High-resolution electrical mapping of depolarization and repolarization alternans in an ischemic dog model

David Gordon, Alan H. Kadish, Daniel Koolish, Taresh Taneja, Joseph Ulphani, Jeffrey Goldberger, Jason Ng

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Cardiac electrical alternans have been associated with spontaneous ventricular arrhythmias during myocardial ischemia. The study aims were to use a new algorithm to measure depolarization and repolarization alternans from epicardial electrograms in an ischemia model and to evaluate which features are predictive of ventricular fibrillation (VF). The left anterior descending coronary artery was occluded in 21 dogs, of which 6 developed spontaneous VF. Four seconds of unipolar epicardial electrograms was recorded before and 5 min after occlusion from an 8 14-electrode plaque placed on the anterior left ventricle. Alternans amplitudes were estimated with a triangular wave-fitting algorithm and for each unipolar electrogram for various measurements of the QRS and ST-T wave amplitude. The root mean square error was computed for each fit. Receiver-operator characteristic curves were used to determine whether prevalence of alternans having estimated alternans amplitude-to-error ratio (A/E) above a given threshold could distinguish the dogs who had and did not have spontaneous VF. The prevalence of alternans after ischemia was highly predictive of VF when measured both during depolarization (sensitivity of 83% and specificity of 87%) and during repolarization (sensitivity of 100% and specificity of 73%). The optimal alternans A/E ranged from 1 to 4. There were no differences in the level of discordance or alternans amplitude between dogs who developed VF versus dogs who did not. The prevalence of alternans in the ventricles may be the key risk factor for developing VF during myocardial ischemia when short-term recordings are used.

Original languageEnglish (US)
JournalAmerican Journal of Physiology - Heart and Circulatory Physiology
Volume298
Issue number2
DOIs
StatePublished - Jan 29 2010
Externally publishedYes

Fingerprint

Ventricular Fibrillation
Dogs
Myocardial Ischemia
Ischemia
Sensitivity and Specificity
Heart Ventricles
Cardiac Arrhythmias
Coronary Vessels
Electrodes

Keywords

  • Myocardial ischemia
  • QRS alternans
  • ST-T wave alternans
  • Ventricular fibrillation

ASJC Scopus subject areas

  • Physiology
  • Physiology (medical)
  • Cardiology and Cardiovascular Medicine

Cite this

High-resolution electrical mapping of depolarization and repolarization alternans in an ischemic dog model. / Gordon, David; Kadish, Alan H.; Koolish, Daniel; Taneja, Taresh; Ulphani, Joseph; Goldberger, Jeffrey; Ng, Jason.

In: American Journal of Physiology - Heart and Circulatory Physiology, Vol. 298, No. 2, 29.01.2010.

Research output: Contribution to journalArticle

Gordon, David ; Kadish, Alan H. ; Koolish, Daniel ; Taneja, Taresh ; Ulphani, Joseph ; Goldberger, Jeffrey ; Ng, Jason. / High-resolution electrical mapping of depolarization and repolarization alternans in an ischemic dog model. In: American Journal of Physiology - Heart and Circulatory Physiology. 2010 ; Vol. 298, No. 2.
@article{213fb2723b254dbba792a5247fac33d8,
title = "High-resolution electrical mapping of depolarization and repolarization alternans in an ischemic dog model",
abstract = "Cardiac electrical alternans have been associated with spontaneous ventricular arrhythmias during myocardial ischemia. The study aims were to use a new algorithm to measure depolarization and repolarization alternans from epicardial electrograms in an ischemia model and to evaluate which features are predictive of ventricular fibrillation (VF). The left anterior descending coronary artery was occluded in 21 dogs, of which 6 developed spontaneous VF. Four seconds of unipolar epicardial electrograms was recorded before and 5 min after occlusion from an 8 14-electrode plaque placed on the anterior left ventricle. Alternans amplitudes were estimated with a triangular wave-fitting algorithm and for each unipolar electrogram for various measurements of the QRS and ST-T wave amplitude. The root mean square error was computed for each fit. Receiver-operator characteristic curves were used to determine whether prevalence of alternans having estimated alternans amplitude-to-error ratio (A/E) above a given threshold could distinguish the dogs who had and did not have spontaneous VF. The prevalence of alternans after ischemia was highly predictive of VF when measured both during depolarization (sensitivity of 83{\%} and specificity of 87{\%}) and during repolarization (sensitivity of 100{\%} and specificity of 73{\%}). The optimal alternans A/E ranged from 1 to 4. There were no differences in the level of discordance or alternans amplitude between dogs who developed VF versus dogs who did not. The prevalence of alternans in the ventricles may be the key risk factor for developing VF during myocardial ischemia when short-term recordings are used.",
keywords = "Myocardial ischemia, QRS alternans, ST-T wave alternans, Ventricular fibrillation",
author = "David Gordon and Kadish, {Alan H.} and Daniel Koolish and Taresh Taneja and Joseph Ulphani and Jeffrey Goldberger and Jason Ng",
year = "2010",
month = "1",
day = "29",
doi = "10.1152/ajpheart.00914.2009",
language = "English (US)",
volume = "298",
journal = "American Journal of Physiology - Cell Physiology",
issn = "0363-6143",
publisher = "American Physiological Society",
number = "2",

