A novel retrograde laser extraction technique using a transatrial approach an alternative for complex lead extractions

Yasser Rodriguez, Juan D. Garisto, Roger Carrillo

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Background-The use of percutaneous lead extraction techniques in a patient with extracardiac or protruding atrial leads could have disastrous consequences. Traditionally, the management of these patients has included a median sternotomy. We describe a minimally invasive technique that involves a transatrial, retrograde laser lead extraction using a video-assisted thoracoscopic approach. Methods and Results-Between January 2004 and June 2009, 14 patients with severed leads at the clavicle and extracardiac leads or lead-caused erosions of the atrial wall were identified through chest radiograph and CT scan. There were 9 men and 5 women aged 19 to 91 years (mean age, 69.71±20.67 years). Ten devices were pacemakers, and 4 were defibrillators. Indications for extraction were 12 infections and 2 malfunctions. Mean ejection fraction was 42±17.67% (range, 10% to 65%). Time of implanted leads was 93.69±51.88 months (range, 33 to 213 months). Laser sheaths size were 12 F (7.1%), 14 F (85.7%), and 16 F (7.1%). A right-side thoracoscopy was performed under general anesthesia. A retrograde laser sheath maneuver was performed, freeing the lead from any adhesions. The lead was removed and the incision closed. One patient experienced a pleural effusion. There was no mortality, and all patients were alive and well at 1-month follow-up. Conclusions-Transatrial, retrograde laser lead extraction is a safe and effective procedure. This procedure may provide an excellent alternative to open sternotomy.

Original languageEnglish
Pages (from-to)501-505
Number of pages5
JournalCirculation: Arrhythmia and Electrophysiology
Volume4
Issue number4
DOIs
StatePublished - Aug 1 2011

Fingerprint

Lasers
Sternotomy
Thoracoscopy
Clavicle
Defibrillators
Pleural Effusion
General Anesthesia
Lead
Thorax
Equipment and Supplies
Mortality
Infection

Keywords

  • Defibrillators implantable
  • Lasers
  • Pacemakers
  • Thoracoscopy

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)
  • Medicine(all)

Cite this

A novel retrograde laser extraction technique using a transatrial approach an alternative for complex lead extractions. / Rodriguez, Yasser; Garisto, Juan D.; Carrillo, Roger.

In: Circulation: Arrhythmia and Electrophysiology, Vol. 4, No. 4, 01.08.2011, p. 501-505.

Research output: Contribution to journalArticle

@article{3c19c45b5a8f4033b7e021bdcb153a94,
title = "A novel retrograde laser extraction technique using a transatrial approach an alternative for complex lead extractions",
abstract = "Background-The use of percutaneous lead extraction techniques in a patient with extracardiac or protruding atrial leads could have disastrous consequences. Traditionally, the management of these patients has included a median sternotomy. We describe a minimally invasive technique that involves a transatrial, retrograde laser lead extraction using a video-assisted thoracoscopic approach. Methods and Results-Between January 2004 and June 2009, 14 patients with severed leads at the clavicle and extracardiac leads or lead-caused erosions of the atrial wall were identified through chest radiograph and CT scan. There were 9 men and 5 women aged 19 to 91 years (mean age, 69.71±20.67 years). Ten devices were pacemakers, and 4 were defibrillators. Indications for extraction were 12 infections and 2 malfunctions. Mean ejection fraction was 42±17.67{\%} (range, 10{\%} to 65{\%}). Time of implanted leads was 93.69±51.88 months (range, 33 to 213 months). Laser sheaths size were 12 F (7.1{\%}), 14 F (85.7{\%}), and 16 F (7.1{\%}). A right-side thoracoscopy was performed under general anesthesia. A retrograde laser sheath maneuver was performed, freeing the lead from any adhesions. The lead was removed and the incision closed. One patient experienced a pleural effusion. There was no mortality, and all patients were alive and well at 1-month follow-up. Conclusions-Transatrial, retrograde laser lead extraction is a safe and effective procedure. This procedure may provide an excellent alternative to open sternotomy.",
keywords = "Defibrillators implantable, Lasers, Pacemakers, Thoracoscopy",
author = "Yasser Rodriguez and Garisto, {Juan D.} and Roger Carrillo",
year = "2011",
month = "8",
day = "1",
doi = "10.1161/CIRCEP.111.963462",
language = "English",
volume = "4",
pages = "501--505",
journal = "Circulation: Arrhythmia and Electrophysiology",
issn = "1941-3149",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - A novel retrograde laser extraction technique using a transatrial approach an alternative for complex lead extractions

AU - Rodriguez, Yasser

AU - Garisto, Juan D.

