Design and evaluation of a radio frequency coil for nuclear magnetic resonance imaging of fluorine and protons

P. M. Joseph, Joel Fishman

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

A frequency-switchable, homogeneous-field rf saddle coil has been designed for imaging both protons (1H, 59.1 MHz) and fluorine (19F, 55.6 MHz) on a 1.4-T superconducting small-bore nuclear magnetic resonance imager. Frequency and impedance switching is accomplished by external capacitance and cable length changes; these operations permit imaging of both nuclei without perturbing the sample. The coil is optimized for 19F operation, yet performs better at the proton frequency than does the unswitched 19F coil. The angular distribution of the coil's wires and the use of distributed capacitors are designed to optimize field homogeneity and Q. A quantitative image of field homogeneity is presented. The coil is suitable for imaging small animals (7-cm-diam bore) and couples far better to small samples than does our standard receiver coil (15.2 cm in diameter). Images of phantoms and rats injected with a perfluorinated blood substitute are presented.

Original languageEnglish
Pages (from-to)679-683
Number of pages5
JournalMedical Physics
Volume12
Issue number6
StatePublished - Dec 1 1985
Externally publishedYes

Fingerprint

Fluorine
Radio
Protons
Magnetic Resonance Spectroscopy
Magnetic Resonance Imaging
Blood Substitutes
Electric Impedance

ASJC Scopus subject areas

  • Biophysics

Cite this

Design and evaluation of a radio frequency coil for nuclear magnetic resonance imaging of fluorine and protons. / Joseph, P. M.; Fishman, Joel.

In: Medical Physics, Vol. 12, No. 6, 01.12.1985, p. 679-683.

Research output: Contribution to journalArticle

@article{20fb3bd955dd4551a6b96a88f75e5d84,
title = "Design and evaluation of a radio frequency coil for nuclear magnetic resonance imaging of fluorine and protons",
abstract = "A frequency-switchable, homogeneous-field rf saddle coil has been designed for imaging both protons (1H, 59.1 MHz) and fluorine (19F, 55.6 MHz) on a 1.4-T superconducting small-bore nuclear magnetic resonance imager. Frequency and impedance switching is accomplished by external capacitance and cable length changes; these operations permit imaging of both nuclei without perturbing the sample. The coil is optimized for 19F operation, yet performs better at the proton frequency than does the unswitched 19F coil. The angular distribution of the coil's wires and the use of distributed capacitors are designed to optimize field homogeneity and Q. A quantitative image of field homogeneity is presented. The coil is suitable for imaging small animals (7-cm-diam bore) and couples far better to small samples than does our standard receiver coil (15.2 cm in diameter). Images of phantoms and rats injected with a perfluorinated blood substitute are presented.",
author = "Joseph, {P. M.} and Joel Fishman",
year = "1985",
month = "12",
day = "1",
language = "English",
volume = "12",
pages = "679--683",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - Design and evaluation of a radio frequency coil for nuclear magnetic resonance imaging of fluorine and protons

AU - Joseph, P. M.

AU - Fishman, Joel

PY - 1985/12/1

Y1 - 1985/12/1

N2 - A frequency-switchable, homogeneous-field rf saddle coil has been designed for imaging both protons (1H, 59.1 MHz) and fluorine (19F, 55.6 MHz) on a 1.4-T superconducting small-bore nuclear magnetic resonance imager. Frequency and impedance switching is accomplished by external capacitance and cable length changes; these operations permit imaging of both nuclei without perturbing the sample. The coil is optimized for 19F operation, yet performs better at the proton frequency than does the unswitched 19F coil. The angular distribution of the coil's wires and the use of distributed capacitors are designed to optimize field homogeneity and Q. A quantitative image of field homogeneity is presented. The coil is suitable for imaging small animals (7-cm-diam bore) and couples far better to small samples than does our standard receiver coil (15.2 cm in diameter). Images of phantoms and rats injected with a perfluorinated blood substitute are presented.

AB - A frequency-switchable, homogeneous-field rf saddle coil has been designed for imaging both protons (1H, 59.1 MHz) and fluorine (19F, 55.6 MHz) on a 1.4-T superconducting small-bore nuclear magnetic resonance imager. Frequency and impedance switching is accomplished by external capacitance and cable length changes; these operations permit imaging of both nuclei without perturbing the sample. The coil is optimized for 19F operation, yet performs better at the proton frequency than does the unswitched 19F coil. The angular distribution of the coil's wires and the use of distributed capacitors are designed to optimize field homogeneity and Q. A quantitative image of field homogeneity is presented. The coil is suitable for imaging small animals (7-cm-diam bore) and couples far better to small samples than does our standard receiver coil (15.2 cm in diameter). Images of phantoms and rats injected with a perfluorinated blood substitute are presented.

UR - http://www.scopus.com/inward/record.url?scp=0022339148&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022339148&partnerID=8YFLogxK

M3 - Article

VL - 12

SP - 679

EP - 683

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -