Purpose: We evaluated the validity and interrater reliability of encephalographer interpretation of color density spectral array EEG for seizure identification was evaluated in critically ill children and explored predictors of accurate seizure identification. Methods: Conventional EEG tracings from 21 consecutive critically ill children were scored for electrographic seizures. Four 2-hour long segments from each subject were converted to 8-channel color density spectral array displays, yielding 84 images. Eight encephalographers received color density spectral array training and circled elements thought to represent seizures. Images were reviewed in random order (Group A) or with information regarding seizure presence in the initial 30 minutes and with subject images in order (Group B). Sensitivity, specificity, and interrater reliability were calculated. Factors associated with color density spectral array seizure identification were assessed. Results: Seizure prevalence was 43% on conventional EEG. Specificity was significantly higher for Group A than Group B (92.3% vs. 78.2%, P < 0.00). Sensitivity was not significantly different between Groups A and B (64.8% vs. 75%, P = 0.22). Interrater reliability was moderate in both groups. Ten percent of images were falsely classified as containing a seizure. Seizure duration ≥2 minutes predicted identification (P < 0.001). Conclusions: Color density spectral array may be a useful screening tool for seizure identification by encephalographers, but it does not identify all seizures and false positives occur.

Original languageEnglish (US)
Pages (from-to)371-375
Number of pages5
JournalJournal of Clinical Neurophysiology
Volume30
Issue number4
DOIs
StatePublished - Aug 2013
Externally publishedYes

Fingerprint

Critical Illness
Seizures
Color
Electroencephalography
Reproducibility of Results
Sensitivity and Specificity

Keywords

  • Color density spectral array
  • EEG
  • EEG monitoring.
  • Pediatric
  • Seizure

ASJC Scopus subject areas

  • Clinical Neurology
  • Neurology
  • Physiology
  • Physiology (medical)

Cite this

Pensirikul, A., Beslow, L. A., Kessler, S. K., Sanchez, S. M., Topjian, A. A., Dlugos, D. J., & Abend, N. S. (2013). Density spectral array for seizure identification in critically ill children. Journal of Clinical Neurophysiology, 30(4), 371-375. https://doi.org/10.1097/WNP.0b013e31829de01c

Density spectral array for seizure identification in critically ill children. / Pensirikul, Alyssa; Beslow, Lauren A.; Kessler, Sudha K.; Sanchez, Sarah M.; Topjian, Alexis A.; Dlugos, Dennis J.; Abend, Nicholas S.

In: Journal of Clinical Neurophysiology, Vol. 30, No. 4, 08.2013, p. 371-375.

Research output: Contribution to journalArticle

Pensirikul, A, Beslow, LA, Kessler, SK, Sanchez, SM, Topjian, AA, Dlugos, DJ & Abend, NS 2013, 'Density spectral array for seizure identification in critically ill children', Journal of Clinical Neurophysiology, vol. 30, no. 4, pp. 371-375. https://doi.org/10.1097/WNP.0b013e31829de01c
Pensirikul, Alyssa ; Beslow, Lauren A. ; Kessler, Sudha K. ; Sanchez, Sarah M. ; Topjian, Alexis A. ; Dlugos, Dennis J. ; Abend, Nicholas S. / Density spectral array for seizure identification in critically ill children. In: Journal of Clinical Neurophysiology. 2013 ; Vol. 30, No. 4. pp. 371-375.
@article{6847d062c07b494794ff2bc6f63372ff,
title = "Density spectral array for seizure identification in critically ill children",
abstract = "Purpose: We evaluated the validity and interrater reliability of encephalographer interpretation of color density spectral array EEG for seizure identification was evaluated in critically ill children and explored predictors of accurate seizure identification. Methods: Conventional EEG tracings from 21 consecutive critically ill children were scored for electrographic seizures. Four 2-hour long segments from each subject were converted to 8-channel color density spectral array displays, yielding 84 images. Eight encephalographers received color density spectral array training and circled elements thought to represent seizures. Images were reviewed in random order (Group A) or with information regarding seizure presence in the initial 30 minutes and with subject images in order (Group B). Sensitivity, specificity, and interrater reliability were calculated. Factors associated with color density spectral array seizure identification were assessed. Results: Seizure prevalence was 43{\%} on conventional EEG. Specificity was significantly higher for Group A than Group B (92.3{\%} vs. 78.2{\%}, P < 0.00). Sensitivity was not significantly different between Groups A and B (64.8{\%} vs. 75{\%}, P = 0.22). Interrater reliability was moderate in both groups. Ten percent of images were falsely classified as containing a seizure. Seizure duration ≥2 minutes predicted identification (P < 0.001). Conclusions: Color density spectral array may be a useful screening tool for seizure identification by encephalographers, but it does not identify all seizures and false positives occur.",
keywords = "Color density spectral array, EEG, EEG monitoring., Pediatric, Seizure",
author = "Alyssa Pensirikul and Beslow, {Lauren A.} and Kessler, {Sudha K.} and Sanchez, {Sarah M.} and Topjian, {Alexis A.} and Dlugos, {Dennis J.} and Abend, {Nicholas S.}",
year = "2013",
month = "8",
doi = "10.1097/WNP.0b013e31829de01c",
language = "English (US)",
volume = "30",
pages = "371--375",
journal = "Journal of Clinical Neurophysiology",
issn = "0736-0258",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Density spectral array for seizure identification in critically ill children

