A practical step length algorithm using lower limb angular velocities

E. Allseits, Vibhor R Agrawal, J. Lučarević, Robert Gailey, Ignacio Gaunaurd, Christopher Bennett

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

The use of Inertial Measurement Units (IMUs) for spatial gait analysis has opened the door to unconstrained measurements within the home and community. Bandwidth, cost limitations, and ease of use has historically restricted the number and location of sensors worn on the body. In this paper, we describe a four-sensor configuration of IMUs placed on the shanks and thighs that is sufficient to provide an accurate measure of temporal gait parameters, spatial gait parameters, and joint angle dynamics during ambulation. Estimating spatial gait parameters solely from gyroscope data is preferred because gyroscopes are less susceptible to sensor noise and a system comprised of only gyroscopes uses decreased bandwidth compared to a typical 9 degree-of-freedom IMU. The purpose of this study was to determine the validity of a novel method of step length estimation using gyroscopes attached to the shanks and thighs. An Inverted Pendulum Model algorithm (IPM) was proposed to calculate step length, stride length, and gait speed. The algorithm incorporates heel-strike events and average forward velocity per step to make these assessments. IMU algorithm accuracy was determined via concurrent validity with an instrumented walkway and results explained via the collision model of gait. The IPM produced accurate estimates of step length, stride length, and gait speed with a mean difference of 3 cm and an RMSE of 6.6 cm for step length, thus establishing a new approach for spatial gait parameter calculation. The lack of numerical integration in IPM makes it well suited for use in continuous monitoring applications where sensor sampling rates are restricted.

Original languageEnglish (US)
JournalJournal of Biomechanics
DOIs
StateAccepted/In press - Jan 1 2017

Fingerprint

Angular velocity
Gait
Units of measurement
Gyroscopes
Lower Extremity
Pendulums
Sensors
Thigh
Gait analysis
Bandwidth
Spatial Analysis
Heel
Walking
Noise
Sampling
Joints
Monitoring
Costs and Cost Analysis
Costs

Keywords

  • Clinical gait analysis
  • Gait speed
  • IMU
  • Step length
  • Stride length

ASJC Scopus subject areas

  • Biophysics
  • Orthopedics and Sports Medicine
  • Biomedical Engineering
  • Rehabilitation

Cite this

A practical step length algorithm using lower limb angular velocities. / Allseits, E.; Agrawal, Vibhor R; Lučarević, J.; Gailey, Robert; Gaunaurd, Ignacio; Bennett, Christopher.

In: Journal of Biomechanics, 01.01.2017.

Research output: Contribution to journalArticle

@article{04c3d1092cc54b548c90793eefb62c2d,
title = "A practical step length algorithm using lower limb angular velocities",
abstract = "The use of Inertial Measurement Units (IMUs) for spatial gait analysis has opened the door to unconstrained measurements within the home and community. Bandwidth, cost limitations, and ease of use has historically restricted the number and location of sensors worn on the body. In this paper, we describe a four-sensor configuration of IMUs placed on the shanks and thighs that is sufficient to provide an accurate measure of temporal gait parameters, spatial gait parameters, and joint angle dynamics during ambulation. Estimating spatial gait parameters solely from gyroscope data is preferred because gyroscopes are less susceptible to sensor noise and a system comprised of only gyroscopes uses decreased bandwidth compared to a typical 9 degree-of-freedom IMU. The purpose of this study was to determine the validity of a novel method of step length estimation using gyroscopes attached to the shanks and thighs. An Inverted Pendulum Model algorithm (IPM) was proposed to calculate step length, stride length, and gait speed. The algorithm incorporates heel-strike events and average forward velocity per step to make these assessments. IMU algorithm accuracy was determined via concurrent validity with an instrumented walkway and results explained via the collision model of gait. The IPM produced accurate estimates of step length, stride length, and gait speed with a mean difference of 3 cm and an RMSE of 6.6 cm for step length, thus establishing a new approach for spatial gait parameter calculation. The lack of numerical integration in IPM makes it well suited for use in continuous monitoring applications where sensor sampling rates are restricted.",
keywords = "Clinical gait analysis, Gait speed, IMU, Step length, Stride length",
author = "E. Allseits and Agrawal, {Vibhor R} and J. Lučarević and Robert Gailey and Ignacio Gaunaurd and Christopher Bennett",
year = "2017",
month = "1",
day = "1",
doi = "10.1016/j.jbiomech.2017.11.010",
language = "English (US)",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - A practical step length algorithm using lower limb angular velocities

