Accuracy of providers' assessment of pain during intrauterine device insertion

Karla Maguire, Kathleen Morrell, Carolyn Westhoff, Anne Davis

Research output: Contribution to journalArticle

16 Scopus citations

Abstract

Background Providers often underestimate patient pain. This study investigated if providers accurately assess pain during intrauterine device (IUD) insertion. Study Design This is a secondary analysis of a randomized trial. Participants rated pain on a 100-mm visual analogue scale (VAS). Providers marked a similar VAS for maximum level and timing of participant pain. Results The mean patient maximum pain was 64.8 mm (SD, 27) compared to 35.3 mm (SD, 26) rated by the provider (p<.001). Patient and provider agreement on most painful time point of procedure was weak (kappa statistic, 0.16). Conclusions Providers underestimate pain during IUD insertion. Implications To our knowledge, this is the first paper to compare provider and patient perceptions of pain during IUD insertion. Understanding this relationship will help guide further research about IUD insertion pain and techniques and could improve patient counseling.

Original languageEnglish (US)
Pages (from-to)22-24
Number of pages3
JournalContraception
Volume89
Issue number1
DOIs
StatePublished - Jan 1 2014

    Fingerprint

Keywords

  • Intrauterine device insertion
  • IUD insertion
  • Pain
  • Provider perception

ASJC Scopus subject areas

  • Reproductive Medicine
  • Obstetrics and Gynecology

Cite this