Global teleophthalmology with iPhones for real-time slitlamp eye examination

Yufeng Ye, Jianhua Wang, Yanan Xie, Jianguang Zhong, Yongpin Hu, Bin Chen, Xiaojian He, Huicheng Zhang

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

PURPOSE: To evaluate the image resolutions in global teleophthalmology using 2 smartphones.

METHODS: A standard resolution test card and two human eyes (one eye wearing a contact lens) were imaged with an iPhone 4S adapted for slitlamp biomicroscopy in Hangzhou, Zhejiang, China. An iPhone 5 was used as a receptor on the other side of the world (Miami, FL). The real-time images and still images were transferred through Skype from Hangzhou to Miami during slitlamp eye examination. The real-time resolutions captured and displayed on the both phones at different places were measured. There was vocal communication concurrent between two parties during image transference and the examination by the slitlamp biomicroscopy performed in Hangzhou.

RESULTS: The real-time and still images were transferred between two cities while two operators talked with each other smoothly and without difficulty. The viewer in Miami was able to instruct the operator in Hangzhou to thoroughly examine the eye using the slitlamp microscopy with different magnification settings and illumination settings. The resolution of the still images recorded in the iPhone in Hangzhou was higher than that of the real-time images on the screen. The main features of the eye were recognizable in real-time.

CONCLUSIONS: The study demonstrated that global teleophthalmology is feasible using two smartphones. The system is simple, portable, and affordable, and the image quality in still and real-time images is acceptable for real-time teleophthalmology.

Original languageEnglish (US)
Pages (from-to)297-300
Number of pages4
JournalEye & contact lens
Volume40
Issue number5
DOIs
StatePublished - Sep 1 2014

Fingerprint

Contact Lenses
Lighting
Microscopy
China
Communication
Smartphone
Transference (Psychology)

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Global teleophthalmology with iPhones for real-time slitlamp eye examination. / Ye, Yufeng; Wang, Jianhua; Xie, Yanan; Zhong, Jianguang; Hu, Yongpin; Chen, Bin; He, Xiaojian; Zhang, Huicheng.

In: Eye & contact lens, Vol. 40, No. 5, 01.09.2014, p. 297-300.

Research output: Contribution to journalArticle

Ye, Y, Wang, J, Xie, Y, Zhong, J, Hu, Y, Chen, B, He, X & Zhang, H 2014, 'Global teleophthalmology with iPhones for real-time slitlamp eye examination', Eye & contact lens, vol. 40, no. 5, pp. 297-300. https://doi.org/10.1097/ICL.0000000000000051
Ye, Yufeng ; Wang, Jianhua ; Xie, Yanan ; Zhong, Jianguang ; Hu, Yongpin ; Chen, Bin ; He, Xiaojian ; Zhang, Huicheng. / Global teleophthalmology with iPhones for real-time slitlamp eye examination. In: Eye & contact lens. 2014 ; Vol. 40, No. 5. pp. 297-300.
@article{e6879ed7c91149ed993f6da5028a5cdd,
title = "Global teleophthalmology with iPhones for real-time slitlamp eye examination",
abstract = "PURPOSE: To evaluate the image resolutions in global teleophthalmology using 2 smartphones.METHODS: A standard resolution test card and two human eyes (one eye wearing a contact lens) were imaged with an iPhone 4S adapted for slitlamp biomicroscopy in Hangzhou, Zhejiang, China. An iPhone 5 was used as a receptor on the other side of the world (Miami, FL). The real-time images and still images were transferred through Skype from Hangzhou to Miami during slitlamp eye examination. The real-time resolutions captured and displayed on the both phones at different places were measured. There was vocal communication concurrent between two parties during image transference and the examination by the slitlamp biomicroscopy performed in Hangzhou.RESULTS: The real-time and still images were transferred between two cities while two operators talked with each other smoothly and without difficulty. The viewer in Miami was able to instruct the operator in Hangzhou to thoroughly examine the eye using the slitlamp microscopy with different magnification settings and illumination settings. The resolution of the still images recorded in the iPhone in Hangzhou was higher than that of the real-time images on the screen. The main features of the eye were recognizable in real-time.CONCLUSIONS: The study demonstrated that global teleophthalmology is feasible using two smartphones. The system is simple, portable, and affordable, and the image quality in still and real-time images is acceptable for real-time teleophthalmology.",
author = "Yufeng Ye and Jianhua Wang and Yanan Xie and Jianguang Zhong and Yongpin Hu and Bin Chen and Xiaojian He and Huicheng Zhang",
year = "2014",
month = "9",
day = "1",
doi = "10.1097/ICL.0000000000000051",
language = "English (US)",
volume = "40",
pages = "297--300",
journal = "Eye and Contact Lense",
issn = "1542-2321",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - Global teleophthalmology with iPhones for real-time slitlamp eye examination

