Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis

Ihab Mohamed Osman, Hany Ahmed Helaly, Moones Abdalla, Mohamed Abou Shousha

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

Background: Evaluating the corneal biomechanical changes using the Ocular Response Analyzer and the Corvis ST in eyes with incision lenticule extraction (SMILE) and laser assisted in situ keratomileusis (LASIK). Methods: This is a retrospective study that included 50 eyes equally divided into two groups. The first group included eyes that underwent SMILE procedure using VisuMax® 500 kHz laser system (Carl Zeiss Meditec, Jena, Germany) and the second group included eyes that underwent LASIK procedure using the EX500 Allegretto excimer laser platform (Wavelight GmbH, Erlangen, Germany). The Ocular Response Analyzer (ORA) and the Corvis ST (CST) measured the corneal biomechanical changes before and after the procedures. Results: The ORA showed significant decrease of corneal hysteresis (CH) and corneal resistance factor (CRF) in both groups postoperatively. The percentage of change of CH and CRF were found to be significantly higher in group II. There was no significant difference in the IOP with the ORA and the CST pre and postoperatively in either group. Using CST, the deformation amplitude and HC peak distances increased significantly in both groups. It was also noted that the mean percentage of change of the deformation amplitude was nearly five times higher in group II than group I. Conclusion: Both LASIK and SMILE substantially decreased the corneal biomechanical properties with greater reduction in the LASIK group.

Original languageEnglish (US)
Article number123
JournalBMC Ophthalmology
Volume16
Issue number1
DOIs
StatePublished - Jul 26 2016
Externally publishedYes

Fingerprint

Laser In Situ Keratomileusis
R Factors
Germany
Excimer Lasers
Lasers
Retrospective Studies

Keywords

  • Biomechanics
  • Corvis ST
  • LASIK
  • SMILE

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis. / Osman, Ihab Mohamed; Helaly, Hany Ahmed; Abdalla, Moones; Abou Shousha, Mohamed.

In: BMC Ophthalmology, Vol. 16, No. 1, 123, 26.07.2016.

Research output: Contribution to journalArticle

@article{9c35e6eee41242cc9f123653a9182b83,
title = "Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis",
abstract = "Background: Evaluating the corneal biomechanical changes using the Ocular Response Analyzer and the Corvis ST in eyes with incision lenticule extraction (SMILE) and laser assisted in situ keratomileusis (LASIK). Methods: This is a retrospective study that included 50 eyes equally divided into two groups. The first group included eyes that underwent SMILE procedure using VisuMax{\circledR} 500 kHz laser system (Carl Zeiss Meditec, Jena, Germany) and the second group included eyes that underwent LASIK procedure using the EX500 Allegretto excimer laser platform (Wavelight GmbH, Erlangen, Germany). The Ocular Response Analyzer (ORA) and the Corvis ST (CST) measured the corneal biomechanical changes before and after the procedures. Results: The ORA showed significant decrease of corneal hysteresis (CH) and corneal resistance factor (CRF) in both groups postoperatively. The percentage of change of CH and CRF were found to be significantly higher in group II. There was no significant difference in the IOP with the ORA and the CST pre and postoperatively in either group. Using CST, the deformation amplitude and HC peak distances increased significantly in both groups. It was also noted that the mean percentage of change of the deformation amplitude was nearly five times higher in group II than group I. Conclusion: Both LASIK and SMILE substantially decreased the corneal biomechanical properties with greater reduction in the LASIK group.",
keywords = "Biomechanics, Corvis ST, LASIK, SMILE",
author = "Osman, {Ihab Mohamed} and Helaly, {Hany Ahmed} and Moones Abdalla and {Abou Shousha}, Mohamed",
year = "2016",
month = "7",
day = "26",
doi = "10.1186/s12886-016-0304-3",
language = "English (US)",
volume = "16",
journal = "BMC Ophthalmology",
issn = "1471-2415",
publisher = "BioMed Central",
number = "1",

}

TY - JOUR

T1 - Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis

AU - Osman, Ihab Mohamed

AU - Helaly, Hany Ahmed

AU - Abdalla, Moones

AU - Abou Shousha, Mohamed

PY - 2016/7/26

Y1 - 2016/7/26

N2 - Background: Evaluating the corneal biomechanical changes using the Ocular Response Analyzer and the Corvis ST in eyes with incision lenticule extraction (SMILE) and laser assisted in situ keratomileusis (LASIK). Methods: This is a retrospective study that included 50 eyes equally divided into two groups. The first group included eyes that underwent SMILE procedure using VisuMax® 500 kHz laser system (Carl Zeiss Meditec, Jena, Germany) and the second group included eyes that underwent LASIK procedure using the EX500 Allegretto excimer laser platform (Wavelight GmbH, Erlangen, Germany). The Ocular Response Analyzer (ORA) and the Corvis ST (CST) measured the corneal biomechanical changes before and after the procedures. Results: The ORA showed significant decrease of corneal hysteresis (CH) and corneal resistance factor (CRF) in both groups postoperatively. The percentage of change of CH and CRF were found to be significantly higher in group II. There was no significant difference in the IOP with the ORA and the CST pre and postoperatively in either group. Using CST, the deformation amplitude and HC peak distances increased significantly in both groups. It was also noted that the mean percentage of change of the deformation amplitude was nearly five times higher in group II than group I. Conclusion: Both LASIK and SMILE substantially decreased the corneal biomechanical properties with greater reduction in the LASIK group.

AB - Background: Evaluating the corneal biomechanical changes using the Ocular Response Analyzer and the Corvis ST in eyes with incision lenticule extraction (SMILE) and laser assisted in situ keratomileusis (LASIK). Methods: This is a retrospective study that included 50 eyes equally divided into two groups. The first group included eyes that underwent SMILE procedure using VisuMax® 500 kHz laser system (Carl Zeiss Meditec, Jena, Germany) and the second group included eyes that underwent LASIK procedure using the EX500 Allegretto excimer laser platform (Wavelight GmbH, Erlangen, Germany). The Ocular Response Analyzer (ORA) and the Corvis ST (CST) measured the corneal biomechanical changes before and after the procedures. Results: The ORA showed significant decrease of corneal hysteresis (CH) and corneal resistance factor (CRF) in both groups postoperatively. The percentage of change of CH and CRF were found to be significantly higher in group II. There was no significant difference in the IOP with the ORA and the CST pre and postoperatively in either group. Using CST, the deformation amplitude and HC peak distances increased significantly in both groups. It was also noted that the mean percentage of change of the deformation amplitude was nearly five times higher in group II than group I. Conclusion: Both LASIK and SMILE substantially decreased the corneal biomechanical properties with greater reduction in the LASIK group.

KW - Biomechanics

KW - Corvis ST

KW - LASIK

KW - SMILE

UR - http://www.scopus.com/inward/record.url?scp=84979256753&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84979256753&partnerID=8YFLogxK

U2 - 10.1186/s12886-016-0304-3

DO - 10.1186/s12886-016-0304-3

M3 - Article

C2 - 27457241

AN - SCOPUS:84979256753

VL - 16

JO - BMC Ophthalmology

JF - BMC Ophthalmology

SN - 1471-2415

IS - 1

M1 - 123

ER -