Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma

Basil K. Williams, Amy C. Schefler, Scott N. Garonzik, Daniel Gologorsky, Wei Shi, Ludimila L. Cavalcante, Milena L. Cavalcante, William J Feuer, Timothy G. Murray

Research output: Contribution to journalArticle

Abstract

PURPOSE: To examine the effects of prosthesis refitting on porous orbital implant exposure in 100 patients who underwent enucleation for retinoblastoma.

METHODS: Parameters analyzed included patient's age at enucleation, gender, implant type, frequency of prosthesis adjustment, and use of chemotherapy or radiation. The main outcome measures consisted of the condition of the fornices, condition of the implant (including conjunctival thinning), and condition and functioning ability of the prosthesis.

RESULTS: Increased frequency of visits with the ocularist and number of prosthesis adjustments and refits significantly improved the condition of the implant, fornices, and prosthesis. The patient's age at enucleation, gender, and use of chemotherapy or radiation did not have a significant effect on any of the outcome variables. The condition of the implant was significantly better for porous polyethylene than hydroxyapatite implants (P = .024). No implant exposures were observed.

CONCLUSION: Frequent adjustments and refits by the ocularist are significantly associated with a reduced rate of conjunctival thinning and complete avoidance of implant exposure in patients undergoing enucleation for retinoblastoma. These findings are particularly significant for this population, which historically has demonstrated a high rate of implant exposure.

Original languageEnglish (US)
Pages (from-to)238-246
Number of pages9
JournalJournal of Pediatric Ophthalmology and Strabismus
Volume48
Issue number4
DOIs
StatePublished - Jul 1 2011
Externally publishedYes

Fingerprint

Retinoblastoma
Prostheses and Implants
Prosthesis Fitting
Orbital Implants
Radiation
Drug Therapy
Polyethylene
Durapatite
Outcome Assessment (Health Care)
Population

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Williams, B. K., Schefler, A. C., Garonzik, S. N., Gologorsky, D., Shi, W., Cavalcante, L. L., ... Murray, T. G. (2011). Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma. Journal of Pediatric Ophthalmology and Strabismus, 48(4), 238-246. https://doi.org/10.3928/01913913-20100818-06

Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma. / Williams, Basil K.; Schefler, Amy C.; Garonzik, Scott N.; Gologorsky, Daniel; Shi, Wei; Cavalcante, Ludimila L.; Cavalcante, Milena L.; Feuer, William J; Murray, Timothy G.

In: Journal of Pediatric Ophthalmology and Strabismus, Vol. 48, No. 4, 01.07.2011, p. 238-246.

Research output: Contribution to journalArticle

Williams, BK, Schefler, AC, Garonzik, SN, Gologorsky, D, Shi, W, Cavalcante, LL, Cavalcante, ML, Feuer, WJ & Murray, TG 2011, 'Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma', Journal of Pediatric Ophthalmology and Strabismus, vol. 48, no. 4, pp. 238-246. https://doi.org/10.3928/01913913-20100818-06
Williams, Basil K. ; Schefler, Amy C. ; Garonzik, Scott N. ; Gologorsky, Daniel ; Shi, Wei ; Cavalcante, Ludimila L. ; Cavalcante, Milena L. ; Feuer, William J ; Murray, Timothy G. / Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma. In: Journal of Pediatric Ophthalmology and Strabismus. 2011 ; Vol. 48, No. 4. pp. 238-246.
@article{49700d9ede624cd88c78643b0f77fe75,
title = "Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma",
abstract = "PURPOSE: To examine the effects of prosthesis refitting on porous orbital implant exposure in 100 patients who underwent enucleation for retinoblastoma.METHODS: Parameters analyzed included patient's age at enucleation, gender, implant type, frequency of prosthesis adjustment, and use of chemotherapy or radiation. The main outcome measures consisted of the condition of the fornices, condition of the implant (including conjunctival thinning), and condition and functioning ability of the prosthesis.RESULTS: Increased frequency of visits with the ocularist and number of prosthesis adjustments and refits significantly improved the condition of the implant, fornices, and prosthesis. The patient's age at enucleation, gender, and use of chemotherapy or radiation did not have a significant effect on any of the outcome variables. The condition of the implant was significantly better for porous polyethylene than hydroxyapatite implants (P = .024). No implant exposures were observed.CONCLUSION: Frequent adjustments and refits by the ocularist are significantly associated with a reduced rate of conjunctival thinning and complete avoidance of implant exposure in patients undergoing enucleation for retinoblastoma. These findings are particularly significant for this population, which historically has demonstrated a high rate of implant exposure.",
author = "Williams, {Basil K.} and Schefler, {Amy C.} and Garonzik, {Scott N.} and Daniel Gologorsky and Wei Shi and Cavalcante, {Ludimila L.} and Cavalcante, {Milena L.} and Feuer, {William J} and Murray, {Timothy G.}",
year = "2011",
month = "7",
day = "1",
doi = "10.3928/01913913-20100818-06",
language = "English (US)",
volume = "48",
pages = "238--246",
journal = "Journal of Pediatric Ophthalmology and Strabismus",
issn = "0191-3913",
publisher = "Slack Incorporated",
number = "4",

