End-point energy and half-life of the [Formula Presented] decay

Massimiliano Galeazzi, F. Fontanelli, F. Gatti, S. Vitale

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

A high statistics measurement of the β decay of [Formula Presented] with a cryogenic microcalorimeter has been performed. The high accuracy and the calorimetric nature of the measurement allow setting a value for the end-point energy of the decay in a metallic rhenium crystal equal to [Formula Presented] eV. A good extrapolation of the spectrum to zero energy has also been possible thanks to the stable and well determined detector response down to the energy threshold of about 420 eV. This allows an estimate of the [Formula Presented] half-life of [Formula Presented] Both results are significantly better than the previous measurements reported in the literature.

Original languageEnglish (US)
Number of pages1
JournalPhysical Review C - Nuclear Physics
Volume63
Issue number1
DOIs
StatePublished - Jan 1 2001
Externally publishedYes

Fingerprint

half life
decay
energy
rhenium
cryogenics
calorimeters
extrapolation
statistics
thresholds
detectors
estimates
crystals

ASJC Scopus subject areas

  • Nuclear and High Energy Physics

Cite this

End-point energy and half-life of the [Formula Presented] decay. / Galeazzi, Massimiliano; Fontanelli, F.; Gatti, F.; Vitale, S.

In: Physical Review C - Nuclear Physics, Vol. 63, No. 1, 01.01.2001.

Research output: Contribution to journalArticle

@article{29ac57cddc8746a8bfc3f009011fb439,
title = "End-point energy and half-life of the [Formula Presented] decay",
abstract = "A high statistics measurement of the β decay of [Formula Presented] with a cryogenic microcalorimeter has been performed. The high accuracy and the calorimetric nature of the measurement allow setting a value for the end-point energy of the decay in a metallic rhenium crystal equal to [Formula Presented] eV. A good extrapolation of the spectrum to zero energy has also been possible thanks to the stable and well determined detector response down to the energy threshold of about 420 eV. This allows an estimate of the [Formula Presented] half-life of [Formula Presented] Both results are significantly better than the previous measurements reported in the literature.",
author = "Massimiliano Galeazzi and F. Fontanelli and F. Gatti and S. Vitale",
year = "2001",
month = "1",
day = "1",
doi = "10.1103/PhysRevC.63.014302",
language = "English (US)",
volume = "63",
journal = "Physical Review C - Nuclear Physics",
issn = "0556-2813",
publisher = "American Physical Society",
number = "1",

}

TY - JOUR

T1 - End-point energy and half-life of the [Formula Presented] decay

AU - Galeazzi, Massimiliano

AU - Fontanelli, F.

AU - Gatti, F.

AU - Vitale, S.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - A high statistics measurement of the β decay of [Formula Presented] with a cryogenic microcalorimeter has been performed. The high accuracy and the calorimetric nature of the measurement allow setting a value for the end-point energy of the decay in a metallic rhenium crystal equal to [Formula Presented] eV. A good extrapolation of the spectrum to zero energy has also been possible thanks to the stable and well determined detector response down to the energy threshold of about 420 eV. This allows an estimate of the [Formula Presented] half-life of [Formula Presented] Both results are significantly better than the previous measurements reported in the literature.

AB - A high statistics measurement of the β decay of [Formula Presented] with a cryogenic microcalorimeter has been performed. The high accuracy and the calorimetric nature of the measurement allow setting a value for the end-point energy of the decay in a metallic rhenium crystal equal to [Formula Presented] eV. A good extrapolation of the spectrum to zero energy has also been possible thanks to the stable and well determined detector response down to the energy threshold of about 420 eV. This allows an estimate of the [Formula Presented] half-life of [Formula Presented] Both results are significantly better than the previous measurements reported in the literature.

UR - http://www.scopus.com/inward/record.url?scp=85035301626&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85035301626&partnerID=8YFLogxK

U2 - 10.1103/PhysRevC.63.014302

DO - 10.1103/PhysRevC.63.014302

M3 - Article

VL - 63

JO - Physical Review C - Nuclear Physics

JF - Physical Review C - Nuclear Physics

SN - 0556-2813

IS - 1