Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery

H. Bolooki, W. Williams, Richard J Thurer, A. Vargas, G. A. Kaiser, F. Mack, A. R. Ghahramani

Research output: Contribution to journalArticle

43 Citations (Scopus)
Original languageEnglish
Pages (from-to)756-768
Number of pages13
JournalJournal of Thoracic and Cardiovascular Surgery
Volume72
Issue number5
StatePublished - Dec 1 1976

Fingerprint

Assisted Circulation
Cardiac Surgical Procedures
Intra-Aortic Balloon Pumping
Heart Valve Diseases
Cardiopulmonary Bypass
Thoracic Surgery
Coronary Disease
Retrospective Studies
Hemodynamics
Prospective Studies

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery

Cite this

Bolooki, H., Williams, W., Thurer, R. J., Vargas, A., Kaiser, G. A., Mack, F., & Ghahramani, A. R. (1976). Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery. Journal of Thoracic and Cardiovascular Surgery, 72(5), 756-768.

Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery. / Bolooki, H.; Williams, W.; Thurer, Richard J; Vargas, A.; Kaiser, G. A.; Mack, F.; Ghahramani, A. R.

In: Journal of Thoracic and Cardiovascular Surgery, Vol. 72, No. 5, 01.12.1976, p. 756-768.

Research output: Contribution to journalArticle

Bolooki, H, Williams, W, Thurer, RJ, Vargas, A, Kaiser, GA, Mack, F & Ghahramani, AR 1976, 'Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery', Journal of Thoracic and Cardiovascular Surgery, vol. 72, no. 5, pp. 756-768.
Bolooki, H. ; Williams, W. ; Thurer, Richard J ; Vargas, A. ; Kaiser, G. A. ; Mack, F. ; Ghahramani, A. R. / Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery. In: Journal of Thoracic and Cardiovascular Surgery. 1976 ; Vol. 72, No. 5. pp. 756-768.
@article{986e679634574c5d8417cb874bc27ad5,
title = "Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery",
author = "H. Bolooki and W. Williams and Thurer, {Richard J} and A. Vargas and Kaiser, {G. A.} and F. Mack and Ghahramani, {A. R.}",
year = "1976",
month = "12",
day = "1",
language = "English",
volume = "72",
pages = "756--768",
journal = "Journal of Thoracic and Cardiovascular Surgery",
issn = "0022-5223",
publisher = "Mosby Inc.",
number = "5",

}

TY - JOUR

T1 - Clinical and hemodynamic criteria for use of the intra aortic balloon pump in patients requiring cardiac surgery

AU - Bolooki, H.

AU - Williams, W.

AU - Thurer, Richard J

AU - Vargas, A.

AU - Kaiser, G. A.

AU - Mack, F.

AU - Ghahramani, A. R.

PY - 1976/12/1

Y1 - 1976/12/1

UR - http://www.scopus.com/inward/record.url?scp=0017170406&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017170406&partnerID=8YFLogxK

M3 - Article

VL - 72

SP - 756

EP - 768

JO - Journal of Thoracic and Cardiovascular Surgery

JF - Journal of Thoracic and Cardiovascular Surgery

SN - 0022-5223

IS - 5

ER -