A pneumatized anterior clinoid mimicking an aneurysm on MR imaging. Report of two cases

A. D. Gean, J. Pile-Spellman, Roberto Heros

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

The advent of magnetic resonance (MR) imaging has marked a new era in neuroimaging - particularly in terms of diminishing the need for more invasive diagnostic procedures. A cautionary note should be sounded, however, about an important limitation of standard spin-echo MR studies. Two patients were referred for angiography because MR imaging indicated the presence of a 'paraclinoid aneurysm'. In retrospect, these findings were due instead to a pneumatized anterior clinoid. Angiography could have been avoided had this pitfall been recognized, and had a gradient-echo flow-imaging protocol been utilized. This latter approach (which does not replace spin-echo imaging) is more sensitive to flowing blood and thus allows differentiation of an air space from a nonthrombosed aneurysm.

Original languageEnglish
Pages (from-to)128-132
Number of pages5
JournalJournal of Neurosurgery
Volume71
Issue number1
StatePublished - Jan 1 1989
Externally publishedYes

Fingerprint

Aneurysm
Magnetic Resonance Imaging
Angiography
Neuroimaging
Magnetic Resonance Spectroscopy
Air

ASJC Scopus subject areas

  • Clinical Neurology
  • Neuroscience(all)

Cite this

A pneumatized anterior clinoid mimicking an aneurysm on MR imaging. Report of two cases. / Gean, A. D.; Pile-Spellman, J.; Heros, Roberto.

In: Journal of Neurosurgery, Vol. 71, No. 1, 01.01.1989, p. 128-132.

Research output: Contribution to journalArticle

@article{e7036ff457304a1284b5be97d18ada26,
title = "A pneumatized anterior clinoid mimicking an aneurysm on MR imaging. Report of two cases",
abstract = "The advent of magnetic resonance (MR) imaging has marked a new era in neuroimaging - particularly in terms of diminishing the need for more invasive diagnostic procedures. A cautionary note should be sounded, however, about an important limitation of standard spin-echo MR studies. Two patients were referred for angiography because MR imaging indicated the presence of a 'paraclinoid aneurysm'. In retrospect, these findings were due instead to a pneumatized anterior clinoid. Angiography could have been avoided had this pitfall been recognized, and had a gradient-echo flow-imaging protocol been utilized. This latter approach (which does not replace spin-echo imaging) is more sensitive to flowing blood and thus allows differentiation of an air space from a nonthrombosed aneurysm.",
author = "Gean, {A. D.} and J. Pile-Spellman and Roberto Heros",
year = "1989",
month = "1",
day = "1",
language = "English",
volume = "71",
pages = "128--132",
journal = "Journal of Neurosurgery",
issn = "0022-3085",
publisher = "American Association of Neurological Surgeons",
number = "1",

}

TY - JOUR

T1 - A pneumatized anterior clinoid mimicking an aneurysm on MR imaging. Report of two cases

AU - Gean, A. D.

AU - Pile-Spellman, J.

AU - Heros, Roberto

PY - 1989/1/1

Y1 - 1989/1/1

N2 - The advent of magnetic resonance (MR) imaging has marked a new era in neuroimaging - particularly in terms of diminishing the need for more invasive diagnostic procedures. A cautionary note should be sounded, however, about an important limitation of standard spin-echo MR studies. Two patients were referred for angiography because MR imaging indicated the presence of a 'paraclinoid aneurysm'. In retrospect, these findings were due instead to a pneumatized anterior clinoid. Angiography could have been avoided had this pitfall been recognized, and had a gradient-echo flow-imaging protocol been utilized. This latter approach (which does not replace spin-echo imaging) is more sensitive to flowing blood and thus allows differentiation of an air space from a nonthrombosed aneurysm.

AB - The advent of magnetic resonance (MR) imaging has marked a new era in neuroimaging - particularly in terms of diminishing the need for more invasive diagnostic procedures. A cautionary note should be sounded, however, about an important limitation of standard spin-echo MR studies. Two patients were referred for angiography because MR imaging indicated the presence of a 'paraclinoid aneurysm'. In retrospect, these findings were due instead to a pneumatized anterior clinoid. Angiography could have been avoided had this pitfall been recognized, and had a gradient-echo flow-imaging protocol been utilized. This latter approach (which does not replace spin-echo imaging) is more sensitive to flowing blood and thus allows differentiation of an air space from a nonthrombosed aneurysm.

UR - http://www.scopus.com/inward/record.url?scp=0024355079&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024355079&partnerID=8YFLogxK

M3 - Article

C2 - 2738631

AN - SCOPUS:0024355079

VL - 71

SP - 128

EP - 132

JO - Journal of Neurosurgery

JF - Journal of Neurosurgery

SN - 0022-3085

IS - 1

ER -