Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications

Alexandra Damley-Strnad, Brigitte Morales, Charles Ellis, Landon R Grace

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The relationship between pressure-sensing capability, carbon black (CB) content, and tensile strength of a CB-reinforced poly(styrene-isobutylene-styrene) (SIBS) thermoplastic elastomer was investigated. Inexpensive pressure sensors have excellent potential in both implantable and external (stick-to-skin) biomedical applications. Due to its excellent biocompatibility and commercial use in biomedical implants, SIBS is an excellent host material for the conductive CB reinforcement. Applications include stickto-skin sensors to supplement peripheral nerve function for anesthetized patients, stroke victims, or diabetic patients suffering from peripheral neuropathy. Five specimens ranging from 0% to 25% CB content by weight were fabricated through a combination of high-shear mixing, ultrasonication, and solvent casting. Electrical properties were explored using a custom-built apparatus capable of measuring resistance as a function of applied pressure. Results indicated that the 15% CB specimen performed significantly better than other loading percentages; it produced the largest variability in resistivity within the studied pressure range, along with a 13% increase in tensile strength. A direct relationship between pressure sensitivity (resistivity range) and tensile strength appears to exist in specimens near or at the percolation threshold, whereas otherwise, an inverse relationship is present. This initial research represents a step toward understanding interactions between the competing design goals of CB content, mechanical strength, and retained biocompatibility. The results of the 15% CB specimens show particular promise, as pressure sensitivity was maximized without sacrificing tensile strength. Further, initial results showed no sign of toxicity from SIBS/CB on human stem cells after a seven-day incubation period. In conclusion, these results support the potential use of SIBS/CB composites in biomedical sensing applications without sacrificing tensile strength or biocompatibility.

Original languageEnglish (US)
Title of host publication32nd Technical Conference of the American Society for Composites 2017
PublisherDEStech Publications Inc.
Pages1875-1889
Number of pages15
Volume3
ISBN (Electronic)9781510853065
StatePublished - Jan 1 2017
Externally publishedYes
Event32nd Technical Conference of the American Society for Composites 2017 - West Lafayette, United States
Duration: Oct 23 2017Oct 25 2017

Other

Other32nd Technical Conference of the American Society for Composites 2017
CountryUnited States
CityWest Lafayette
Period10/23/1710/25/17

Fingerprint

Soot
Thermoplastic elastomers
Styrene
Carbon black
Electric properties
Mechanical properties
Tensile strength
Biocompatibility
Skin
Pressure sensors
Stem cells
Strength of materials
Toxicity
Reinforcement
Casting

ASJC Scopus subject areas

  • Ceramics and Composites

Cite this

Damley-Strnad, A., Morales, B., Ellis, C., & Grace, L. R. (2017). Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications. In 32nd Technical Conference of the American Society for Composites 2017 (Vol. 3, pp. 1875-1889). DEStech Publications Inc..

Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications. / Damley-Strnad, Alexandra; Morales, Brigitte; Ellis, Charles; Grace, Landon R.

32nd Technical Conference of the American Society for Composites 2017. Vol. 3 DEStech Publications Inc., 2017. p. 1875-1889.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Damley-Strnad, A, Morales, B, Ellis, C & Grace, LR 2017, Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications. in 32nd Technical Conference of the American Society for Composites 2017. vol. 3, DEStech Publications Inc., pp. 1875-1889, 32nd Technical Conference of the American Society for Composites 2017, West Lafayette, United States, 10/23/17.
Damley-Strnad A, Morales B, Ellis C, Grace LR. Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications. In 32nd Technical Conference of the American Society for Composites 2017. Vol. 3. DEStech Publications Inc. 2017. p. 1875-1889
Damley-Strnad, Alexandra ; Morales, Brigitte ; Ellis, Charles ; Grace, Landon R. / Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications. 32nd Technical Conference of the American Society for Composites 2017. Vol. 3 DEStech Publications Inc., 2017. pp. 1875-1889
@inproceedings{0f4950b4b81645e3999d7f9f62156f2d,
title = "Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications",
abstract = "The relationship between pressure-sensing capability, carbon black (CB) content, and tensile strength of a CB-reinforced poly(styrene-isobutylene-styrene) (SIBS) thermoplastic elastomer was investigated. Inexpensive pressure sensors have excellent potential in both implantable and external (stick-to-skin) biomedical applications. Due to its excellent biocompatibility and commercial use in biomedical implants, SIBS is an excellent host material for the conductive CB reinforcement. Applications include stickto-skin sensors to supplement peripheral nerve function for anesthetized patients, stroke victims, or diabetic patients suffering from peripheral neuropathy. Five specimens ranging from 0{\%} to 25{\%} CB content by weight were fabricated through a combination of high-shear mixing, ultrasonication, and solvent casting. Electrical properties were explored using a custom-built apparatus capable of measuring resistance as a function of applied pressure. Results indicated that the 15{\%} CB specimen performed significantly better than other loading percentages; it produced the largest variability in resistivity within the studied pressure range, along with a 13{\%} increase in tensile strength. A direct relationship between pressure sensitivity (resistivity range) and tensile strength appears to exist in specimens near or at the percolation threshold, whereas otherwise, an inverse relationship is present. This initial research represents a step toward understanding interactions between the competing design goals of CB content, mechanical strength, and retained biocompatibility. The results of the 15{\%} CB specimens show particular promise, as pressure sensitivity was maximized without sacrificing tensile strength. Further, initial results showed no sign of toxicity from SIBS/CB on human stem cells after a seven-day incubation period. In conclusion, these results support the potential use of SIBS/CB composites in biomedical sensing applications without sacrificing tensile strength or biocompatibility.",
author = "Alexandra Damley-Strnad and Brigitte Morales and Charles Ellis and Grace, {Landon R}",
year = "2017",
month = "1",
day = "1",
language = "English (US)",
volume = "3",
pages = "1875--1889",
booktitle = "32nd Technical Conference of the American Society for Composites 2017",
publisher = "DEStech Publications Inc.",
address = "United States",

