Altered Bulbar Conjunctival Microcirculation in Response to Contact Lens Wear

Wan Chen, Zhe Xu, Hong Jiang, Jin Zhou, Liang Wang, Jianhua Wang

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

PURPOSE:: This study was conducted to determine blood flow velocities and corresponding vessel diameters to characterize the response of the bulbar conjunctival microvasculature to contact lens wear. METHODS:: A functional slit-lamp biomicroscope (FSLB), an adapted traditional slitlamp, was used to image the temporal bulbar conjunctiva of 22 healthy subjects before and after 6 hr of contact lens wear. All of the measurable venules on the conjunctiva were processed to yield vessel diameters and blood flow velocities. RESULTS:: The average blood flow velocity increased from 0.51±0.20 to 0.65±0.22 mm/sec (P<0.001) after 6 hr of lens wear. The blood flow velocity distribution showed a velocity increase that correlated with the vessel diameter increase from the baseline (r=0.826, P<0.05). This pattern maintained a similar trend after 6 hr of lens wear (r=0.925, P<0.05), and increased velocities were found across all of the vessel diameter ranges (P<0.001). CONCLUSIONS:: Blood flow velocity increases across all of the vessel diameter ranges in response to contact lens wear. Functional slitlamp biomicroscope is capable of characterizing the bulbar microvascular response to contact lens wear.

Original languageEnglish (US)
JournalEye and Contact Lens
DOIs
StateAccepted/In press - Apr 13 2016

Fingerprint

Blood Flow Velocity
Contact Lenses
Microcirculation
Conjunctiva
Lenses
Venules
Microvessels
Healthy Volunteers

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Altered Bulbar Conjunctival Microcirculation in Response to Contact Lens Wear. / Chen, Wan; Xu, Zhe; Jiang, Hong; Zhou, Jin; Wang, Liang; Wang, Jianhua.

In: Eye and Contact Lens, 13.04.2016.

Research output: Contribution to journalArticle

@article{3185dc4dd243448b8a1842636ad0ba39,
title = "Altered Bulbar Conjunctival Microcirculation in Response to Contact Lens Wear",
abstract = "PURPOSE:: This study was conducted to determine blood flow velocities and corresponding vessel diameters to characterize the response of the bulbar conjunctival microvasculature to contact lens wear. METHODS:: A functional slit-lamp biomicroscope (FSLB), an adapted traditional slitlamp, was used to image the temporal bulbar conjunctiva of 22 healthy subjects before and after 6 hr of contact lens wear. All of the measurable venules on the conjunctiva were processed to yield vessel diameters and blood flow velocities. RESULTS:: The average blood flow velocity increased from 0.51±0.20 to 0.65±0.22 mm/sec (P<0.001) after 6 hr of lens wear. The blood flow velocity distribution showed a velocity increase that correlated with the vessel diameter increase from the baseline (r=0.826, P<0.05). This pattern maintained a similar trend after 6 hr of lens wear (r=0.925, P<0.05), and increased velocities were found across all of the vessel diameter ranges (P<0.001). CONCLUSIONS:: Blood flow velocity increases across all of the vessel diameter ranges in response to contact lens wear. Functional slitlamp biomicroscope is capable of characterizing the bulbar microvascular response to contact lens wear.",
author = "Wan Chen and Zhe Xu and Hong Jiang and Jin Zhou and Liang Wang and Jianhua Wang",
year = "2016",
month = "4",
day = "13",
doi = "10.1097/ICL.0000000000000241",
language = "English (US)",
journal = "Eye and Contact Lense",
issn = "1542-2321",
publisher = "Lippincott Williams and Wilkins",

}

TY - JOUR

T1 - Altered Bulbar Conjunctival Microcirculation in Response to Contact Lens Wear

AU - Chen, Wan

AU - Xu, Zhe

AU - Jiang, Hong

AU - Zhou, Jin

AU - Wang, Liang

AU - Wang, Jianhua

PY - 2016/4/13

Y1 - 2016/4/13

N2 - PURPOSE:: This study was conducted to determine blood flow velocities and corresponding vessel diameters to characterize the response of the bulbar conjunctival microvasculature to contact lens wear. METHODS:: A functional slit-lamp biomicroscope (FSLB), an adapted traditional slitlamp, was used to image the temporal bulbar conjunctiva of 22 healthy subjects before and after 6 hr of contact lens wear. All of the measurable venules on the conjunctiva were processed to yield vessel diameters and blood flow velocities. RESULTS:: The average blood flow velocity increased from 0.51±0.20 to 0.65±0.22 mm/sec (P<0.001) after 6 hr of lens wear. The blood flow velocity distribution showed a velocity increase that correlated with the vessel diameter increase from the baseline (r=0.826, P<0.05). This pattern maintained a similar trend after 6 hr of lens wear (r=0.925, P<0.05), and increased velocities were found across all of the vessel diameter ranges (P<0.001). CONCLUSIONS:: Blood flow velocity increases across all of the vessel diameter ranges in response to contact lens wear. Functional slitlamp biomicroscope is capable of characterizing the bulbar microvascular response to contact lens wear.

AB - PURPOSE:: This study was conducted to determine blood flow velocities and corresponding vessel diameters to characterize the response of the bulbar conjunctival microvasculature to contact lens wear. METHODS:: A functional slit-lamp biomicroscope (FSLB), an adapted traditional slitlamp, was used to image the temporal bulbar conjunctiva of 22 healthy subjects before and after 6 hr of contact lens wear. All of the measurable venules on the conjunctiva were processed to yield vessel diameters and blood flow velocities. RESULTS:: The average blood flow velocity increased from 0.51±0.20 to 0.65±0.22 mm/sec (P<0.001) after 6 hr of lens wear. The blood flow velocity distribution showed a velocity increase that correlated with the vessel diameter increase from the baseline (r=0.826, P<0.05). This pattern maintained a similar trend after 6 hr of lens wear (r=0.925, P<0.05), and increased velocities were found across all of the vessel diameter ranges (P<0.001). CONCLUSIONS:: Blood flow velocity increases across all of the vessel diameter ranges in response to contact lens wear. Functional slitlamp biomicroscope is capable of characterizing the bulbar microvascular response to contact lens wear.

UR - http://www.scopus.com/inward/record.url?scp=84963624947&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84963624947&partnerID=8YFLogxK

U2 - 10.1097/ICL.0000000000000241

DO - 10.1097/ICL.0000000000000241

M3 - Article

C2 - 27078615

AN - SCOPUS:84963624947

JO - Eye and Contact Lense

JF - Eye and Contact Lense

SN - 1542-2321

ER -