}

TY - JOUR

T1 - Frequent prosthesis refitting to prevent implant exposure in patients with retinoblastoma

AU - Williams, Basil K.

AU - Schefler, Amy C.

AU - Garonzik, Scott N.

AU - Gologorsky, Daniel

AU - Shi, Wei

AU - Cavalcante, Ludimila L.

AU - Cavalcante, Milena L.

AU - Feuer, William J

AU - Murray, Timothy G.

PY - 2011/7/1

Y1 - 2011/7/1

N2 - PURPOSE: To examine the effects of prosthesis refitting on porous orbital implant exposure in 100 patients who underwent enucleation for retinoblastoma.METHODS: Parameters analyzed included patient's age at enucleation, gender, implant type, frequency of prosthesis adjustment, and use of chemotherapy or radiation. The main outcome measures consisted of the condition of the fornices, condition of the implant (including conjunctival thinning), and condition and functioning ability of the prosthesis.RESULTS: Increased frequency of visits with the ocularist and number of prosthesis adjustments and refits significantly improved the condition of the implant, fornices, and prosthesis. The patient's age at enucleation, gender, and use of chemotherapy or radiation did not have a significant effect on any of the outcome variables. The condition of the implant was significantly better for porous polyethylene than hydroxyapatite implants (P = .024). No implant exposures were observed.CONCLUSION: Frequent adjustments and refits by the ocularist are significantly associated with a reduced rate of conjunctival thinning and complete avoidance of implant exposure in patients undergoing enucleation for retinoblastoma. These findings are particularly significant for this population, which historically has demonstrated a high rate of implant exposure.

AB - PURPOSE: To examine the effects of prosthesis refitting on porous orbital implant exposure in 100 patients who underwent enucleation for retinoblastoma.METHODS: Parameters analyzed included patient's age at enucleation, gender, implant type, frequency of prosthesis adjustment, and use of chemotherapy or radiation. The main outcome measures consisted of the condition of the fornices, condition of the implant (including conjunctival thinning), and condition and functioning ability of the prosthesis.RESULTS: Increased frequency of visits with the ocularist and number of prosthesis adjustments and refits significantly improved the condition of the implant, fornices, and prosthesis. The patient's age at enucleation, gender, and use of chemotherapy or radiation did not have a significant effect on any of the outcome variables. The condition of the implant was significantly better for porous polyethylene than hydroxyapatite implants (P = .024). No implant exposures were observed.CONCLUSION: Frequent adjustments and refits by the ocularist are significantly associated with a reduced rate of conjunctival thinning and complete avoidance of implant exposure in patients undergoing enucleation for retinoblastoma. These findings are particularly significant for this population, which historically has demonstrated a high rate of implant exposure.

UR - http://www.scopus.com/inward/record.url?scp=84964988299&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84964988299&partnerID=8YFLogxK

U2 - 10.3928/01913913-20100818-06

DO - 10.3928/01913913-20100818-06

M3 - Article

C2 - 20795600

AN - SCOPUS:84964988299

VL - 48

SP - 238

EP - 246

JO - Journal of Pediatric Ophthalmology and Strabismus

JF - Journal of Pediatric Ophthalmology and Strabismus

SN - 0191-3913

IS - 4

ER -