AU - Pensirikul, Alyssa

AU - Beslow, Lauren A.

AU - Kessler, Sudha K.

AU - Sanchez, Sarah M.

AU - Topjian, Alexis A.

AU - Dlugos, Dennis J.

AU - Abend, Nicholas S.

PY - 2013/8

Y1 - 2013/8

N2 - Purpose: We evaluated the validity and interrater reliability of encephalographer interpretation of color density spectral array EEG for seizure identification was evaluated in critically ill children and explored predictors of accurate seizure identification. Methods: Conventional EEG tracings from 21 consecutive critically ill children were scored for electrographic seizures. Four 2-hour long segments from each subject were converted to 8-channel color density spectral array displays, yielding 84 images. Eight encephalographers received color density spectral array training and circled elements thought to represent seizures. Images were reviewed in random order (Group A) or with information regarding seizure presence in the initial 30 minutes and with subject images in order (Group B). Sensitivity, specificity, and interrater reliability were calculated. Factors associated with color density spectral array seizure identification were assessed. Results: Seizure prevalence was 43% on conventional EEG. Specificity was significantly higher for Group A than Group B (92.3% vs. 78.2%, P < 0.00). Sensitivity was not significantly different between Groups A and B (64.8% vs. 75%, P = 0.22). Interrater reliability was moderate in both groups. Ten percent of images were falsely classified as containing a seizure. Seizure duration ≥2 minutes predicted identification (P < 0.001). Conclusions: Color density spectral array may be a useful screening tool for seizure identification by encephalographers, but it does not identify all seizures and false positives occur.

AB - Purpose: We evaluated the validity and interrater reliability of encephalographer interpretation of color density spectral array EEG for seizure identification was evaluated in critically ill children and explored predictors of accurate seizure identification. Methods: Conventional EEG tracings from 21 consecutive critically ill children were scored for electrographic seizures. Four 2-hour long segments from each subject were converted to 8-channel color density spectral array displays, yielding 84 images. Eight encephalographers received color density spectral array training and circled elements thought to represent seizures. Images were reviewed in random order (Group A) or with information regarding seizure presence in the initial 30 minutes and with subject images in order (Group B). Sensitivity, specificity, and interrater reliability were calculated. Factors associated with color density spectral array seizure identification were assessed. Results: Seizure prevalence was 43% on conventional EEG. Specificity was significantly higher for Group A than Group B (92.3% vs. 78.2%, P < 0.00). Sensitivity was not significantly different between Groups A and B (64.8% vs. 75%, P = 0.22). Interrater reliability was moderate in both groups. Ten percent of images were falsely classified as containing a seizure. Seizure duration ≥2 minutes predicted identification (P < 0.001). Conclusions: Color density spectral array may be a useful screening tool for seizure identification by encephalographers, but it does not identify all seizures and false positives occur.

KW - Color density spectral array

KW - EEG

KW - EEG monitoring.

KW - Pediatric

KW - Seizure

UR - http://www.scopus.com/inward/record.url?scp=84882360157&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84882360157&partnerID=8YFLogxK

U2 - 10.1097/WNP.0b013e31829de01c

DO - 10.1097/WNP.0b013e31829de01c

M3 - Article

C2 - 23912575

AN - SCOPUS:84882360157

VL - 30

SP - 371

EP - 375

JO - Journal of Clinical Neurophysiology

JF - Journal of Clinical Neurophysiology

SN - 0736-0258

IS - 4

ER -