Confidence images for MR spectroscopic imaging

Karl Young, Dennis Khetselius, Brian J. Soher, Andrew A Maudsley

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Automated spectral analysis and estimation of signal amplitudes from magnetic resonance data generally constitutes a difficult nonlinear optimization problem. Obtaining a measure of the degree of confidence that one has in the estimated parameters is as important as the estimates themselves. This is particularly important if clinical diagnoses are to be based on estimated metabolite levels, as in applications of MR Spectroscopic Imaging for human studies. In this report, a standard method of obtaining confidence intervals for nonlinear estimation is applied to simulated data and short-TE clinical proton spectroscopic imaging data sets of human brain. So-called 'confidence images' are generated to serve as visual indicators of how much trust should be placed in interpretation of spatial variations seen in images derived from fitted metabolite parameter estimates. This method is introduced in a Bayesian framework to enable comparison with similar techniques using Cramer-Rao bounds and the residuals of fitted results. (C) 2000 Wiley-Liss, Inc.

Original languageEnglish
Pages (from-to)537-545
Number of pages9
JournalMagnetic Resonance in Medicine
Volume44
Issue number4
DOIs
StatePublished - Oct 24 2000
Externally publishedYes

Fingerprint

Protons
Magnetic Resonance Spectroscopy
Confidence Intervals
Brain
Datasets

Keywords

  • Confidence limits
  • NMR
  • Nonlinear optimization
  • Spectral analysis
  • Spectroscopic imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Confidence images for MR spectroscopic imaging. / Young, Karl; Khetselius, Dennis; Soher, Brian J.; Maudsley, Andrew A.

In: Magnetic Resonance in Medicine, Vol. 44, No. 4, 24.10.2000, p. 537-545.

Research output: Contribution to journalArticle

Young, Karl ; Khetselius, Dennis ; Soher, Brian J. ; Maudsley, Andrew A. / Confidence images for MR spectroscopic imaging. In: Magnetic Resonance in Medicine. 2000 ; Vol. 44, No. 4. pp. 537-545.
@article{e0eb79e5ad6f4ac289234701e9489bd2,
title = "Confidence images for MR spectroscopic imaging",
abstract = "Automated spectral analysis and estimation of signal amplitudes from magnetic resonance data generally constitutes a difficult nonlinear optimization problem. Obtaining a measure of the degree of confidence that one has in the estimated parameters is as important as the estimates themselves. This is particularly important if clinical diagnoses are to be based on estimated metabolite levels, as in applications of MR Spectroscopic Imaging for human studies. In this report, a standard method of obtaining confidence intervals for nonlinear estimation is applied to simulated data and short-TE clinical proton spectroscopic imaging data sets of human brain. So-called 'confidence images' are generated to serve as visual indicators of how much trust should be placed in interpretation of spatial variations seen in images derived from fitted metabolite parameter estimates. This method is introduced in a Bayesian framework to enable comparison with similar techniques using Cramer-Rao bounds and the residuals of fitted results. (C) 2000 Wiley-Liss, Inc.",
keywords = "Confidence limits, NMR, Nonlinear optimization, Spectral analysis, Spectroscopic imaging",
author = "Karl Young and Dennis Khetselius and Soher, {Brian J.} and Maudsley, {Andrew A}",
year = "2000",
month = "10",
day = "24",
doi = "10.1002/1522-2594(200010)44:4<537::AID-MRM7>3.0.CO;2-8",
language = "English",
volume = "44",
pages = "537--545",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

TY - JOUR

T1 - Confidence images for MR spectroscopic imaging

AU - Young, Karl

AU - Khetselius, Dennis

AU - Soher, Brian J.

AU - Maudsley, Andrew A

PY - 2000/10/24

Y1 - 2000/10/24

N2 - Automated spectral analysis and estimation of signal amplitudes from magnetic resonance data generally constitutes a difficult nonlinear optimization problem. Obtaining a measure of the degree of confidence that one has in the estimated parameters is as important as the estimates themselves. This is particularly important if clinical diagnoses are to be based on estimated metabolite levels, as in applications of MR Spectroscopic Imaging for human studies. In this report, a standard method of obtaining confidence intervals for nonlinear estimation is applied to simulated data and short-TE clinical proton spectroscopic imaging data sets of human brain. So-called 'confidence images' are generated to serve as visual indicators of how much trust should be placed in interpretation of spatial variations seen in images derived from fitted metabolite parameter estimates. This method is introduced in a Bayesian framework to enable comparison with similar techniques using Cramer-Rao bounds and the residuals of fitted results. (C) 2000 Wiley-Liss, Inc.

AB - Automated spectral analysis and estimation of signal amplitudes from magnetic resonance data generally constitutes a difficult nonlinear optimization problem. Obtaining a measure of the degree of confidence that one has in the estimated parameters is as important as the estimates themselves. This is particularly important if clinical diagnoses are to be based on estimated metabolite levels, as in applications of MR Spectroscopic Imaging for human studies. In this report, a standard method of obtaining confidence intervals for nonlinear estimation is applied to simulated data and short-TE clinical proton spectroscopic imaging data sets of human brain. So-called 'confidence images' are generated to serve as visual indicators of how much trust should be placed in interpretation of spatial variations seen in images derived from fitted metabolite parameter estimates. This method is introduced in a Bayesian framework to enable comparison with similar techniques using Cramer-Rao bounds and the residuals of fitted results. (C) 2000 Wiley-Liss, Inc.

KW - Confidence limits

KW - NMR

KW - Nonlinear optimization

KW - Spectral analysis

KW - Spectroscopic imaging

UR - http://www.scopus.com/inward/record.url?scp=0033776768&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033776768&partnerID=8YFLogxK

U2 - 10.1002/1522-2594(200010)44:4<537::AID-MRM7>3.0.CO;2-8

DO - 10.1002/1522-2594(200010)44:4<537::AID-MRM7>3.0.CO;2-8

M3 - Article

C2 - 11025509

AN - SCOPUS:0033776768

VL - 44

SP - 537

EP - 545

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 4

ER -