion of a CVC is associated with a similar response. METHODS: Animal: 7F femoral artery catheters were placed in healthy anesthetized swine (N = 16). Serial arterial blood samples were drawn immediately before and after an 8.5F jugular vein CVC and then for 3 hours after CVC removal. Samples were analyzed using kaolin-activated thromboelastography (TEG) at precisely 2 minutes. Human: An institutional review board-approved prospective observational trial was conducted, with informed consent, in patients with critical illness (N = 8) at a Level I trauma center. Blood was drawn from indwelling arterial catheters immediately before and 60 minutes after CVC insertion. Samples were stored in sodium citrate for 15 minutes before TEG. Routine and special coagulation tests were performed on stored samples in the hospital pathology laboratory. RESULTS: Insertion of a CVC decreased TEG clotting time (R) by 55% in swine and by 29% in humans (p < 0.001 and 0.019, respectively). Initial clot formation time (K) was reduced by 41% in swine and by 36% in humans (p = 0003 and 0.019). Fibrin cross-linking (β±) was accelerated by 28% in swine and by 17% in humans (p = 0007 and 0.896), but overall clot strength (maximum amplitude) was not affected. There was no change in routine or special coagulation factors, including von Willebrand factor, antithrombin III, prothrombin time, international normalized ratio, or activated partial thromboplastin time. In animals, the hypercoagulable TEG response was persistent for 3 hours after CVC removal and was prevented by pretreatment with enoxaparin (n = 4) but not heparin (n = 2). CONCLUSION: In healthy swine and patients with critical illness, a systemic hypercoagulable state occurred after CVC insertion, and this may partially account for an increased risk of venous thromboembolism. However, because the sample size was small and not powered to detect changes in coagulation proteins, no inferences can be made about the mechanism for the hypercoagulable response.

KW - deep venous thrombosis

KW - thromboelastography

KW - Venous thromboembolism

UR - http://www.scopus.com/inward/record.url?scp=84864630521&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84864630521&partnerID=8YFLogxK

U2 - 10.1097/TA.0b013e31825a0519

DO - 10.1097/TA.0b013e31825a0519

M3 - Article

C2 - 22846944

AN - SCOPUS:84864630521

VL - 73

SP - 385

EP - 390

JO - Journal of Trauma and Acute Care Surgery

JF - Journal of Trauma and Acute Care Surgery

SN - 2163-0755

IS - 2

ER -