AU - Ye, Yufeng

AU - Wang, Jianhua

AU - Xie, Yanan

AU - Zhong, Jianguang

AU - Hu, Yongpin

AU - Chen, Bin

AU - He, Xiaojian

AU - Zhang, Huicheng

PY - 2014/9/1

Y1 - 2014/9/1

N2 - PURPOSE: To evaluate the image resolutions in global teleophthalmology using 2 smartphones.METHODS: A standard resolution test card and two human eyes (one eye wearing a contact lens) were imaged with an iPhone 4S adapted for slitlamp biomicroscopy in Hangzhou, Zhejiang, China. An iPhone 5 was used as a receptor on the other side of the world (Miami, FL). The real-time images and still images were transferred through Skype from Hangzhou to Miami during slitlamp eye examination. The real-time resolutions captured and displayed on the both phones at different places were measured. There was vocal communication concurrent between two parties during image transference and the examination by the slitlamp biomicroscopy performed in Hangzhou.RESULTS: The real-time and still images were transferred between two cities while two operators talked with each other smoothly and without difficulty. The viewer in Miami was able to instruct the operator in Hangzhou to thoroughly examine the eye using the slitlamp microscopy with different magnification settings and illumination settings. The resolution of the still images recorded in the iPhone in Hangzhou was higher than that of the real-time images on the screen. The main features of the eye were recognizable in real-time.CONCLUSIONS: The study demonstrated that global teleophthalmology is feasible using two smartphones. The system is simple, portable, and affordable, and the image quality in still and real-time images is acceptable for real-time teleophthalmology.

AB - PURPOSE: To evaluate the image resolutions in global teleophthalmology using 2 smartphones.METHODS: A standard resolution test card and two human eyes (one eye wearing a contact lens) were imaged with an iPhone 4S adapted for slitlamp biomicroscopy in Hangzhou, Zhejiang, China. An iPhone 5 was used as a receptor on the other side of the world (Miami, FL). The real-time images and still images were transferred through Skype from Hangzhou to Miami during slitlamp eye examination. The real-time resolutions captured and displayed on the both phones at different places were measured. There was vocal communication concurrent between two parties during image transference and the examination by the slitlamp biomicroscopy performed in Hangzhou.RESULTS: The real-time and still images were transferred between two cities while two operators talked with each other smoothly and without difficulty. The viewer in Miami was able to instruct the operator in Hangzhou to thoroughly examine the eye using the slitlamp microscopy with different magnification settings and illumination settings. The resolution of the still images recorded in the iPhone in Hangzhou was higher than that of the real-time images on the screen. The main features of the eye were recognizable in real-time.CONCLUSIONS: The study demonstrated that global teleophthalmology is feasible using two smartphones. The system is simple, portable, and affordable, and the image quality in still and real-time images is acceptable for real-time teleophthalmology.

UR - http://www.scopus.com/inward/record.url?scp=85027924867&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85027924867&partnerID=8YFLogxK

U2 - 10.1097/ICL.0000000000000051

DO - 10.1097/ICL.0000000000000051

M3 - Article

C2 - 25083779

AN - SCOPUS:85027924867

VL - 40

SP - 297

EP - 300

JO - Eye and Contact Lense

JF - Eye and Contact Lense

SN - 1542-2321

IS - 5

ER -