}

TY - JOUR

T1 - High-resolution electrical mapping of depolarization and repolarization alternans in an ischemic dog model

AU - Gordon, David

AU - Kadish, Alan H.

AU - Koolish, Daniel

AU - Taneja, Taresh

AU - Ulphani, Joseph

AU - Goldberger, Jeffrey

AU - Ng, Jason

PY - 2010/1/29

Y1 - 2010/1/29

N2 - Cardiac electrical alternans have been associated with spontaneous ventricular arrhythmias during myocardial ischemia. The study aims were to use a new algorithm to measure depolarization and repolarization alternans from epicardial electrograms in an ischemia model and to evaluate which features are predictive of ventricular fibrillation (VF). The left anterior descending coronary artery was occluded in 21 dogs, of which 6 developed spontaneous VF. Four seconds of unipolar epicardial electrograms was recorded before and 5 min after occlusion from an 8 14-electrode plaque placed on the anterior left ventricle. Alternans amplitudes were estimated with a triangular wave-fitting algorithm and for each unipolar electrogram for various measurements of the QRS and ST-T wave amplitude. The root mean square error was computed for each fit. Receiver-operator characteristic curves were used to determine whether prevalence of alternans having estimated alternans amplitude-to-error ratio (A/E) above a given threshold could distinguish the dogs who had and did not have spontaneous VF. The prevalence of alternans after ischemia was highly predictive of VF when measured both during depolarization (sensitivity of 83% and specificity of 87%) and during repolarization (sensitivity of 100% and specificity of 73%). The optimal alternans A/E ranged from 1 to 4. There were no differences in the level of discordance or alternans amplitude between dogs who developed VF versus dogs who did not. The prevalence of alternans in the ventricles may be the key risk factor for developing VF during myocardial ischemia when short-term recordings are used.

AB - Cardiac electrical alternans have been associated with spontaneous ventricular arrhythmias during myocardial ischemia. The study aims were to use a new algorithm to measure depolarization and repolarization alternans from epicardial electrograms in an ischemia model and to evaluate which features are predictive of ventricular fibrillation (VF). The left anterior descending coronary artery was occluded in 21 dogs, of which 6 developed spontaneous VF. Four seconds of unipolar epicardial electrograms was recorded before and 5 min after occlusion from an 8 14-electrode plaque placed on the anterior left ventricle. Alternans amplitudes were estimated with a triangular wave-fitting algorithm and for each unipolar electrogram for various measurements of the QRS and ST-T wave amplitude. The root mean square error was computed for each fit. Receiver-operator characteristic curves were used to determine whether prevalence of alternans having estimated alternans amplitude-to-error ratio (A/E) above a given threshold could distinguish the dogs who had and did not have spontaneous VF. The prevalence of alternans after ischemia was highly predictive of VF when measured both during depolarization (sensitivity of 83% and specificity of 87%) and during repolarization (sensitivity of 100% and specificity of 73%). The optimal alternans A/E ranged from 1 to 4. There were no differences in the level of discordance or alternans amplitude between dogs who developed VF versus dogs who did not. The prevalence of alternans in the ventricles may be the key risk factor for developing VF during myocardial ischemia when short-term recordings are used.

KW - Myocardial ischemia

KW - QRS alternans

KW - ST-T wave alternans

KW - Ventricular fibrillation

UR - http://www.scopus.com/inward/record.url?scp=74949103185&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=74949103185&partnerID=8YFLogxK

U2 - 10.1152/ajpheart.00914.2009

DO - 10.1152/ajpheart.00914.2009

M3 - Article

C2 - 19915171

AN - SCOPUS:74949103185

VL - 298

JO - American Journal of Physiology - Cell Physiology

JF - American Journal of Physiology - Cell Physiology

SN - 0363-6143

IS - 2

ER -