T1 - A prospective, multicenter, single-blind study assessing indices of SNAP II versus BIS VISTA on surgical patients undergoing general anesthesia
AU - Bergese, Sergio D.
AU - Uribe, Alberto A.
AU - Puente, Erika G.
AU - Marcus, R. Jay L.
AU - Krohn, Randall J.
AU - Docsa, Steven
AU - Soto, Roy G.
AU - Candiotti, Keith A.
N1 - Publisher Copyright:
© Sergio D Bergese, Alberto A Uribe, Erika G Puente, R-Jay L Marcus, Randall J Krohn, Steven Docsa, Roy G Soto, Keith A Candiotti. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 03.02.2017. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on http://www.researchprotocols.org, as well as this copyright and license information must be included.
PY - 2017/2
Y1 - 2017/2
N2 - Background: Traditionally, anesthesiologists have relied on nonspecific subjective and objective physical signs to assess patients' comfort level and depth of anesthesia. Commercial development of electrical monitors, which use low- and high-frequency electroencephalogram (EEG) signals, have been developed to enhance the assessment of patients' level of consciousness. Multiple studies have shown that monitoring patients' consciousness levels can help in reducing drug consumption, anesthesia-related adverse events, and recovery time. This clinical study will provide information by simultaneously comparing the performance of the SNAP II (a single-channel EEG device) and the bispectral index (BIS) VISTA (a dual-channel EEG device) by assessing their efficacy in monitoring different anesthetic states in patients undergoing general anesthesia. Objective: The primary objective of this study is to establish the range of index values for the SNAP II corresponding to each anesthetic state (preinduction, loss of response, maintenance, first purposeful response, and extubation). The secondary objectives will assess the range of index values for BIS VISTA corresponding to each anesthetic state compared to published BIS VISTA range information, and estimate the area under the curve, sensitivity, and specificity for both devices. Methods: This is a multicenter, prospective, double-arm, parallel assignment, single-blind study involving patients undergoing elective surgery that requires general anesthesia. The study will include 40 patients and will be conducted at the following sites: The Ohio State University Medical Center (Columbus, OH); Northwestern University Prentice Women's Hospital (Chicago, IL); and University of Miami Jackson Memorial Hospital (Miami, FL). The study will assess the predictive value of SNAP II versus BIS VISTA indices at various anesthetic states in patients undergoing general anesthesia (preinduction, loss of response, maintenance, first purposeful response, and extubation). The SNAP II and BIS VISTA electrode arrays will be placed on the patient's forehead on opposite sides. The hemisphere location for both devices' electrodes will be equally alternated among the patient population. The index values for both devices will be recorded and correlated with the scorings received by performing the Modified Observer's Assessment of Alertness and Sedation and the American Society of Anesthesiologists Continuum of Depth of Sedation, at different stages of anesthesia. Results: Enrollment for this study has been completed and statistical data analyses are currently underway. Conclusions: The results of this trial will provide information that will simultaneously compare the performance of SNAP II and BIS VISTA devices, with regards to monitoring different anesthesia states among patients.
AB - Background: Traditionally, anesthesiologists have relied on nonspecific subjective and objective physical signs to assess patients' comfort level and depth of anesthesia. Commercial development of electrical monitors, which use low- and high-frequency electroencephalogram (EEG) signals, have been developed to enhance the assessment of patients' level of consciousness. Multiple studies have shown that monitoring patients' consciousness levels can help in reducing drug consumption, anesthesia-related adverse events, and recovery time. This clinical study will provide information by simultaneously comparing the performance of the SNAP II (a single-channel EEG device) and the bispectral index (BIS) VISTA (a dual-channel EEG device) by assessing their efficacy in monitoring different anesthetic states in patients undergoing general anesthesia. Objective: The primary objective of this study is to establish the range of index values for the SNAP II corresponding to each anesthetic state (preinduction, loss of response, maintenance, first purposeful response, and extubation). The secondary objectives will assess the range of index values for BIS VISTA corresponding to each anesthetic state compared to published BIS VISTA range information, and estimate the area under the curve, sensitivity, and specificity for both devices. Methods: This is a multicenter, prospective, double-arm, parallel assignment, single-blind study involving patients undergoing elective surgery that requires general anesthesia. The study will include 40 patients and will be conducted at the following sites: The Ohio State University Medical Center (Columbus, OH); Northwestern University Prentice Women's Hospital (Chicago, IL); and University of Miami Jackson Memorial Hospital (Miami, FL). The study will assess the predictive value of SNAP II versus BIS VISTA indices at various anesthetic states in patients undergoing general anesthesia (preinduction, loss of response, maintenance, first purposeful response, and extubation). The SNAP II and BIS VISTA electrode arrays will be placed on the patient's forehead on opposite sides. The hemisphere location for both devices' electrodes will be equally alternated among the patient population. The index values for both devices will be recorded and correlated with the scorings received by performing the Modified Observer's Assessment of Alertness and Sedation and the American Society of Anesthesiologists Continuum of Depth of Sedation, at different stages of anesthesia. Results: Enrollment for this study has been completed and statistical data analyses are currently underway. Conclusions: The results of this trial will provide information that will simultaneously compare the performance of SNAP II and BIS VISTA devices, with regards to monitoring different anesthesia states among patients.
KW - BIS VISTA
KW - Bispectral index
KW - EEG monitoring
KW - SNAP II
UR - http://www.scopus.com/inward/record.url?scp=85050009939&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85050009939&partnerID=8YFLogxK
U2 - 10.2196/resprot.6741
DO - 10.2196/resprot.6741
M3 - Article
AN - SCOPUS:85050009939
VL - 6
JO - JMIR Research Protocols
JF - JMIR Research Protocols
SN - 1929-0748
IS - 2
M1 - e15
ER -