}

TY - GEN

T1 - Electrical and mechanical properties of a biocompatible carbon black reinforced thermoplastic elastomer for sensing applications

AU - Damley-Strnad, Alexandra

AU - Morales, Brigitte

AU - Ellis, Charles

AU - Grace, Landon R

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The relationship between pressure-sensing capability, carbon black (CB) content, and tensile strength of a CB-reinforced poly(styrene-isobutylene-styrene) (SIBS) thermoplastic elastomer was investigated. Inexpensive pressure sensors have excellent potential in both implantable and external (stick-to-skin) biomedical applications. Due to its excellent biocompatibility and commercial use in biomedical implants, SIBS is an excellent host material for the conductive CB reinforcement. Applications include stickto-skin sensors to supplement peripheral nerve function for anesthetized patients, stroke victims, or diabetic patients suffering from peripheral neuropathy. Five specimens ranging from 0% to 25% CB content by weight were fabricated through a combination of high-shear mixing, ultrasonication, and solvent casting. Electrical properties were explored using a custom-built apparatus capable of measuring resistance as a function of applied pressure. Results indicated that the 15% CB specimen performed significantly better than other loading percentages; it produced the largest variability in resistivity within the studied pressure range, along with a 13% increase in tensile strength. A direct relationship between pressure sensitivity (resistivity range) and tensile strength appears to exist in specimens near or at the percolation threshold, whereas otherwise, an inverse relationship is present. This initial research represents a step toward understanding interactions between the competing design goals of CB content, mechanical strength, and retained biocompatibility. The results of the 15% CB specimens show particular promise, as pressure sensitivity was maximized without sacrificing tensile strength. Further, initial results showed no sign of toxicity from SIBS/CB on human stem cells after a seven-day incubation period. In conclusion, these results support the potential use of SIBS/CB composites in biomedical sensing applications without sacrificing tensile strength or biocompatibility.

AB - The relationship between pressure-sensing capability, carbon black (CB) content, and tensile strength of a CB-reinforced poly(styrene-isobutylene-styrene) (SIBS) thermoplastic elastomer was investigated. Inexpensive pressure sensors have excellent potential in both implantable and external (stick-to-skin) biomedical applications. Due to its excellent biocompatibility and commercial use in biomedical implants, SIBS is an excellent host material for the conductive CB reinforcement. Applications include stickto-skin sensors to supplement peripheral nerve function for anesthetized patients, stroke victims, or diabetic patients suffering from peripheral neuropathy. Five specimens ranging from 0% to 25% CB content by weight were fabricated through a combination of high-shear mixing, ultrasonication, and solvent casting. Electrical properties were explored using a custom-built apparatus capable of measuring resistance as a function of applied pressure. Results indicated that the 15% CB specimen performed significantly better than other loading percentages; it produced the largest variability in resistivity within the studied pressure range, along with a 13% increase in tensile strength. A direct relationship between pressure sensitivity (resistivity range) and tensile strength appears to exist in specimens near or at the percolation threshold, whereas otherwise, an inverse relationship is present. This initial research represents a step toward understanding interactions between the competing design goals of CB content, mechanical strength, and retained biocompatibility. The results of the 15% CB specimens show particular promise, as pressure sensitivity was maximized without sacrificing tensile strength. Further, initial results showed no sign of toxicity from SIBS/CB on human stem cells after a seven-day incubation period. In conclusion, these results support the potential use of SIBS/CB composites in biomedical sensing applications without sacrificing tensile strength or biocompatibility.

UR - http://www.scopus.com/inward/record.url?scp=85047721301&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85047721301&partnerID=8YFLogxK

M3 - Conference contribution

VL - 3

SP - 1875

EP - 1889

BT - 32nd Technical Conference of the American Society for Composites 2017

PB - DEStech Publications Inc.

ER -