Effectiveness of compensating filters in the presence of tissue inhomogeneities.

A. Sethi, L. Leybovich, Nesrin Dogan, G. Glasgow

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

CT based 3D treatment planning systems (3DTPS) can be used to design compensating filters that, in addition to missing tissue compensation, can account for tissue inhomogeneities. The use of computer-driven systems provides a practical, convenient, and accurate method of fabricating compensating filters. In this work, we have evaluated a commercially available PAR Scientific DIGIMILL milling machine linked with FOCUS 3DTPS. Compensating filters were fabricated using refined gypsum material with no additives. Thus, filters were of manageable dimensions and were not sensitive to common machining errors. Compensating filters were evaluated using a homogeneous step phantom and step phantoms containing various internal inhomogeneities (air, cork, and bone). The accuracy of two planning algorithms used to design filters was experimentally evaluated. The superposition algorithm was found to produce better agreement with measurements than the Clarkson algorithm. Phantom measurements have demonstrated that compensating filters were able to produce a uniform dose distribution along the compensation plane in the presence of tissue inhomogeneity. However, the dose variation was greatly amplified in planes located beyond the inhomogeneity when a single compensated beam was used. The use of parallel-opposed compensated beams eliminated this problem. Both lateral and depth-dose uniformity was achieved throughout the target volume. (c) 2003 American College of Medical Physics.

Original languageEnglish (US)
Pages (from-to)209-216
Number of pages8
JournalJournal of applied clinical medical physics / American College of Medical Physics
Volume4
Issue number3
DOIs
StatePublished - Jan 1 2003
Externally publishedYes

Fingerprint

inhomogeneity
Tissue
filters
Planning
Calcium Sulfate
Milling machines
planning
Physics
Gypsum
Computer Systems
Machining
Bone
dosage
Computer systems
Air
Bone and Bones
milling machines
gypsum
machining
bones

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Cite this

Effectiveness of compensating filters in the presence of tissue inhomogeneities. / Sethi, A.; Leybovich, L.; Dogan, Nesrin; Glasgow, G.

In: Journal of applied clinical medical physics / American College of Medical Physics, Vol. 4, No. 3, 01.01.2003, p. 209-216.

Research output: Contribution to journalArticle

@article{c0416fb732be41f6acce8bc98bdad74c,
title = "Effectiveness of compensating filters in the presence of tissue inhomogeneities.",
abstract = "CT based 3D treatment planning systems (3DTPS) can be used to design compensating filters that, in addition to missing tissue compensation, can account for tissue inhomogeneities. The use of computer-driven systems provides a practical, convenient, and accurate method of fabricating compensating filters. In this work, we have evaluated a commercially available PAR Scientific DIGIMILL milling machine linked with FOCUS 3DTPS. Compensating filters were fabricated using refined gypsum material with no additives. Thus, filters were of manageable dimensions and were not sensitive to common machining errors. Compensating filters were evaluated using a homogeneous step phantom and step phantoms containing various internal inhomogeneities (air, cork, and bone). The accuracy of two planning algorithms used to design filters was experimentally evaluated. The superposition algorithm was found to produce better agreement with measurements than the Clarkson algorithm. Phantom measurements have demonstrated that compensating filters were able to produce a uniform dose distribution along the compensation plane in the presence of tissue inhomogeneity. However, the dose variation was greatly amplified in planes located beyond the inhomogeneity when a single compensated beam was used. The use of parallel-opposed compensated beams eliminated this problem. Both lateral and depth-dose uniformity was achieved throughout the target volume. (c) 2003 American College of Medical Physics.",
author = "A. Sethi and L. Leybovich and Nesrin Dogan and G. Glasgow",
year = "2003",
month = "1",
day = "1",
doi = "10.1120/jacmp.v4i3.2517",
language = "English (US)",
volume = "4",
pages = "209--216",
journal = "Journal of applied clinical medical physics / American College of Medical Physics",
issn = "1526-9914",
publisher = "American Institute of Physics Publising LLC",
number = "3",

}

TY - JOUR

T1 - Effectiveness of compensating filters in the presence of tissue inhomogeneities.

AU - Sethi, A.

AU - Leybovich, L.

AU - Dogan, Nesrin

AU - Glasgow, G.

PY - 2003/1/1

Y1 - 2003/1/1

N2 - CT based 3D treatment planning systems (3DTPS) can be used to design compensating filters that, in addition to missing tissue compensation, can account for tissue inhomogeneities. The use of computer-driven systems provides a practical, convenient, and accurate method of fabricating compensating filters. In this work, we have evaluated a commercially available PAR Scientific DIGIMILL milling machine linked with FOCUS 3DTPS. Compensating filters were fabricated using refined gypsum material with no additives. Thus, filters were of manageable dimensions and were not sensitive to common machining errors. Compensating filters were evaluated using a homogeneous step phantom and step phantoms containing various internal inhomogeneities (air, cork, and bone). The accuracy of two planning algorithms used to design filters was experimentally evaluated. The superposition algorithm was found to produce better agreement with measurements than the Clarkson algorithm. Phantom measurements have demonstrated that compensating filters were able to produce a uniform dose distribution along the compensation plane in the presence of tissue inhomogeneity. However, the dose variation was greatly amplified in planes located beyond the inhomogeneity when a single compensated beam was used. The use of parallel-opposed compensated beams eliminated this problem. Both lateral and depth-dose uniformity was achieved throughout the target volume. (c) 2003 American College of Medical Physics.

AB - CT based 3D treatment planning systems (3DTPS) can be used to design compensating filters that, in addition to missing tissue compensation, can account for tissue inhomogeneities. The use of computer-driven systems provides a practical, convenient, and accurate method of fabricating compensating filters. In this work, we have evaluated a commercially available PAR Scientific DIGIMILL milling machine linked with FOCUS 3DTPS. Compensating filters were fabricated using refined gypsum material with no additives. Thus, filters were of manageable dimensions and were not sensitive to common machining errors. Compensating filters were evaluated using a homogeneous step phantom and step phantoms containing various internal inhomogeneities (air, cork, and bone). The accuracy of two planning algorithms used to design filters was experimentally evaluated. The superposition algorithm was found to produce better agreement with measurements than the Clarkson algorithm. Phantom measurements have demonstrated that compensating filters were able to produce a uniform dose distribution along the compensation plane in the presence of tissue inhomogeneity. However, the dose variation was greatly amplified in planes located beyond the inhomogeneity when a single compensated beam was used. The use of parallel-opposed compensated beams eliminated this problem. Both lateral and depth-dose uniformity was achieved throughout the target volume. (c) 2003 American College of Medical Physics.

UR - http://www.scopus.com/inward/record.url?scp=85024994164&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024994164&partnerID=8YFLogxK

U2 - 10.1120/jacmp.v4i3.2517

DO - 10.1120/jacmp.v4i3.2517

M3 - Article

C2 - 12841791

AN - SCOPUS:85024994164

VL - 4

SP - 209

EP - 216

JO - Journal of applied clinical medical physics / American College of Medical Physics

JF - Journal of applied clinical medical physics / American College of Medical Physics

SN - 1526-9914

IS - 3

ER -