AU - Allseits, E.

AU - Agrawal, Vibhor R

AU - Lučarević, J.

AU - Gailey, Robert

AU - Gaunaurd, Ignacio

AU - Bennett, Christopher

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The use of Inertial Measurement Units (IMUs) for spatial gait analysis has opened the door to unconstrained measurements within the home and community. Bandwidth, cost limitations, and ease of use has historically restricted the number and location of sensors worn on the body. In this paper, we describe a four-sensor configuration of IMUs placed on the shanks and thighs that is sufficient to provide an accurate measure of temporal gait parameters, spatial gait parameters, and joint angle dynamics during ambulation. Estimating spatial gait parameters solely from gyroscope data is preferred because gyroscopes are less susceptible to sensor noise and a system comprised of only gyroscopes uses decreased bandwidth compared to a typical 9 degree-of-freedom IMU. The purpose of this study was to determine the validity of a novel method of step length estimation using gyroscopes attached to the shanks and thighs. An Inverted Pendulum Model algorithm (IPM) was proposed to calculate step length, stride length, and gait speed. The algorithm incorporates heel-strike events and average forward velocity per step to make these assessments. IMU algorithm accuracy was determined via concurrent validity with an instrumented walkway and results explained via the collision model of gait. The IPM produced accurate estimates of step length, stride length, and gait speed with a mean difference of 3 cm and an RMSE of 6.6 cm for step length, thus establishing a new approach for spatial gait parameter calculation. The lack of numerical integration in IPM makes it well suited for use in continuous monitoring applications where sensor sampling rates are restricted.

AB - The use of Inertial Measurement Units (IMUs) for spatial gait analysis has opened the door to unconstrained measurements within the home and community. Bandwidth, cost limitations, and ease of use has historically restricted the number and location of sensors worn on the body. In this paper, we describe a four-sensor configuration of IMUs placed on the shanks and thighs that is sufficient to provide an accurate measure of temporal gait parameters, spatial gait parameters, and joint angle dynamics during ambulation. Estimating spatial gait parameters solely from gyroscope data is preferred because gyroscopes are less susceptible to sensor noise and a system comprised of only gyroscopes uses decreased bandwidth compared to a typical 9 degree-of-freedom IMU. The purpose of this study was to determine the validity of a novel method of step length estimation using gyroscopes attached to the shanks and thighs. An Inverted Pendulum Model algorithm (IPM) was proposed to calculate step length, stride length, and gait speed. The algorithm incorporates heel-strike events and average forward velocity per step to make these assessments. IMU algorithm accuracy was determined via concurrent validity with an instrumented walkway and results explained via the collision model of gait. The IPM produced accurate estimates of step length, stride length, and gait speed with a mean difference of 3 cm and an RMSE of 6.6 cm for step length, thus establishing a new approach for spatial gait parameter calculation. The lack of numerical integration in IPM makes it well suited for use in continuous monitoring applications where sensor sampling rates are restricted.

KW - Clinical gait analysis

KW - Gait speed

KW - IMU

KW - Step length

KW - Stride length

UR - http://www.scopus.com/inward/record.url?scp=85036562630&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85036562630&partnerID=8YFLogxK

U2 - 10.1016/j.jbiomech.2017.11.010

DO - 10.1016/j.jbiomech.2017.11.010

M3 - Article

C2 - 29198369

AN - SCOPUS:85036562630

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290