AU - Carrillo, Roger

PY - 2011/8/1

Y1 - 2011/8/1

N2 - Background-The use of percutaneous lead extraction techniques in a patient with extracardiac or protruding atrial leads could have disastrous consequences. Traditionally, the management of these patients has included a median sternotomy. We describe a minimally invasive technique that involves a transatrial, retrograde laser lead extraction using a video-assisted thoracoscopic approach. Methods and Results-Between January 2004 and June 2009, 14 patients with severed leads at the clavicle and extracardiac leads or lead-caused erosions of the atrial wall were identified through chest radiograph and CT scan. There were 9 men and 5 women aged 19 to 91 years (mean age, 69.71±20.67 years). Ten devices were pacemakers, and 4 were defibrillators. Indications for extraction were 12 infections and 2 malfunctions. Mean ejection fraction was 42±17.67% (range, 10% to 65%). Time of implanted leads was 93.69±51.88 months (range, 33 to 213 months). Laser sheaths size were 12 F (7.1%), 14 F (85.7%), and 16 F (7.1%). A right-side thoracoscopy was performed under general anesthesia. A retrograde laser sheath maneuver was performed, freeing the lead from any adhesions. The lead was removed and the incision closed. One patient experienced a pleural effusion. There was no mortality, and all patients were alive and well at 1-month follow-up. Conclusions-Transatrial, retrograde laser lead extraction is a safe and effective procedure. This procedure may provide an excellent alternative to open sternotomy.

AB - Background-The use of percutaneous lead extraction techniques in a patient with extracardiac or protruding atrial leads could have disastrous consequences. Traditionally, the management of these patients has included a median sternotomy. We describe a minimally invasive technique that involves a transatrial, retrograde laser lead extraction using a video-assisted thoracoscopic approach. Methods and Results-Between January 2004 and June 2009, 14 patients with severed leads at the clavicle and extracardiac leads or lead-caused erosions of the atrial wall were identified through chest radiograph and CT scan. There were 9 men and 5 women aged 19 to 91 years (mean age, 69.71±20.67 years). Ten devices were pacemakers, and 4 were defibrillators. Indications for extraction were 12 infections and 2 malfunctions. Mean ejection fraction was 42±17.67% (range, 10% to 65%). Time of implanted leads was 93.69±51.88 months (range, 33 to 213 months). Laser sheaths size were 12 F (7.1%), 14 F (85.7%), and 16 F (7.1%). A right-side thoracoscopy was performed under general anesthesia. A retrograde laser sheath maneuver was performed, freeing the lead from any adhesions. The lead was removed and the incision closed. One patient experienced a pleural effusion. There was no mortality, and all patients were alive and well at 1-month follow-up. Conclusions-Transatrial, retrograde laser lead extraction is a safe and effective procedure. This procedure may provide an excellent alternative to open sternotomy.

KW - Defibrillators implantable

KW - Lasers

KW - Pacemakers

KW - Thoracoscopy

UR - http://www.scopus.com/inward/record.url?scp=80054017258&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80054017258&partnerID=8YFLogxK

U2 - 10.1161/CIRCEP.111.963462

DO - 10.1161/CIRCEP.111.963462

M3 - Article

C2 - 21566242

AN - SCOPUS:80054017258

VL - 4

SP - 501

EP - 505

JO - Circulation: Arrhythmia and Electrophysiology

JF - Circulation: Arrhythmia and Electrophysiology

SN - 1941-3149

IS - 4

ER -