Experimental study of kinematic focusing. Comparison of electroinjection and sequential injection determination of copper

Victor P. Andreev, Natalia B. Ilyina, David A. Holman, Louis D. Scampavia, Gary D. Christian

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

The recently predicted phenomenon of kinematic focusing was studied experimentally using copper ions and EDTA as reactants. Kinematic focusing occurs, in electroinjection analysis, when the detected reaction product moves at the same rate as the reagent present in excess. Thus, reaction product accumulates without dispersion at the front of the excess reagent. Cu-EDTA2- complex was observed at 254 nm to form an exceptionally sharp peak as the front of the EDTA zone passed by the detector. The concentrating effect of kinematic focusing was quantified by electroinjection of premixed Cu-EDTA2-. Sensitivity was compared to that of sequential injection analysis using a 1 cm optical pathlength. Sensitivity was highest in the electroinjection mode, in spite of its 120 μm capillary pathlength, due to kinematic focusing.

Original languageEnglish
Pages (from-to)485-490
Number of pages6
JournalTalanta
Volume48
Issue number2
DOIs
StatePublished - Feb 1 1999

Fingerprint

Biomechanical Phenomena
Copper
Kinematics
Injections
Reaction products
Edetic Acid
Ions
Detectors

Keywords

  • Electroinjection
  • Kinematic focusing
  • Sequential injection

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Experimental study of kinematic focusing. Comparison of electroinjection and sequential injection determination of copper. / Andreev, Victor P.; Ilyina, Natalia B.; Holman, David A.; Scampavia, Louis D.; Christian, Gary D.

In: Talanta, Vol. 48, No. 2, 01.02.1999, p. 485-490.

Research output: Contribution to journalArticle

Andreev, Victor P. ; Ilyina, Natalia B. ; Holman, David A. ; Scampavia, Louis D. ; Christian, Gary D. / Experimental study of kinematic focusing. Comparison of electroinjection and sequential injection determination of copper. In: Talanta. 1999 ; Vol. 48, No. 2. pp. 485-490.
@article{70edf7fd4e0f455089c7dbbfdc2382a6,
title = "Experimental study of kinematic focusing. Comparison of electroinjection and sequential injection determination of copper",
abstract = "The recently predicted phenomenon of kinematic focusing was studied experimentally using copper ions and EDTA as reactants. Kinematic focusing occurs, in electroinjection analysis, when the detected reaction product moves at the same rate as the reagent present in excess. Thus, reaction product accumulates without dispersion at the front of the excess reagent. Cu-EDTA2- complex was observed at 254 nm to form an exceptionally sharp peak as the front of the EDTA zone passed by the detector. The concentrating effect of kinematic focusing was quantified by electroinjection of premixed Cu-EDTA2-. Sensitivity was compared to that of sequential injection analysis using a 1 cm optical pathlength. Sensitivity was highest in the electroinjection mode, in spite of its 120 μm capillary pathlength, due to kinematic focusing.",
keywords = "Electroinjection, Kinematic focusing, Sequential injection",
author = "Andreev, {Victor P.} and Ilyina, {Natalia B.} and Holman, {David A.} and Scampavia, {Louis D.} and Christian, {Gary D.}",
year = "1999",
month = "2",
day = "1",
doi = "10.1016/S0039-9140(98)00270-7",
language = "English",
volume = "48",
pages = "485--490",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Experimental study of kinematic focusing. Comparison of electroinjection and sequential injection determination of copper

AU - Andreev, Victor P.

AU - Ilyina, Natalia B.

AU - Holman, David A.

AU - Scampavia, Louis D.

AU - Christian, Gary D.

PY - 1999/2/1

Y1 - 1999/2/1

N2 - The recently predicted phenomenon of kinematic focusing was studied experimentally using copper ions and EDTA as reactants. Kinematic focusing occurs, in electroinjection analysis, when the detected reaction product moves at the same rate as the reagent present in excess. Thus, reaction product accumulates without dispersion at the front of the excess reagent. Cu-EDTA2- complex was observed at 254 nm to form an exceptionally sharp peak as the front of the EDTA zone passed by the detector. The concentrating effect of kinematic focusing was quantified by electroinjection of premixed Cu-EDTA2-. Sensitivity was compared to that of sequential injection analysis using a 1 cm optical pathlength. Sensitivity was highest in the electroinjection mode, in spite of its 120 μm capillary pathlength, due to kinematic focusing.

AB - The recently predicted phenomenon of kinematic focusing was studied experimentally using copper ions and EDTA as reactants. Kinematic focusing occurs, in electroinjection analysis, when the detected reaction product moves at the same rate as the reagent present in excess. Thus, reaction product accumulates without dispersion at the front of the excess reagent. Cu-EDTA2- complex was observed at 254 nm to form an exceptionally sharp peak as the front of the EDTA zone passed by the detector. The concentrating effect of kinematic focusing was quantified by electroinjection of premixed Cu-EDTA2-. Sensitivity was compared to that of sequential injection analysis using a 1 cm optical pathlength. Sensitivity was highest in the electroinjection mode, in spite of its 120 μm capillary pathlength, due to kinematic focusing.

KW - Electroinjection

KW - Kinematic focusing

KW - Sequential injection

UR - http://www.scopus.com/inward/record.url?scp=0032906226&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032906226&partnerID=8YFLogxK

U2 - 10.1016/S0039-9140(98)00270-7

DO - 10.1016/S0039-9140(98)00270-7

M3 - Article

VL - 48

SP - 485

EP - 490

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 2

ER -